General-purpose Relay MY Versatile, Multi-featured, Miniature Power Relay for Sequence Control and Power Switching Applications • Models with lockable test buttons now available. • Multiple features available, including operation indicators (mechanical and LED indicators), lockable test button, built-in diode and CR (surge suppression), bifurcated contacts, etc. • Environment-friendly cadmium-free contacts. • Wide range of Sockets (PY, PYF Series) and optional parts. • Max. Switching Current: 2-pole: 10 A, 4-pole: 5 A • Provided with nameplate. • RoHS Complaint. LR Ordering Information ■ Relays Standard Coil Polarity Type Contact form Model Plug-in socket/solder terminals Standard With built-in diode (DC only) With built-in CR (220/240 VAC, 110/120 VAC only) Standard with LED indicator With LED indicator and lockable test button Without LED indicator DPDT MY2N MY2IN MY2 4PDT MY4N MY4IN MY4 4PDT (bifurcated) MY4ZN MY4ZIN MY4Z DPDT MY2N-D2 MY2IN-D2 --- 4PDT MY4N-D2 MY4IN-D2 --- 4PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- DPDT MY2N-CR MY2IN-CR --- 4PDT MY4N-CR MY4IN-CR --- 4PDT (bifurcated) MY4ZN-CR MY4ZIN-CR --- Reverse Coil Polarity Type Contact form Model Plug-in socket/solder terminals Standard (DC only) With built-in diode (DC only) With LED indicator With LED indicator and lockable test button DPDT MY2N1 MY2IN1 4PDT MY4N1 MY4IN1 4PDT (bifurcated) MY4ZN1 MY4ZIN1 MY2IN1-D2 DPDT MY2N1-D2 4PDT MY4N1-D2 MY4IN1-D2 4PDT (bifurcated) MY4ZN1-D2 MY4ZIN1-D2 Note: 1. When ordering, add the rated coil voltage to the model number(s), followed by “(S)”. Rated coil voltages are given in the coil ratings table. Example: MY2 AC12(S) ↑ Rated coil voltage 2. Arc barrier standard on all four-pole relays. 3. Other models also available, such as, three-pole versions, flangemount, PCB, etc. Contact your Omron Representative for details. General-purpose Relay MY 259 Specifications ■ Coil Ratings Rated voltage Rated current 50 Hz 60 Hz AC 6 V* 214.1 mA 12 V 106.5 mA DC Coil resistance Inductance (reference value) Must operate Arm. OFF Arm. ON % of rated voltage 183 mA 12.2 Ω 0.04 H 0.08 H 80% max. 30% min. 110% 91 mA 46 Ω 0.17 H 0.33 H 24 V 53.8 mA 46 mA 180 Ω 0.69 H 1.30 H 48/50 V* 24.7/ 25.7 mA 21.1/ 22.0 mA 788 Ω 3.22 H 5.66 H 110/120 V 9.9/10.8 mA 8.4/9.2 mA 4,430 Ω 19.20 H 32.1 H 220/240 V 4.8/5.3 mA 18,790 Ω 83.50 H 136.4 H 6 V* 151 mA 39.8 Ω 0.17 H 0.33 H 12 V 75 mA 160 Ω 0.73 H 1.37 H 4.2/4.6 mA 24 V 37.7 mA 636 Ω 3.20 H 5.72 H 48 V* 18.8 mA 2,560 Ω 10.60 H 21.0 H 100/110 V 9.0/9.9 mA 11,100 Ω 45.60 H 86.2 H Must release Max. voltage Power consumption (approx.) 1.0 to 1.2 VA (60 Hz) 0.9 to 1.1 VA (60 Hz) 10% min. 0.9 W Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for rated currents and ±15% for DC coil resistance. 2. Performance characteristic data are measured at a coil temperature of 23°C. 3. AC coil resistance and impedance are provided as reference values (at 60 Hz). 4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder resistor if required. 5. Rated voltage denoted by “*” will be manufactured upon request. Ask your OMRON representative. ■ Contact Ratings Item 2-pole 4-pole 4-pole (bifurcated) Resistive load (cosφ = 1) Inductive load (cosφ = 0.4, L/R = 7 ms) Resistive load Inductive load (cosφ = 1) (cosφ = 0.4, L/R = 7 ms) Resistive load (cosφ = 1) Inductive load (cosφ = 0.4, L/R = 7 ms) Rated load 5 A, 250 VAC 5 A, 30 VDC 2 A, 250 VAC 2 A, 30 VDC 3 A, 250 VAC 3 A, 30 VDC 0.8 A, 250 VAC 1.5 A, 30 VDC 3 A, 250 VAC 3 A, 30 VDC 0.8 A, 250 VAC 1.5 A, 30 VDC Carry current 10 A (see note) 500 VA 150 W 1,250 VA 150 W 500 VA 150 W 5 A (see note) Max. switching 250 VAC voltage 125 VDC 250 VAC 125 VDC Max. switching 10 A current 5A Max. switching 2,500 VA capacity 300 W Min. permissible load* 1,250 VA 300 W 1,250 VA 150 W 5 VDC, 1 mA 1 VDC, 1 mA * Reference value. Note: Do not exceed the carry current of a Socket in use. 260 General-purpose Relay MY 1 VDC, 100 μA ■ Characteristics Contact resistance 100 mΩ max. Operate time 20 ms max. Release time 20 ms max. Max. operating frequency Mechanical 18,000 operations/hr Electrical 1,800 operations/hr (under rated load) Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric withstand voltage 2,000 VAC, 50/60 Hz for 1.0 min (1,000 VAC between contacts of same polarity) Vibration resistance Destruction:10 to 55 Hz, 1.0 mm double amplitude Malfunction:10 to 55 Hz, 1.0 mm double amplitude Shock resistance Destruction:1,000 m/s2 (approx. 100G) Malfunction:200 m/s2 (approx. 20G) Life expectancy See the following table. Ambient temperature Operating -55°C to 70°C (-67°F to 158°F) with no icing (see note) Ambient humidity Operating 5% to 85% RH Weight Approx. 35 g Note: The values given above are initial values. ■ Life Expectancy Characteristics Pole Mechanical life (at 18,000 operations/hr) Electrical life (at 1,800 operations/hr under rated load) 2-pole AC:50,000,000 operations min. DC:100,000,000 operations min. 500,000 operations min. 4-pole 4-pole (bifurcated) 20,000,000 operations min. 100,000 operations min. 200,000 operations min. ■ Approved Standards VDE, UL, CSA, IMQ, CE ■ Precautions Connections Do not reverse polarity when connecting DC-operated Relays with built-in diodes or indicators or high-sensitivity DC-operated Relays. Mounting Whenever possible, mount Relays so that it is not subject to vibration or shock in the same direction as that of contact movement. General-purpose Relay MY 261 Engineering Data ■ Maximum Switching Power AC resistive load AC inductive load (cosφ=0.4) DC resistive load Switching current (A) MY4, MY4Z Switching current (A) MY2 AC resistive load AC inductive load (cosφ=0.4) DC resistive load DC inductive load (L/R=7 ms) DC inductive load (L/R=7 ms) Switching voltage (V) Switching voltage (V) ■ Endurance MY2 (Inductive Loads) Endurance (x10 3operations) Endurance (x10 3 operations) MY2 (Resistive Loads) 10000 5000 3000 250 VAC 1000 500 300 30 VDC 30 VDC 250 VAC 100 10000 5000 3000 250 VAC 1000 500 300 30 VDC 30 VDC 250 VAC 100 50 30 50 30 10 10 Switching current (A) MY4 (Resistive Loads) MY4 (Inductive Loads) Endurance (x10 3 operations) Endurance (x10 3 operations) Switching current (A) 10000 5000 3000 250 VAC 1000 500 300 30 VDC 30 VDC 100 250 VAC 50 30 10 5000 3000 30 VDC 1000 500 300 30 VDC 250 VAC 100 50 30 250 VAC 10 Switching current (A) 262 10000 General-purpose Relay MY Switching current (A) MY4Z (Inductive Loads) 10000 5000 3000 1000 250 VAC 500 300 30 VDC 100 50 30 30 VDC 250 VAC 10 Endurance (x10 3operations) Endurance (x10 3 operations) MY4Z (Resistive Loads) 10000 5000 3000 1000 30 VDC 500 300 30 VDC 100 50 30 250 VAC 250 VAC 10 Switching Current (A) Switching Current (A) General-purpose Relay MY 263 Dimensions Note: All units are in millimeters unless otherwise indicated. ■ 2-Pole Models MY2N 2.6 Eight, 1.2 dia. × 2.2 long holes 0.5 28 max. 6.4 36 max. 21.5 max. ■ 4-Pole Models MY4N 2.6 Eight, 1.2 dia. × 2.2 long holes 0.5 28 max. 36 max. 6.4 21.5 max. ■ Models with Test Button MY2IN 2.6 Eight, 1.2 dia. × 2.2 long holes 6.3 8 14.2 80.5 5 28 max. 36 max. 21.5 max. MY4IN 2.6 Fourteen, 1.2 dia. × 2.2 long holes 0.5 6.3 8 14.2 264 General-purpose Relay MY 80.5 5 28 max. 36 max. <1.417> 6.4 21.5 max. ■ Terminal Arrangement/Internal Connections (Bottom View) MY2 MY4(Z) MY2N/MY2IN (AC Models) MY2N/MY2IN (DC Models) MY2N-D2/MY2IN-D2 (DC Models Only) MY2N-CR/MY2IN-CR (AC Models Only) MY2N1/MY2IN1 (DC Models Only) MY2N1-D2/MY2IN1-D2 (DC Models Only) MY4(Z)N/MY4(Z)IN (AC Models) MY4(Z)N/MY4(Z)IN (DC Models) MY4(Z)N-D/MY4(Z)IN-D2 (DC Models Only) MY4(Z)N-CR/MY4(Z)IN-CR (AC Models Only) MY4(Z)N1/MY4(Z)IN1 (DC Models Only) MY4(Z)N1-D2/MY4(Z)N1-D2 (DC Models Only) General-purpose Relay MY 265 Accessories (order separately) ■ Track-mounted Screwless Clamp Terminal Sockets Item Model 4-pole 2-pole Socket PYF14S PYF08S Clip & release lever PYCM-14S PYCM-08S Nameplate R99-11 Nameplate for MY Socket bridge PYDM-14SR PYDM-14SB PYDM-08SR PYDM-08SB Note: For complete specifications, see the datasheet at Omron's Knowledge Center on our website: www.knowledge.omron.com. ■ Sockets Poles 2 Front-connecting Back-connecting socket socket Solder terminals (DIN-track/screw mounting) Without clip With clip PCB terminals PYF08A-E PY08 PY08-Y1 PY08-02 PY14 PY14-Y1 PY14-02 PYF08A-N 4 PYF14A-E PYF14A-N ■ Socket Specifications Item Pole Model Carry current Dielectric withstand voltage Insulation resistance (see note 2) Screwless clamp terminal socket 2 PYF08S 10 A 2,000 VAC, 1 min Less than 1,000 MΩ 4 PYF14S 5A Track-mounted socket 2 2,000 VAC, 1 min 1,000 MΩ min. 1,500 VAC, 1 min 100 MΩ min. 4 Back-connecting socket 2 PYF08A-E 7A PYF08A-N (see note 3) 7 A (see note 4) PYF14A-E 5A PYF14A-N (see note 3) 5 A (see note 4) PY08(-Y1) 7A PY08-02 4 PY14(-Y1) 3A PY14-02 Note: 1. 2. 3. 4. 5. The values given above are initial values. The values for insulation resistance were measured at 500 V at the same place as the dielectric strength. The maximum operating ambient temperature for the PYF08A-N and PYF14A-N is 55°C. When using the PYF08A-N or PYF14A-N at an operating ambient temperature exceeding 40°C, reduce the current to 60%. The MY2(S) can be used at 70°C with a carry current of 7 A. ■ Socket Hold-down Clip Pairing Relay type Poles Without 2-pole test button 2 Without 2-pole test button 4 2-pole test button 2 266 Front-connecting socket (DIN-track/screw mounting) Back-connecting socket Socket Clip Socket Clip Socket Clip PYF08A-E PYC-A1 PY08 PYC-P PYC-P2 PY08-02 PYC-P PYC-P2 PYC-A1 PY14 PYC-P PYC-P2 PY14-02 PYC-P PYC-P2 PYC-E1 PY08 PYC-P2 PY08-02 PYC-P2 Solder terminals PYF08A-N PYF14A-E PYF14A-N PYF08A-E PYF08A-N General-purpose Relay MY PCB terminals ■ Mounting Plates for Sockets Socket model For 1 socket For 18 sockets For 36 sockets PY08, PY14 PYP-1 PYP-18 PYP-36 Note: PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of Sockets. ■ DIN Rail Track and Accessories Description Model Mounting rail (length = 500 mm) PFP-50N Mounting rail (length = 1,000 mm) PFP-100N, PFP-100N2 End Plate PFP-M Spacer PFP-S General-purpose Relay MY 267 ■ Dimensions Unit: mm (inch) Socket Dimensions PYF08A-E Terminal arrangement/ internal connections (top view) Mounting holes Two, M3, M4, or 4.5-dia. holes Two, 4.2 x 5 mounting holes Eight, M3 x 8 sems screws 72 max. (TOP VIEW) 23 max. 31 max. PYF14A-E Two, 4.2 x 5 mounting holes Note: Track mounting is also possible. Refer to page 12 for supporting tracks. Two, M3, M4, or 4.5-dia. holes Fourteen, M3 x 8 sems screws 72 max. (TOP VIEW) Note: Track mounting is also possible. Refer to page 12 for supporting tracks. 29.5 max. 31 max. PY08/PY08-Y1 (See note) Eight, 3 x 1.2 elliptical holes 25.5 max. 29.5 max. 20 max. 42 max. 24 max. Note: The PY08-Y1 includes sections indicated by dotted lines. PY08-02 25.5 max. 29.5 max. 22 max. 16.5 max. 268 General-purpose Relay MY Eight, 1.3-dia. holes Socket Dimensions PYF08A-N Terminal arrangement/ internal connections (top view) Mounting holes 22 max. 4 1 42 12 8 5 44 14 42 4 44 8 12 1 14 5 3.0 dia. 3.5 dia. or M3 18.7 67 max. 73 PYF-08A-N 41 11 12 9 A2 A2 A1 14 14 13 12 9 41 11 Note: Track mounting is also possible. Refer to page 12 for supporting tracks. 14 14 13 A2 A2 A1 30 max. PYF14A-N 4 3 2 1 42 32 22 12 8 7 6 5 44 34 24 14 42 4 44 8 32 3 34 7 22 2 24 6 12 1 14 5 Two, 4.5 dia. or M4 67 max. 26 PYF-14A-N 41 31 21 11 12 11 10 9 A2 A2 A1 14 14 13 73 12 11 10 9 41 31 21 11 30 max. 29.5 max. PY14/PY14-Y1 (See note) 14 14 A2 A2 13 A1 Note: Track mounting is also possible. Refer to page 12 for supporting tracks. Fourteen, 3 x 1.2 elliptical holes 25.5 max. 29.5 max. 42 max. 20 max. 24 max. Note: The PY14-Y1 includes sections indicated by dotted lines. PY14-02 25.5 max. 29.5 max. 22 max. 16.5 max. Fourteen, 1.3-dia. holes Note: Use a panel with plate thickness of 1 to 2 mm for mounting the Sockets. General-purpose Relay MY 269 Socket Dimensions Terminal arrangement/ internal connections (top view) PYF14S Mounting height (with lever) 36.5 max. 72.6 typ. 31 max. 28.6 Note: Track mounting only. Note: Pole-2 and pole-3 cannot be used with the MY2 type. Use pole-1 (terminal numbers 11, 14, 12) and pole-4 (terminal numbers 41, 44, 42). 85 max. 38.2 max. 36.5 max. PYF08S 73.6 typ. 23.2 max. 28.6 Note: Track mounting only. 85 max. (5.3) Socket Bridge Insulating coating L 1.4 dia. conductor (See note 1.) Model number PYDM-14SR Length L (mm) 27.5±0.3 PYDM-14SB PYDM-08SR Color of insulating coating Red Blue 19.7±0.3 PYDM-08SB Red Blue Note: 1. The relationship between the model number, the length L, and the color of the insulating coating is shown above. 2. The insulating coating must be able to withstand a voltage of 1,500 V for 1 minute. Use either PE or PA as the material of the insulating coating. 270 General-purpose Relay MY Item Characteristic Rated ON current 10 A Rated insulation voltage 250 VAC Temperature rise 35°C max. Dielectric strength 1,500 VAC for 1 minute Ambient operating temperature -55 to 70°C 3. The positions of the ends of the insulating coating must not vary more than 0.5 mm. 4. The characteristics of the socket bridge are shown above. ■ Clip and Release Levers PYCM-14S PYF14S Lever PYCM-08S PYF08S Lever 16 typ. 26.5 typ. 21.5 typ. 28 typ. 6 typ. 54.4 typ. 4.1 typ. 52.5 typ. 5.4 typ. 32.7 typ. 29.6 typ. 6.41 typ. 3 typ. ■ Hold-down Clips PYC-A1 PYC-A1 (2 (2 pcs pcs per per set) set) PYC-E1 PYC-E1 (2 pcs perper set)set) (2 pcs 36.3 36.3 5.75 4.5 4.5 4.25 4.5±0.1 1.2 PYC-P PYC-P PYC-P2 PYC-P2 5 10 29 max. 28 3.3 38.5 General-purpose Relay MY 271 ■ Mounting Plates for Back-connecting Sockets PYP-1 PYP-1 PYP-36 PYP-36 Two, 3.4-dia. holes 72 elliptical holes t=1.6 PYP-18 PYP-18 72 elliptical holes ■ Mounting Track and Accessories DIN Rail Track PFP-50N/PFP-100N 7.3±0.15 4.5 35±0.3 27±0.15 1 15 25 10 25 25 1000 (500) * 10 15 (5) 25 Note: The figure in the parentheses is for PFP-50N. PFP-100N2 16 4.5 35±0.3 27 25 15 10 25 1000 25 10 25 15 End Plate PFP-M 10 M4 x 8 pan head screw 6.2 1.8 1 50 1.8 11.5 10 M4 spring washer 272 General-purpose Relay MY 1.3 4.8 35.5 35.3 24 1 29.2 1.5 Spacer PFP-S 16 12 5 34.8 44.3 16.5 ■ Approved Standards VDE Recognitions (File No. 112467UG, IEC 255, VDE 0435) No. of poles Coil ratings Contact ratings Operations 2 6, 12, 24, 48/50, 100/110 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110, 125 VDC 10 A, 250 VAC (cosφ=1) 10 A, 30 VDC (L/R=0 ms) 10 x 103 5 A, 250 VAC (cosφ=1) 5 A, 30 VDC (L/R=0 ms) 100 x 103 MY4Z AC; 50 x 103 4 UL Recognized (File No. 41515) No. of poles Coil ratings Contact ratings Operations 2 6 to 240 VAC 6 to 125 VDC 10 A, 30 VDC (general purpose), 40°C 10 A, 250 VAC (general purpose), 40°C 6 x 103 4 5 A, 30 VDC (general purpose), 40°C (Same polarity) 5 A, 250 VAC (general purpose), 40°C (Same polarity) CSA Certified (File No. LR31928) No. of poles Coil ratings Contact ratings Operations 2 6 to 240 VAC 6 to 125 VDC 10 A, 30 VDC 10 A, 250 VAC 6 x 103 4 5 A, 250 VAC (same polarity) 5 A, 30 VDC (same polarity) IMQ (File No. EN013 to 016) No. of poles Coil ratings Contact ratings Operations 2 6, 12, 24, 48/50, 100/110 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110, 125 VDC 10 A, 30 VDC 10 A, 250 VAC 10 x 103 5 A, 250 VAC 5 A, 30 VDC 100 x 103 MY4Z AC; 50 x 103 4 LR Recognitions (File No. 98/10014) No. of poles Coil ratings Contact ratings Operations 2 6 to 240 VAC 6 to 125 VDC 10 A, 250 VAC (resistive) 2 A, 250 VAC (PF0.4) 10 A, 30 VDC (resistive) 2 A, 30 VDC (L/R=7 ms) 50 x 103 5 A, 250 VAC (resistive) 0.8 A, 250 VAC (PF0.4) 5 A, 30 VDC (resistive) 1.5 A, 30 VDC (L/R=7 ms) 50 x 103 4 General-purpose Relay MY 273 SEV Listings (File No. 99.5 50902.01) No. of poles Coil ratings Contact ratings Operations 2 6 to 240 VAC 6 to 125 VDC 10 A, 250 VAC 10 A, 30 VDC 10 x 103 5 A, 250 VAC 5 A, 30 VDC 100 x 103 MY4Z AC; 50 x 103 4 Note: 1. The rated values approved by each of the safety standards (eg., UL, CSA, VDE, and SEV) may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change. PYF-S Installation Notes ■ Tools A flat-blade screwdriver should be used to mount the cables. Applicable Screwdriver ● Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.) ● Flat-blade, Parallel-tip 2.5 dia. (3.0 mm max.) ● Flat-blade, Flared-tip Cannot be used. Examples: FACOM AEF.2.5 × 75E VESSEL No. 9900-(-)2.5 × 75 WAGO 210-119 WIHA 260/2.5 × 40 (AEF. 3 × 75E) (No. 9900-(-)3 × 100) (260/3 × 50) *Chamfering the tip of the driver improves insertion when used as an exclusive tool. ■ Applicable Wires Applicable Wire Sizes 0.2 to 1.5 mm2, AWG24 to AWG16 Applicable Wire Type Solid wires, stranded wires, flexible wires, or wires with ferules can be used. (See note 1.) < 2.2 ≤ Diameter D (mm) ≤ 3.2 (3.5: see note 2.) Note: 1. If the overall diameter of the wire is less than 2.2 mm, do not insert the wire past the conductor. Refer to the following diagrams. Conductor diameter d (mm) or length of sides a and b (mm) ≤ 1.9 2. If the overall diameter of the wire is over 3.2 mm, it will be difficult to use double wiring. Wires with Ferules 274 General-purpose Relay MY Examples of Applicable Wires (Confirmed Using Catalog Information) Type of wire Conductor type Equipment wire 2491X Flexible See note 1, above. Recommended wire sizes See note 2, above. BS6004 Solid Switchgear BS6231 Solid Switchgear BS6231 Flexible Tri-rated control and switchgear Flexible 0.5, 0.75, 1.0, 1.5 mm Conduit Stranded 1.5 mm2 UL1007 Flexible UL1015 Flexible UL1061 Flexible 18AWG UL1430 Flexible 18AWG 0.5, 0.75, 1.0 mm2 1.5 mm2 1.0 mm2 1.5 mm2 0.5 mm2 0.5, 0.75 mm 18AWG 2 1.0 mm2 2 16AWG 18AWG, 16AWG 16AWG ■ Wiring Use wires of the applicable sizes specified above. The length of the exposed conductor should be 8 to 9 mm. 8 to 9 mm Fig. 1 Exposed Conductor Length 2. Insert the exposed conductor into the wire connection hole. Use the following wiring procedure. 1. Insert the specified screwdriver into the release hole located beside the wire connection hole where the wire is to be inserted. Insert Wire connection holes Release holes 3. Pull out the screwdriver. Fig. 2 Wire Connection Holes and Release Holes Wire connection hole Pull out Note: Use no more than 2 wires per terminal, 1 wire per hole. Release hole Insert Screwdriver Fig. 3 Section A-A of Fig. 2 General-purpose Relay MY 275 ■ Precautions Precautions for Connection General Precautions • Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components (e.g., deformation of the coil spring or cracks in the housing) or cause deterioration of insulation. • Do not insert the screwdriver at an angle. Doing so may break the side of socket and result in a short-circuit. • Use the clip to prevent relays floating or falling out of the socket. • Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performance. • Confirm that the socket is securely attached to the mounting track before wiring. If the socket is mounted insecurely it may fall and injure the operator. • Ensure that the socket is not charged during wiring and maintenance. Not doing so may result in electric shock. • Do not pour water or cleansing agents on the product. Doing so may result in electric shock. • Do not use the socket in locations subject to solvents or alkaline chemicals. • Do not use the socket in locations subject to ultraviolet light (e.g., direct sunlight). Doing so may result in markings fading, rust, corrosion, or resin deterioration. • Do not dispose of the product in fire. • Do not insert two or more wires in the hole. Wires may come in contact with the spring causing a temperature rise or be subject to sparks. (There are two wiring holes for each terminal.) Removing from Mounting Rail To remove the socket from the mounting rail, insert the tip of screwdriver in the fixture rail, and move it in the direction shown below. Screwdriver • Insert the screwdriver along the hole wall as shown below. Fixture rail Screwdriver • If lubricating liquid, such as oil, is present on the tip of screwdriver, the screwdriver may fall out resulting in injury to the operator. • Insert the screwdriver into the bottom of the hole. It may not be possible to connect cables properly if the screwdriver is inserted incorrectly. 276 General-purpose Relay MY Omron Electronic Components, LLC Terms and Conditions of Sales I. GENERAL 1. Definitions: The words used herein are defined as follows. (a) Terms: These terms and conditions (b) Seller: Omron Electronic Components LLC and its subsidiaries (c) Buyer: The buyer of Products, including any end user in section III through VI (d) Products: Products and/or services of Seller (e) Including: Including without limitation 2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments, invoices, purchase orders and other documents, whether electronic or in writing, relating to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms. 3. Distributor: Any distributor shall inform its customer of the contents after and including section III of these Terms. II. SALES 1. Prices; Payment: All prices stated are current, subject to change without notice by Seller. Buyer agrees to pay the price in effect at the time the purchase order is accepted by Seller. Payments for Products received are due net 30 days unless otherwise stated in the invoice. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. 2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past due amounts owing to Seller. 3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 4. Orders: Seller will accept no order less than 200 U.S. dollars net billing. 5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer shall make remittance to Seller at the then current exchange rate most favorable to Seller; provided that if remittance is not made when due, Buyer will convert the amount to U.S. dollars at the then current exchange rate most favorable to Seller available during the period between the due date and the date remittance is actually made. 6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining any government approvals regarding the importation or sale of the Products. 7. Taxes: All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Seller or required to be collected directly or indirectly by Seller for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Seller. 8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller, Seller reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Seller may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Seller fully against all costs or expenses arising in connection therewith. 10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller: (a) All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Seller), at which point title to and all risk of loss of the Products shall pass from Seller to Buyer, provided that Seller shall retain a security interest in the Products until the full purchase price is paid by Buyer; (b) Delivery and shipping dates are estimates only; and (c) Seller will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products occurring before delivery to the carrier or any claim related to pricing or other charges must be presented in detail in writing to Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability: IT IS THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E) SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT. Buyer acknowledges that it alone has determined that the Products will meet their requirements of the intended use in all cases. Buyer must know and observe all prohibitions of use applicable to the Product/s. 2. Use with Attention: The followings are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible use of any Product, nor to imply that any use listed may be suitable for any Product: (a) Outdoor use, use involving potential chemical contamination or electrical interference. (b) Use in consumer Products or any use in significant quantities. (c) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (d) Systems, machines, and equipment that could present a risk to life or property. 3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY SELLER. 5. Programmable Products: Seller shall not be responsible for the Buyer's programming of a programmable Product. IV. WARRANTY AND LIMITATION 1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Seller (or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES, NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. 2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an amount equal to the purchase price of the Product; provided that there shall be no liability for Seller or its affiliates unless Seller's analysis confirms that the Products were correctly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Seller before shipment. 3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF THE PRODUCT ON WHICH LIABILITY IS ASSERTED. 4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. V. INFORMATION; ETC. 1. Intellectual Property: The intellectual property embodied in the Products is the exclusive property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way without the written permission of Seller. Buyer (at its own expense) shall indemnify and hold harmless Seller and defend or settle any action brought against Seller to the extent that it is based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. 2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Seller. All information and materials supplied by Seller to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. 3. Performance Data: Performance data is provided as a guide in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. 4. Change In Specifications: Product specifications and descriptions may be changed at any time based on improvements or other reasons. It is Seller’s practice to change part numbers when published ratings or features are changed, or when significant engineering changes are made. However, some specifications of the Product may be changed without any notice. 5. Errors And Omissions: The information on Seller’s website or in other documentation has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses regarding (a) export of the Products or information provided by Seller; (b) sale of Products to forbidden or other proscribed persons or organizations; (c) disclosure to noncitizens of regulated technology or information. VI. MISCELLANEOUS 1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing between Buyer and Seller shall operate as a waiver of rights by Seller. 2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent. 3. Law: These Terms are governed by Illinois law (without regard to conflict of laws). Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any dispute hereunder. 4. Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. General-purpose Relay MY Certain Precautions on Specifications and Use 1. Suitability for Use. Seller shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in Buyer's application or use of the Product. At Buyer's request, Seller will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a nonexhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iii) Use in consumer products or any use in significant quantities. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 2. Programmable Products. Seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to Seller's Warranty and Limitations of Liability. 4. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Seller representative at any time to confirm actual specifications of purchased Product. 5. Errors and Omissions. The information in this publication has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors, or omissions. 6. RoHS Compliance. Where indicated, our products currently comply, to the best of our knowledge as of the date of this publication, with the requirements of the European Union's Directive on the Restriction of certain Hazardous Substances ("RoHS"), although the requirements of RoHS do not take effect until July 2006. These requirements may be subject to change. Please consult our website for current information. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC Global - http://www.omron.com USA - http://www.components.omron.com 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. X301-E-1 06/09 General-purpose Relay Specifications subject to change without notice MY Printed in USA