N1000 and N1200 SERIES Single, dual, triple and quad output • • • • • • • • The N1000 and N1200 series are a range of systems-orientated, one to four output power supplies which provide 1000W or 1200W of continuous power at line voltages from 90VAC to 264VAC. Both series are harmonically corrected and carry world wide safety approvals. Fully enclosed, fan cooled and in the industry standard 5 x 8 x 11 inch form, the N series is an ideal choice when the economy and predictable performance of a centralized system power supply are desired. A unique dual converter architecture isolates the 5VDC logic output and the peripheral voltages. Maximum flexibility is provided as power budgets shift and change during the design cycle or as system upgrades are implemented. This overcomes a major shortfall of many system power supplies which use a single converter. To meet redundancy requirements, each output rail is isolated, individually regulated and features forced current share. System interface signals include AC and DC Good, current monitor (V1), overvoltage, OCP, overtemperature protection, remote enable, margin check and inhibit as standard. By combining robust performance and broad range, the N Series sets the standard for centralized system power supplies. [ 2 YEAR WARRANTY ] SPECIFICATION OUTPUT SPECIFICATIONS Active harmonic correction to EN61000-3-2 90VAC to 264VAC universal input Flexible output voltage configuration Two output power ratings Forced current sharing, all outputs DC OK (including LED) UL, CSA and TÜV safety approvals Industry standard 5 x 8 x 11 inch footprint All specifications are typical at nominal input, full load at 25°C unless otherwise stated (2) EMC CHARACTERISTICS Voltage adjustability Accessible at front panel Remote sense Open/reverse sense lead protection Compensates for voltage drop of up to 0.5V to the load Regulation, line or load All outputs, NL-FL at nominal line or all line variations at FL Cross regulation ±0.2%; 10mV min. 0.2% max. or 10mV between outputs Overshoot/undershoot Transient response None at turn on/off ≤2.0% max. dev., ≤200µs recovery to 1.0% Main output 25% step load change at 1A/µs Temperature coefficient 0Hz to 20MHz Overvoltage protection Reset by cycling AC Overload protection 50mV pk-pk or 1% 115 to 130% of nominal 105-115% full load All outputs Thermal protection Auto recovery EN55022/11, FCC part 15 EN55022/11, FCC part 15 EN61000-3-2 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 ±5.0% 50% to 100% load Current monitor (V1) 5VDC at full load ±0.5V INPUT SPECIFICATIONS Input voltage range 90 to 264VAC Input frequency range 47Hz to 63Hz Input surge current Meets IEEE std. 587.1980; 3KV ring wave Input current 120VAC, 1000W Power factor 115/230VAC, 1kW load Power up time Full load 1.0s max. Level 3 Hold-up time 90VAC, 1KW load 24ms min. Efficiency 230VAC, full load 73% Isolation voltage Input/output Input/chassis Output/output 3000VAC 1500VAC 500VAC Switching frequency 100kHz Approvals and standards EN60950, UL1950, CSA C22.2 No. 950 Weight 6.9kg (15Ibs) Size MTBF 5 x 8 x 11 inches 127 x 203.2 x 279.4 mm per MIL-HDBK-217E 100,000 hours ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient Non-operating Cooling 60CFM Relative humidity Non-condensing Altitude Operating Non-operating Vibration 5Hz to 500Hz 12A 0.995 min. Level A Level A Conforms Level 3 Level 3 Level 3 GENERAL SPECIFICATIONS Auto shutdown, AC reset Current sharing PAGE 1 Radiated emissions Conducted emissions Harmonic distortion Electrostatic discharge RF field susceptibility Electrical fast transients/bursts Surge susceptibility ±0.02%/°C Ripple and noise Short circuit protection ±10% 0°C to +50°C -15°C to +85°C Internal DC ball bearing fan 0% to 95% RH 6,000 feet max. 55,000 feet max. 2.4G rms peak MEDIUM TO HIGH POWER AC/DC POWER SUPPLIES | 1000-1200W AC/DC 1000 and 1200 Watt AC/DC high wattage power supplies with PFC MAX. OUTPUT POWER (1) OUTPUT V1 OUTPUT V2 OUTPUT V3 OUTPUT V4 VOLTAGE/CURRENT VOLTAGE/CURRENT VOLTAGE/CURRENT VOLTAGE/CURRENT MODEL NUMBER 1000W 3.3V @ 200A N1000-96-9 1000W 5.0V @ 200A N1000-96-1 1000W 5.0V @ 150A 12V @ 25A 12V @ 20A N1000-96-122 1000W 5.0V @ 150A 12V @ 30A 5.0V @10A N1000-96-121 1000W 5.0V @ 150A 12V @ 25A 12V @ 15A 5V @ 10A N1000-96-1221 1000W 5.0V @ 150A 12V @ 25A 12V @ 10V 24V @ 5.0A N1000-96-1224 1000W 5.0V @ 150A 5.0V @ 30A 12V @ 20V 12V @ 10A N1000-96-1122 1000W 5.0V @ 150A 3.3V @ 30A 12V @ 20A 12V @ 10A N1000-96-1922 1000W 5.0V @ 150A 24V @ 15A 12V @ 10A 12V @ 5.0A N1000-96-1422 1200W 2.0V @ 240A N1200-96-0 1200W 3.3V @ 240A N1200-96-9 1200W 5.0V @ 240A N1200-96-1 1200W 12V @ 100A N1200-96-2 1200W 24V @ 50A N1200-96-4 1200W 28V @ 43A N1200-96-5 1200W 48V @ 25A N1200-96-6 1200W 5.0V @ 200A 12V @ 40A N1200-96-12 1200W 5.0V @ 200A 24V @ 20A N1200-96-14 1200W 48V @ 25A 24V @ 20A N1200-96-64 1200W 5.0V @ 175A 12V @ 30A 12V @ 20A N1200-96-122 1200W 5.0V @ 175A 12V @ 35A 5V @ 20A N1200-96-121 1200W 5.0V @ 175A 12V @ 30A 24V @ 15A N1200-96-124 1200W 5.0V @ 175A 3.3V @ 40A 12V @ 20A N1200-96-192 1200W 5.0V @ 175A 12V @ 30A 12V @ 20A 5V @ 10A N1200-96-1221 1200W 5.0V @ 175A 12V @ 30A 12V @ 10A 24V @ 5A N1200-96-1224 1200W 5.0V @ 175A 15V @ 30A 15V @ 10A 5V @ 10A N1200-96-1331 1200W 5.0V @ 175A 5.0V @ 40A 12V @ 20A 12V @ 10A N1200-96-1122 1200W 5.0V @ 175A 3.3V @ 40A 12V @ 20A 12V @ 10A N1200-96-1922 1200W 5.0V @ 175A 24V @ 20A 12V @ 10A 12V @ 5A N1200-96-1422 1200W 24V @ 42A 5.0V @ 40A 12V @ 20A 12V @ 10A N1200-96-4122 International Safety Standard Approvals VDE0805/EN60950/IEC950 File No. R917062 TÜV Certificate No. R9172062 UL1950 File No. E135734 CSA C22.2 No. 950 Bulletin No. 1402C http://www.artesyn.com PAGE 2 1000-1200W AC/DC | MEDIUM TO HIGH POWER AC/DC POWER SUPPLIES 1000 and 1200 Watt AC/DC high wattage power supplies with PFC PIN NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Mechanical notes OUTPUT PIN CONNECTIONS J1 J2 + Sense (V1) (4) + Sense (V2) Current Monitor (V1) (5) - Sense (V2) Inhibit (5) Current Share (V2) - Sense (V1) (4) + Sense (V4) No Connection - Sense (V4) No Connection Current Share (V4) Current Share (5) Remote Adj. (V2) (6) (6) Remote Adj. (V1) Remote Adj. (V3) (6) (5) AC Good Remote Adj. (V4) (6) Chassis Ground Current Share (V3) Logic Ground - Sense (V3) Margin (7) + Sense (V3) No Connection N/A DC OK (5,8) N/A A AC connector is 3 position terminal block (#8 screws included), mating to #8 ring tongue terminal. B DC output is 5/16-18 studs mating to 5/16 terminal lugs. C J1 signal connector is Molex 39-30-1140 or equivalent. Mating connector is Molex 39-01-2140 or equivalent. D J2 signal connector is Molex 39-01-1120 or equivalent. Mating connector is 39-01-2120 or equivalent. E Signal connector contacts are Molex 39-00-0039 or equivalent. F Auxiliary DC output(s) are 6 position terminal block (#8 screws included) mating to #8 ring tongue terminal. G TB1 and J2 are not installed on single output models. Notes 1 2 3 4 5 6 7 8 1000W or 1200W max. power. 500/600W max. power (V2 thru V4). All outputs isolated. Specifications refer to all outputs except as noted (V1). Signal referenced to V1 output neg. sense trim. Use 20AWG or larger twisted pair. Reference to Logic Ground (Pin J1-11). See Figure 4. See Figure 3. See Figure 5. 12.13 Max. (308.10) 11.00 (279.40) 0.75 (19.05) Auxiliary Outputs (# 8 Screws) 6.750 (171.450) AC Input (# 8 Screws) ACH + v 2 - 5.00 (127.00) + v 3 - T B 1 4.00 (101.60) ACN V2 V3 TB1 and J2 are Not Installed on Single Output Models V4 + v 4 - 0.90 (22.86) V1 + _ J 2 V1 1.30 (33.02) J 1 0.50 (12.70) 8-32 X 0.29 (7.37) Deep (Max.) (4) Both Sides Main Output 5/16 - 18 Studs 50 IN-LB Torque Max. 1.13 (28.70) 2.80 (71.12) J1 5.75 (146.05) 0.90 (22.86) Pin 1 AIRFLOW 8.00 (203.2) J2 8-32 x 0.29 (7.37) Deep (Max.) (4) Top and Bottom Pin 1 ALL DIMENSIONS IN INCHES (mm) PAGE 3 MEDIUM TO HIGH POWER AC/DC POWER SUPPLIES | 1000-1200W AC/DC 1000 and 1200 Watt AC/DC high wattage power supplies with PFC FIG. 1 FIG. 2 (Ref. FIG 5) J1-P9 AC Good, J1-P14 DC OK 15V FIG. 5 AC Power Fail Signal/DC OK Timing AC Input Voltage 10K Low = Power/Output fail High = Power/Output OK External Pull-up Required Sink Current 20mA (On Voltage 0.7V) J1-P3 85Vrms 0V >10ms AC Good Flag Close to Enable >5ms DC Outputs FIG. 3 FIG. 4 Open = Nominal Voltage 5V Tie to +5V for High Margin Tie to Logic Ground (J1-11) For Low Margin. Output Voltage DC Good Flag (J1-P8) > 10K (J1-P12) Margin Sense STANDARD CONTROL SIGNALS Remote enable DC OK (See Figures 2 and 5) AC power fail signal (See Figure 5) Margin Hi/Lo (V1) (See Figure 3) Remote Adjust (See Figure 4) Current Monitor See Figure 1 Signal remains "Hi" as long as output is ±5.0% of nominal. Signal "Hi" when AC >85VAC and "Lo" when <75VAC. Allows ±5.0% change in output for system margin checking. The outputs may be remotely adjusted linearly ±10%. Analog signal indicates load current in single or parallel operation. 5±0.5VDC represents FL, resistive load 103kΩ. DS_N1000/N1200_19980401.PDF http://www.artesyn.com PAGE 4