Media Converters Repeaters and Optimizers Datasheet FD Fiber Driver® Chassis Features Models with 1, 2, 3, 4, or 16 slots Rack mounting options ¹ Wall mounting options ² Module flexibility; no slot dependency within a chassis Hot-swap support Management module compatibility ³ - fan status - power supply status - temperature status - high and low temperature limits - SNMP traps to report faults Overview The Fiber Driver® chassis is the foundation for deploying and managing the Fiber Driver media module product family. Chassis are available with one, two, three, four, and sixteen slots. AC or DC redundant power supply pairs Optional front cable management tray for NC316BU-16 chassis The three-slot (NC316BU-3), four-slot (NC316BU-4 and NC316BU-4S), sixteen-slot (NC316BU-16) and sixteen-slot Telco (NC316BU-16T) chassis can be equipped with redundant, hot-swappable AC or DC internal power supplies. The two-slot NC316BU-2 and one-slot NC316BU-1 come with a single AC or DC internal power supply. The NC316BU-1/NP and NC316BU4PMC/NP chassis are designed to host fully passive modules such as the Fiber Driver Splitter/Combiner. Because fully passive solutions require no external power source, these chassis include no power supply. ONE-SLOT CHASSIS ¹ three-slot, four-slot, and sixteen-slot models ² one-slot and two-slot models ³ two-slot, three-slot, four-slot, and sixteen-slot chassis models SIXTEEN-SLOT CHASSIS THREE-SLOT CHASSIS FOUR-SLOT CHASSIS TWO-SLOT CHASSIS SIXTEEN-SLOT TELCO 23” CHASSIS [email protected] Media Converters Repeaters and Optimizers Chassis with two, three, four and sixteen slots can accommodate a network management module. EM316NM and EM316LNXNM-OT provide monitoring of system temperature, fan status, and power supply. The one-slot chassis is suitable for unmanaged use in standalone applications. The NC316BU-2 is designed for single-module managed and two-module unmanaged standalone applications. The NC316BU-4, NC316BU-4S, and NC316BU-16 mount in 19” racks. The NC316BU-3 and NC316BU-16T, have reduced depth form-factors and front-loaded power supplies for Telco installations. These models mount in 23” racks, and the NC316BU-3 can also mount in 19” racks. Contact your nearest MRV representative for information on Fiber Driver or other products. Ordering Information REDUNDANT POWER SUPPLIES Model Description NC316-3RPSAC Redundant Power Supply for NC316BU-3/AC NC316-3RPSDC Redundant Power Supply for NC316BU-3/DC NC316-4RPSAC Redundant Power Supply for NC316BU-4/AC NC316-4RPSDC Redundant Power Supply for NC316BU-4/DC NC316BU-4SRPSAC Redundant Power Supply for NC316BU-4S/AC NC316BU-4SRPSDC Redundant Power Supply for NC316BU-4S/DC NC316-16RPSAC Redundant Power Supply for NC316BU-16/AC NC316-16RPSDC Redundant Power Supply for NC316BU-16/DC NC316-16T/DC Redundant Power Supply for NC316BU-16T/DC Ordering Information ACCESSORIES Model Description NC316RB23-3 Rack Mount Bracket for NC316BU-3/AC or -3/DC Telco Chassis; 23” NC316RB23-4 Rack Mount Bracket for NC316BU-4/AC or -4/DC Telco Chassis; 23” NC316-16BRACKET Rack Mount Bracket for 16-slot Chassis NC316RB23-16 Rack Mount Bracket for NC316BU-16/AC Chassis, 23” NC316MB-1 Wall Mount Bracket for NC316BU-1 NC316MB-2 Wall Mount Bracket for NC316BU-2 NC316BP-1 Blank Panel, Single-Slot Wide, for NC316BU NC316BP-4 Blank Panel, Four-Slot Wide, for NC316BU-16 NC316DCC DC Power Female Connector (WAGO) NC316BU-16CMT Cable Management Tray for the NC316BU-16 Chassis NC316-16DOOR Cable Management Tray and transparent door for the NC316BU-16 Chassis [email protected] Media Converters Repeaters and Optimizers Ordering Information CHASSIS Model Description Physical Dimensions (hight x width x depth) Weight NC316BU-1/AC One-slot, AC power 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 1.0 kg (2.2 lbs) NC316BU-1/DC One-slot, DC power 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 1.0 kg (2.2 lbs) NC316BU-1/AC/EU One-slot, VAC power (European version) 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 1.0 kg (2.2 lbs) NC316BU-1HP/AC One-slot, AC power 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 1.0 kg (2.2 lbs) NC316BU-1HP/DC One-slot, DC power 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 1.0 kg (2.2 lbs) NC316BU-1/NP One-slot, no power supply (passive application only) 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 1.0 kg (2.2 lbs) NC316BU-2/AC Two-slot, AC power 65 mm x 159 mm x 197 mm (2.56” x 6.26” x 7.75”) 1.4 kg (3.1 lbs) NC316BU-2/DC Two-slot, DC power 65 mm x 159 mm x 197 mm (2.56” x 6.26” x 7.75”) 1.4 kg (3.1 lbs) NC316BU-3/AC Three-slot Telco, for19” rack, AC power 44 mm x 439 mm x 203 mm (1.73” x 17.28” x 7.99”) 3.1 kg (6.8 lbs) NC316BU-3/DC Three-slot Telco, for19” rack, DC power 44 mm x 439 mm x 203 mm (1.73” x 17.28” x 7.99”) 3.0 kg (6.6 lbs) NC316BU-4/AC Four-slot, for 19” rack, AC power 44 mm x 439 mm x 434 mm (1.73” x 17.28” x 17.09”) 7.7 kg (17.0 lbs) NC316BU-4/DC Four-slot, for 19” rack, DC power 44 mm x 439 mm x 434 mm (1.73” x 17.28” x 17.09”) 7.7 kg (17.0 lbs) NC316BU-4S/AC Four-slot, for 19” rack, AC power 44 mm x 439 mm x 305 mm (1.73” x 17.28” x 12.00”) 4.5 kg (9.9 lbs) NC316BU-4S/DC Four-slot, for 19” rack, DC power 44 mm x 439 mm x 305 mm (1.73” x 17.28” x 12.00”) 4.5 kg (9.9 lbs) NC316BU4PMC/NP Non-managed, non-powered four-slot chassis for passive Mux/Demux modules 44 mm x 441 mm x 286 mm (1.73” x 17.36” x 11.26”) 4.3 kg (9.6 lbs) NC316BU-16/AC Sixteen-slot, for 19” rack, AC power 110 mm x 439 mm x 408 mm (4.33” x 17.28” x 16.06”) 8.8 kg (19.4 lbs) NC316BU-16/DC Sixteen-slot, for 19” rack, DC power 110 mm x 439 mm x 408 mm (4.33” x 17.28” x 16.06”) 8.7 kg (19.2 lbs) NC316BU-16T/DC Sixteen-slot Telco, for 23” rack, DC power 132 mm x 541 mm x 254 mm (5.20” x 21.30” x 10.00”) 8.2 kg (18.1 lbs) [email protected] Media Converters Repeaters and Optimizers Ordering Information POWER SUPPLY SPECIFICATIONS Model Nominal Input Range (VAC) Input Range (VDC)* Maximum Rating (Amps) Operating Temperature Storage Temperature Relative Humidity NC316BU-1/AC 100 - 240 @ 50/60 Hz - 0.3 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing NC316BU-1/DC - 40.5 - 57 0.5 -35 to +60°C (-31 to +140°F) -35 to +70°C (-31 to +158°F) < 85% non condensing NC316BU-1/AC/EU 100 - 240 @ 50/60 Hz - 0.3 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing NC316BU-1HP/AC 100 - 240 @ 50/60 Hz - 0.3 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing NC316BU-1HP/DC - 40.5 - 57 0.5 -40 to +65°C (-40 to +149°F) -45 to +75°C (-49 to +167°F) < 85% non condensing NC316BU-2/AC 100 - 240 @ 50/60 Hz - 0.6 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing NC316BU-2/DC - 40.5 - 57 1.0 -35 to +60°C (-31 to +140°F) -35 to +70°C (-31 to +158°F) < 85% non condensing NC316BU-3RPSAC 100 - 240 @ 50/60 Hz - 1.6 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing NC316BU-3RPSDC - 40.5 - 57 2.0 -35 to +60°C (-31 to +140°F) -35 to +70°C (-31 to +158°F) < 85% non condensing NC316BU-4RPSAC 100 - 240 @ 50/60 Hz - 4.0 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing NC316BU-4RPSDC - 40.5 - 57 2.0 -35 to +60°C (-31 to +140°F) -35 to +70°C (-31 to +158°F) < 85% non condensing NC316BU-4SRPSAC 100 - 240 @ 50/60 Hz - 1.8 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing NC316BU-4SRPSDC - 40.5 - 57 2.0 -35 to +60°C (-31 to +140°F) -35 to +70°C (-31 to +158°F) < 85% non condensing NC316BU-16RPSAC 100 - 240 @ 50/60 Hz - 3.5 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing NC316BU-16RPSDC - 40.5 - 57 5.0 or 6.5 -35 to +60°C (-31 to +140°F) -35 to +70°C (-31 to +158°F) < 85% non condensing NC316BU-16T/DC - 40.5 - 57 5.0 -35 to +60°C (-31 to +140°F) -35 to +70°C (-31 to +158°F) < 85% non condensing * Compliant with ANSI TI.315-1994 standard Regulatory Compliance: FCC Part 15 (Class A); IC (Class A); EMC Directive: Emission (Class A) and Immunity; LVD Directive: Electrical Safety; CE Marking; TUV CUE Mark (Canada, USA, EU); GOST (selected products); RoHS Directive, WEEE Directive: Wheelie Bin Mark; ETSI, NEBS (selected products), C-Tick (selected products). Contact your sales representative for details. MRV has more than 50 offices throughout the world. Addresses, phone numbers, and fax numbers are listed at www.mrv.com. Please e-mail us at [email protected] or call us for assistance. MRV (West Coast USA) 20415 Nordhoff St. Chatsworth, CA 91311 800-338-5316 818-773-0900 MRV (East Coast USA) 295 Foster St. Littleton, MA 01460 800-338-5316 978-952-4700 MRV (International) Business Park Moerfelden Waldeckerstrasse 13 64546 Moerfelden-Walldorf Germany Tel. (49) 6105/2070 Fax. (49) 6105/207-100 All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information. MRV Communications and the MRV Communications logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders. MRV-FD-CHASS-120506 1398005-001 Rev. B Copyright ©2006 MRV Communications, Inc. All Rights Reserved.