NED-50 50W Dual Output Switching Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test 2 years warranty SPECIFICATION NED-50A MODEL CH1 CH2 CH1 CH2 DC VOLTAGE 5V 12V 5V 24V RATED CURRENT 6A 2A 4A 1.4A 0.3 ~ 3A 1 ~ 6A 0.2 ~ 2A CURRENT RANGE Note.6 1 ~ 6A 54W RATED POWER OUTPUT INPUT RIPPLE & NOISE (max.) Note.2 80mVp-p 6.0% 200mVp-p 6.0% 0.5% 1.0% 0.5% 1.0% LOAD REGULATION Note.5 1.5% 3.0% 1.5% 3.0% SETUP, RISE TIME 500ms, 30ms/230VAC HOLD UP TIME (Typ.) 50ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE EFFICIENCY(Typ.) 47 ~ 63Hz 79% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.1A/115VAC 0.65A/230VAC COLD START 45A 1200ms, 30ms/115VAC at full load 10ms/115VAC at full load 120 ~ 370VDC 82% LEAKAGE CURRENT <2mA / 240VAC OVERLOAD 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE CH1: 5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. -20 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CB(IEC60950-1) approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT EMS IMMUNITY Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, light industry level, criteria A DIMENSION PACKING NOTE CH1: 4.75 ~ 5.5V 2.0% Note.4 MTBF OTHERS 80mVp-p LINE REGULATION TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE (Note 7) 120mVp-p CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY EMC 53.6W VOLTAGE ADJ. RANGE PROTECTION SAFETY & NED-50B OUTPUT NUMBER 413.3K hrs min. MIL-HDBK-217F (25 129*98*38mm (L*W*H) 0.44Kg; 45pcs/21Kg/1.24CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can't exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:NED-50-SPEC 2010-10-18 NED-50 50W Dual Output Switching Power Supply Mechanical Specification Case No. 903 series Unit:mm 31 9.5 1 3.5 7 122.5 2 2- M 3 3 5 98 85.5 8.2 33 4 6 7 +V ADJ. 3.5 73.5 4.5 129 6.5 120 32 3 38 3.5 28.5 3-M 18 18.5 Assignment DC OUTPUT +V2 DC OUTPUT COM DC OUTPUT +V1 9 Pin No. 5 6 7 3.5 Assignment Pin No. 1 AC/L 2 AC/N 3 FG 4 DC OUTPUT COM 9.5 Terminal Pin No. Assignment 77 Block Diagram fosc : 60KHz RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER +V2 RECTIFIERS & FILTER +V1 COM DETECTION CIRCUIT FG O.L.P. CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 85 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:NED-50-SPEC 2010-10-18