250 MS/s, 125 MHz, 8-Bit Digitizers NI 5114 NEW! • • • • • • • 250 MS/s real-time sampling 5 GS/s random-interleaved sampling 8-bit resolution 125 MHz bandwidth 40 mVpp to 40 Vpp input range 8, 64, or 256 MB memory per channel Edge, window, hysteresis, video, and digital triggering with 40 ps timestamping Calibration • Gain, offset, compensated 1 MΩ attenuator, and timing self-calibration • 2-year external calibration interval Operating Systems • Windows Vista/XP/2000 • LabVIEW Real-Time Recommended Software • • • • LabVIEW LabWindows™/CVI Measurement Studio for Visual Studio LabVIEW SignalExpress Driver Software (included) • NI-SCOPE Soft Front Panel and driver • LabVIEW Express VIs >> For complete specifications, see the NI 5114 Specifications manual at ni.com/manuals. Overview Applications Aerospace/Defense RADAR, SONAR, and LIDAR Satellite Signal intelligence Biomedical and Scientific Research Ultrasonic medical imaging Mass spectrometry Particle physics Communications xDSL Wireless communications Baseband I & Q National Instruments PXI-5114 and PCI-5114 high-speed digitizers feature two 250 MS/s simultaneously sampled input channels with 8-bit resolution, 125 MHz bandwidth, and up to 256 MB of memory per channel in a compact, 3U PXI or PCI device. With the National Instruments Synchronization and Memory Core (SMC) architecture of an NI 5114, you can create mixed-signal systems using signal generators and digital waveform generator/analyzers or build a high-channel-count digitizer with subnanosecond synchronization between channels. An NI 5114 is ideal for a wide range of application areas including communications, scientific applications, military/aerospace, and consumer electronics. Dual 250 MS/s, 8-Bit Input Channels • 125 MHz input bandwidth with noise filters • 5 GS/s equivalent-time sampling (ETS) for repetitive signals • Independent channel-selectable 40 mVpp to 40 Vpp input ranges • Independent channel-selectable 50 Ω or 1 MΩ input impedance • 2-year calibration interval and 0 to 55 °C operating temperature Deep Onboard Memory • 8, 64, or 256 MB of memory per channel • Capture more than 1 million triggered waveforms in multiple record mode with hardware trigger rearming • Stream data continuously from onboard memory to host memory or disk Triggering, Clocking, and Synchronization • Edge, window, hysteresis, and digital triggering with 40 ps timestamping • Pretrigger and posttrigger acquisition in single- and multiple-record mode • Internal 250 MHz clock or external clock from 50 to 250 MHz • Phase lock to PXI 10 MHz reference or external reference from 1 to 20 MHz • Timestamp-triggered events with 100 ps resolution Software • IVI-compliant NI-SCOPE driver for NI LabVIEW and LabWindows/CVI as well as Microsoft C++ and Visual Basic with more than 50 built-in measurements • NI-SCOPE Soft Front Panel for interactive control Ordering Information NI PXI-5114 ........................................................................779466-0M1 NI PCI-5114 ........................................................................779745-0M1 1M (memory per channel): 1 (8 MB), 2 (64 MB), 3 (256 MB) Includes NI-SCOPE Soft Front Panel and driver. Recommended PXI Switch NI PXI-2593 (500 MHz mux/matrix) ......................................778793-01 BUY NOW! For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/digitizers. 250 MS/s, 125 MHz, 8-Bit Digitizers Spectral Characteristics (typical) Specifications Dynamic performance (10 MHz, -1 dBFS input signal) These specifications are valid for 0 to 55 °C, unless otherwise stated. Acquisition System Number of channels............................ 2 simultaneously sampled Vertical resolution............................... 8 bits Bandwidth (-3 dB) Range (Vpp) All except 0.04 0.04 Minimum Bandwidth 125 MHz 100 MHz Bandwidth limit filters (software-selectable) ......................... 20 MHz noise filter Maximum sampling rate..................... 250 MS/s real-time sampling, 5 GS/s equivalent-time/ random-interleaved sampling Onboard sample memory.................... 8, 64, or 256 MB per channel (8, 64, or 256 million samples) Multiple Record Acquisition (0 to 100% pretrigger and posttrigger data) Memory/Channel Maximum Number of Records 8 MB 32,768 64 MB 100,0001 256 MB 100,0001 1Infinite in streaming configuration. Input impedance ................................. 50 Ω and 1 MΩ || 26 pF, software-selectable Full-Scale Input Range and Programmable Vertical Offset 50 Ω 1 MΩ Range Vertical Offset Range Vertical Offset (Vpp) Range (V) (Vpp) Range (V) 0.04 0.1 0.2 0.4 1.0 2.0 4.0 10 – – ±0.8 ±0.8 ±0.8 ±0.8 ±6.5 ±6.0 ±5.0 ±2.0 – – 0.04 0.1 0.2 0.4 1.0 2.0 4.0 10 20 40 ±0.8 ±0.8 ±0.8 ±0.8 ±8.0 ±8.0 ±8.0 ±30 ±25 ±15 Maximum input overload.................... 50 Ω: 7 Vrms with | peaks | ≤10 V; 1 MΩ: | peaks | ≤35 V Input coupling ..................................... AC, DC, GND – AC coupling available on 1 MΩ only AC coupling cutoff frequency (-3 dB).. 12 Hz (1 MΩ) Accuracy DC accuracy (0 V offset setting) ......... ±(1.5% of input +0.3% of FS + 200 µV) for PXI-5114 ±(1.5% of input +0.3% of FS + 280 µV) for PCI-5114 Channel-to-channel crosstalk ............. -60 dB at 10 MHz SFDR THD ENOB SINAD Range (Vpp) All Ranges Except 0.04 58 dBc -58 dBc 7.2 44 dB 0.04 58 dBc -58 dBc 6.2 38 dB RMS Noise 20 MHz filter enabled ......................... 0.28% of FS Timebase System Timebase options................................ Internal, external (CLK IN) Internal Internal sample clock frequency ........ 250 MS/s sampling rate with decimation by n, 1 ≤ n ≤ 65,535 Timebase accuracy.............................. ±25 ppm (±0.0025%) External External clock sources ........................ CLK IN (SMB connector) External clock range............................ 50 to 250 MHz with decimation by n where 1 ≤ n ≤ 65,535 External reference sources ................. CLK IN (SMB connector), PXI_CLK10 (PXI backplane 10 MHz) External reference range .................... 1 to 20 MHz in 1 MHz increments External clock/reference amplitude.... Sine wave: 0.65 to 2.8 Vpp (0 to 13 dBm) Square wave: 0.2 to 2.8 Vpp External clock/reference impedance .. 50 Ω, AC coupled Trigger System Modes ................................................. Edge, hysteresis, window, video, digital, immediate, software Sources................................................ CH 0, CH 1, TRIG, PXI_Trig <0..6>, PXI star, software Slope ................................................... Rising or falling Hysteresis............................................ Fully programmable High-frequency reject filter................. 50 kHz software-selectable Low-frequency reject filter ................. 50 kHz software-selectable Sensitivity CH 0 and CH 1 ................................ 5% FS TRIG ................................................ 0.5 Vpp Level accuracy CH 0, CH 1 ...................................... ±5% FS up to 10 MHz TRIG ................................................ ±0.5 V up to 10 MHz Time resolution ................................... 40 ps with time-to-digital converter enabled Rearm time1 ........................................ 2 µs Holdoff1 ............................................... From 2 µs to [(235-1) x (sample clock period)], software-selectable 1Time-to-digital converter disabled. BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) 2 250 MS/s, 125 MHz, 8-Bit Digitizers External Trigger Channel (TRIG) Safety and Compliance Impedance........................................... 1 MΩ || 22 pF Vertical range...................................... ±5 V Coupling .............................................. AC, DC Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: Intermodule SMC Synchronization Using NI-TClk (typical) Skew.................................................... 500 ps ≤20 ps after manual adjustment Power Requirements (typical) PXI PCI +3.3 VDC 840 mA 1.6 A +5 VDC 1.1 A 1.7 A +12 VDC 250 mA 45 mA -12 VDC 170 mA 0A Total Power 13.32 W 14.32 W Environment Operating temperature2 ...................... 0 to 55 °C for PXI-5114, 0 to 45 °C for PCI-5114 (meets IEC-60068-2-1 and IEC-60068-2-2) Storage temperature........................... -40 to 71 °C (meets IEC-60068-2-1 and IEC-60068-2-2) Relative humidity ................................ 10 to 90%, noncondensing (meets IEC-60068-2-56) 20 to 45 °C in PXI-101x or PXI-1000/B chassis. Calibration Self-calibration.................................... Gain, offset, compensated 1 MΩ attenuator, triggering, and timing for all input ranges External calibration interval................ 2 years • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note: For UL and other safety certifications, refer to the product label or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Electromagnetic Compatibility This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use: • EN 61326 EMC requirements; Minimum Immunity • EN 55011 Emissions; Group 1, Class A • CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A Note: For EMC compliance, operate this device according to product documentation. CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: • 2006/95/EC; Low-Voltage Directive (safety) • 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Note: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Waste Electrical and Electronic Equipment (WEEE) EU Customers: At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee.htm. BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) 3 NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Professional Services Our NI Professional Services team is composed of NI applications and systems engineers and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. ni.com • 800 813 3693 Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. *351544A-01* 351544A-01 2007-9252-101-D © 2007 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, SCXI, and SignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments.