EMERSON-NETWORKPOWER NLP65_09

Embedded Power for
Business-Critical Continuity
Rev.11.2.09_104
NLP65 Medical
1 of 4
NLP65 Medical
Series
Single, Dual and Triple output
Total Power:
Input Voltage:
# of Outputs:
65 W
85 - 264 VAC
Single, Dual, Triple
Special Features
• 85 VAC to 264 VAC universal
input range
• Harmonic current correction
as standard
• Maximum component height
1.26 inches
• UL, CSA and VDE safety approvals
• Overvoltage and short circuit
protection
• 5 x 3 x 1.26 inch (127.0 x 76.2 x
32mm) footprint
• Available RoHS compliant
• 2 year warranty
Electrical Specifications
Input
Input voltage range:
Universal input
(see Note 2)
Input frequency range:
85 - 264 Vac
47 - 63 Hz
Input current:
(cold start)
120 Vac
230 Vac
17 A max.
32 A max
Safety ground leakage current:
264 Vac, 60 Hz
95 µA
Input current:
120 Vac
230 Vac
1.05 A rms
0.51 A rms
Input fuse:
250 Vac F 3.15 A
Output
Output power:
Total regulation:
(line and load)
Rise time:
Safety
Transient response:
•VDE0705/EN60601-1/IEC1010
File No. 10401-3336-0156/32480
Licence No. 121949
•UL1950 File No. E147937
•CSA C22.2 No. 950
File No. LR41062C
•CE Mark: LVD
Temperature coefficient:
Natural convection
65 W max.
See table
At turn-on
1.0 s, max
Main output
25% step at 0.1 A/µs
5.0% max. dev.,
1ms recovery to 1.0%
± 0.02%/°C
Overvoltage protection:
Main outputs
125%, ± 10%
Short circuit protection:
Cyclic operation
Yes
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.
Rev.11.2.09_104
NLP65 Medical
2 of 4
EMC Charateristics
Conducted emissions:
EN55022, FCC part 15
Level A
Radiated emissions:
EN55022, FCC part 15
Level A
ESD air:
EN61000-4-2, level 3
Perf. criteria 1
ESD contact:
EN61000-4-2, level 4
Perf. criteria 1
Surge:
EN61000-4-2, level 3
Perf. criteria 1
Fast transients:
EN61000-4-4, level 3
Perf. criteria 1
Radiated immunity:
EN61000-4-3, level 3
Perf. criteria 2
Conducted immunity:
EN61000-4-6, level 3
Perf. criteria 2
Hold-up time:
120 Vac, 60 Hz
16 ms @ 65 W
Efficiency:
120 Vac, 65 W
72% typical
Isolation voltage:
Input/output
Input/chassis
4000 Vac
1500 Vac
Switching frequency:
Fixed
100 kHz, ± 5 kHz
Approvals and standards:
EN60601, UL2601, CSA 22.2 No. 125
Weight:
283 g (10 oz)
MTBF demonstrated:
MIL-HDBK-217F
General Specifications
150,000 hours
Environmental Specifications
Thermal performance:
Operating ambient
(See derating curve)
0° C to +70 °C
Non-operating
-40 °C to +85 °C
75W
0 °C to 50 °C, ambient,
convection cooled
50 °C - 70 °C ambient,
convection cooled
65 W
65W
Peak (0 °C to 50 °C, 60 s)
See table
Relative humidity:
Non-condensing
5 to 95% RH
Altitude:
Operating
10,000 feet max.
DERATING CURVE
Output Power (Watts)
20 CFM FORCED AIR COOLING
Derate to 50% load
Non-operating
30,000 feet max.
Vibration (See Note 5):
5 - 500 Hz
2.4 G rms approx.
Shock
per MIL-STD-810E
516.4 Part IV
NATURAL
CONVECTION
COOLING
0°C
38W
32W
10°C 20°C 30°C 40°C 50°C 60°C 70°C
Embedded Power for
Business-Critical Continuity
Rev.11.2.09_104
NLP65 Medical
3 of 4
Ordering Information
Output
Voltage
Output Current
Ripple (4)
Total
Regulation (6)
Model Number (11, 12)
8A
50 mV
±2.0%
NLP65-9908J
Max (1)
Peak
Fan (10)
+5 V
7A
9.1 A
+12 V
2.5 A
3.3 A
3A
150 mV
±5.0%
–12 V
0.5 A
0.81 A
1A
120 mV
±5.0%
+5 V
7A
9.1 A
8A
50 mV
±2.0%
+24 V
2A
2.6 A
2A
240 mV
±5.0%
NLP65-9920J
+5 V
7A
9.1 A
8A
50 mV
±2.0%
+12 V
2.5 A
3.3 A
3A
150 mV
±5.0%
NLP65-9929J
+12 V
5.4 A
7A
6.5 A
120 mV
±2.0%
NLP65-9912J
+15 V
4.4 A
5.7 A
5.3 A
150 mV
±2.0%
NLP65-9915J
+24 V
2.7 A
3.5 A
3.5 A
240 mV
±2.0%
NLP65-9924J
Notes
1 Natural convection cooling. Models NLP65-9929J, and NLP65-9908Jmust not exceed 62.5 Watts continuous output power with natural convection. Model
NLP65-9920J not to exceed 65 Watts continuous output power with natural convection.
2 When the input voltage is less than 90 Vac the operating temperature range is 0 °C to +40 °C. The ripple and regulation specifications may not be met.
3 Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation limits.
4 Figure is peak-to-peak for convection power rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated
with a 10 µF electrolytic capacitor and a 0.1 µF ceramic capacitor.
5 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz.
6 To maintain stated regulation then:
for single output units
I ≥ 0.2 A I max.
for multiple output units
0.25 ≤ I(A)/I(B) ≤ 5, for I(A) ≥ 0.2 A I(A) max.
7 For optimum reliability, no part of the heatsink should exceed 120 oC, and no semiconductor case temperature should exceed 130 oC.
8 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements.
9 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product.
10 Maximum continuous output power for all multiple output models must not exceed 75 Watts with 20 CFM forced air cooling at 50 oC.
11 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
12 NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search
tool at http://www.PowerConversion.com to find a suitable alternative.
Embedded Power for
Business-Critical Continuity
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone:+1 760 930 4600
Facsimile: +1 760 930 0698
5.00
(127.00)
4.550
(115.57)
0.225
(5.715)
J1
1
1 L
3.00
(76.20)
6
T1
J2
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone:+44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
J3
3 N
Rev.11.2.09_104
NLP65 Medical
4 of 4
2.550
(64.770)
C19
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone:+852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
Mounting
Hole Diameter
0.156 (4.00)
ALL DIMENSIONS IN INCHES (mm)
Pin Connections
Input and Output
Connectors
Mating Connectors
AC (J1)
Molex 26-60-4030 type
Molex 09-50-3031 or equivalent with Molex
08-50-0105 or equivalent crimp terminals
DC (J3)
Molex 26-60-4060
Molex 09-50-3061 with Molex 2478 phosphor
bronze crimp terminals or equivalent.
J1
Pin 1
AC Line
Pin 2
No Pin
Pin 3
AC Neutral
Pin 1
MAXIMUM COMPONENT
HEIGHT 1.26 (32.00)
TOLERANCE: .xxx
0.005"
.xx
0.02"
www.PowerConversion.com
techsupport.embeddedpower@
emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
J2
Connectivity
Safety Ground
DC Power
Embedded Computing
Embedded Power
Output Pin Connections
J3
SINGLE
DUAL
TRIPLE
Pin 1
No Connection
V (B)
V (B)
Pin 2
V (A)
V (A)
V (A)
Pin 3
V (A)
V (A)
V (A)
Pin 4
Return
Return
Return
Pin 5
Return
Return
Return
Pin 6
No Connection
No Pin
V (C)
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and service marks of Emerson Electric Co.
©2009 Emerson Electric Co.