EMERSON-NETWORKPOWER NLP250MEDICAL_09

Embedded Power for
Business-Critical Continuity
Rev.05.12.09_181
NLP250 Medical Series
of 4
NLP250 Medical
Series
Single Output
Total Power: 250 W
Input Voltage: 85 - 264 VAC
# of Outputs: Single
Special Features
• Medical safeties
• Active PFC and
EN61000-3-2 compliant
• 250 W on main channel with
forced air
• Low profile fits 1U applications
• U-Channel for maximum
thermal performance
• Optional cover (CJ suffix)
• 5 V standby output
• 12 V fan output
• Integrated control and
monitoring features
• Overcurrent, overvoltage and
overtemperature protection
• Compliance to EN55022-B
conducted noise standard
• Dual AC fuses
• RoHS compliant
• 2 year warranty
Electrical Specifications
Input
Input voltage range:
Universal input
Input frequency range:
85 - 264 Vac
47 - 63 Hz
Input surge current:
264 Vac (cold start)
40 A max.
Safety ground leakage current:
Input current:
264 Vac, 50 Hz
120 Vac @ 250 W
230 Vac @ 250 W
Input fuse:
UL/IEC127
150 µA
2.78 A rms
1.36 A rms
T6.4 AH, 250 Vac In live and
neutral
Output
Maximum power:
Adjustment range:
Total regulation:
(line and load)
Turn-on delay:
Transient response:
200 LFM forced air
250 LFM with cover
Main output
250 watts
Main output
Auxiliary outputs
@ 120 Vac Input
Main output
50 - 100%
Step at 0.5 A/µs
± 2.0%
± 5%
± 5.0%
2.0 s max.
5.0% or 250 mV
max. dev., 1 ms max
recovery to 1%
Safety
Temperature coefficient:
•
•
•
•
Overvoltage protection:
Main output
115%, ± 5%
Short circuit protection:
Cyclic operation
Continuous
Minimum output current:
Auxiliary outputs:
(See Note 8, page 3)
Singles
5 Vsb
12 V (fan)
0A
5 V @ 1.0 A
12 V @ 0.3A
VDE0750/EN60950
IEC950/IEC60601-1
File No. 1177400-3336-0759
UL60601-1
File No. E186249
Certificate No. 40014041
CB Ref DE1-36628
±0.02%/°C
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
Embedded Power for
Business-Critical Continuity
Rev.05.12.09_181
NLP250 Medical Series
of 4
EMC Characteristics (5)
Conducted emissions:
EN55022, FCC part 15
Level B
Harmonic current correction:
EN61000-3-2
Compliant
Voltage flicker:
EN61000-3-3
Compliant
ESD air:
EN61000-4-2
Level 3
ESD contact:
EN61000-4-2
Level 3
Radiated immunity:
EN61000-4-3
Level 3
Fast transients:
EN61000-4-4
Level 3
Surge:
EN61000-4-5
Level 3
Conducted immunity:
EN61000-4-6
Level 3
Voltage dips:
EN61000-4-11
Compliant
Hold-up time:
85 Vac @ 50 Hz
20 ms @ 250 W
Efficiency:
115 Vac @ 250 W
230 Vac @ 250 W
84% typ.
86% typ.
Isolation voltage:
Input/output
Input/chassis
4000 Vac
2000 Vac
Safety approvals (see Note 6, page 3):
UL/cUL UL60601-1, VDE EN60601-1, CAN/CSA22.2 No. 601-1
General Specifications
Weight:
MTBF (@25º C):
650g (22 oz)
Telcordia SR-332
MIL-HDBK-217F
317,000 hours min.
158,000 hours min.
Environmental Specifications
Thermal performance:
Operating ambient,
0 °C to +70 °C
(See derating curve)
Non-operating
-40 °C to +85 °C
0 °C to 50 °C ambient,
250 W
200 LFM forced air
250 LFM with cover
0 °C to 50 °C ambient,
175 W
0 °C to 40 °C with cover
Convection cooled
50 °C to 70 °C ambient,
Derate linearly
Convection cooled
to 50% load
Relative humidity:
Non-condensing
5 - 95% RH
Altitude:
Operating
10,000 feet max.
Non-operating
30,000 feet max.
Vibration (See Note 7, page 3):
5 - 500 Hz
2.5 G rms peak
Shock:
Per MIL-STD-810E
516.4 Part IV
Embedded Power for
Business-Critical Continuity
Rev.05.12.09_181
NLP250 Medical Series
of 4
Ordering Information
Output Voltage
12 V
24 V
Output Current
Min
0A
0A
Max (free air) (1,4) Max (forced air) (2,4)
14.6 A
7.3 A
21 A
10.5 A
Notes
1 Free air convection. Maximum continuous output power not to exceed 175 W. Refer to Figure 1 for the derating curve.
2 200 LFM (250 LFM with cover) forced air cooling from the longer side.
Maximum continuous output power not to exceed 250 W.
3 Figure is peak-to-peak for room temperature rating. Output noise
measurements are made across a 20 MHz bandwidth using a 6 inch twisted
pair, terminated with a 10 µF tantalum capacitor and a 0.1 µF ceramic
capacitor.
4 CAUTION: Allow a minimum of 1 second after disconnecting line power when
making thermal measurements. For optimum reliability no part of the heatsink
should exceed 115 °C and no semi-conductor case temperature should exceed
120 °C.
Ripple (3)
Total Regulation
Model Numbers (9, 10)
120 mV
240 mV
± 2.0%
± 2.0%
NLP250N-99S12J
NLP250N-99S24J
5 No external filtering required during conducted emissions testing but some
applications may require additional filtering to achieve system compliance. Compliance with radiated EMI specifications may require mounting in a
suitable enclosure.
6 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
7 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G
8 5 V sb (standby) output is available whenever AC is present, regardless of
remote ON/OFF signal status. 12 V (fan) present when main output is present.
9 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
“CJ” suffix indicates covered RoHS version.
10 NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
search tool at http://www.PowerConversion.com to find a suitable alternative.
Mechanical Drawing
CUSTOMER MOUNTING HOLES
MAX. SCREW PENETRATION 0.08IN
6-32
JP1
VR7
J4
J2
1
5.850 (148.59)
1
0.25 (6.35)
7.000 [177.80]
M3.0
6.250 (158.75)
M3.0
4 PLACES
6-32
4 PLACES
4.700 (119.38)
1.500 [38.10]
5.500 (139.70)
BOTTOM VIEW
2.500 (63.50)
J3
0.750 (19.05)
1.140
(28.96)
1
E
L
N
4.000 [101.60]
J1
Embedded Power for
Business-Critical Continuity
Figure 1b: Derating Curve With Cover
Output Power (Watts)
Figure 1: Derating Curve
Output Power (Watts)
DERATING CURVE Output Power (Watts)
DERATING CURVE Output Power (Watts)
WITH COVER
All Models
Forced Air
250 W
250 W
24 V Free Air
200 LFM (1.0 m/s)
FORCED AIR COOLING
24 V Free Air
250 LFM (1.25 m/s)
FORCED AIR COOLING
12 V Free Air
175 W
All Models
Forced Air
12 V Free Air
175 W
125 W
125 W
87 W
75 W
NATURAL FREE AIR
CONVECTION COOLING
NATURAL FREE AIR
CONVECTION COOLING
0W
0C
75 W
0W
10 C
20 C
30 C
40 C
50 C
60 C
70 C
0C
10 C
20 C
30 C
40 C
50 C
60 C
70 C
Type
Mating Connector Type
J1
Molex 09-65-2058 (5273 series)void pins Molex 09-52-4054 (5239 series) or equivalent with Molex
2 and 4 or equivalent
08-52-0072 (2478 series) or equivalent crimp terminals
J2
Molex 22-23-2021 (6373 series) or
equivalent
Molex 22-01-3027 (2695 series) or equivalent with Molex
08-50-01113 (2759 series) or equivalent crimp terminals
J3
Molex terminal block 387007504 or
equivalent
Terminal block contains #6-32 screw with clamp
washer suitable for wire size 12-22 awg (0.5-2.5 mm2).
Max Torque tp 1.36 Nm (12 in.lb)
J4
Molex 22-23-2091 (6373 series) or
equivalent
Molex 22-01-3097 (2695 series) or equivalent with Molex
08-50-0113 (2759 series) or equivalent crimp terminals
Pin Connections
J1
Pin Connections Continued
J2
Pin 1
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone:+1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone:+44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
Connector and Mating Connector Types
Connector
­Americas
Rev.05.12.09_181
NLP250 Medical Series
of 4
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone:+852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.PowerConversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
Ground/Earth
Pin 1
+12 V
Fan Voltage
Pin 2
Live
Pin 2
SGND
Return
Pin 3
Neutral
Vo
+ Main Output
Connectivity
Pin 2
Vo
+ Main Output
DC Power
Pin 3
RTN
Main Return
Embedded Computing
Pin 4
RTN
Main Return
Embedded Power
+S
+Vo Remote Sense
Outside Plant
J3
Pin 1
AC Power
J4
Pin 1
Monitoring
Pin 2
-S
Vo Remote Sense
Power Switching & Controls
Pin 3
LS
Load Share Signal
Pin 4
PS OFF
Remote ON/OFF signal NO
Precision Cooling
Racks & Integrated Cabinets
Pin 5
PS ON
Remote ON/OFF signal NC
Services
Pin 6
SGND
Signal Common
Pin 7
PW OK
Power Good
Pin 8
5 Vsb
Stand-by Voltage
Pin 9
DC OK
DC Power Good Signal
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co. ©2009 Emerson Electric Co.