POWERDYNAMICS PBH16W-60-1CU

POWER LINE FILTER
PBH Series
16/20A HIGH CURRENT, SNAP-IN/FLANGE MOUNT FILTER
WITH IEC 60320 AC INLET SOCKET.
MECHANICAL DIMENSIONS (Unit: mm)
CASE F
42.0
35.0
52.8
42.0
30.1
R3 TYP.
27.0
2x 3.5
3.6
(79.5)
67.4
6.35
✛
0.8
34.0
26
CASE U
FEATURES
The PBH series offers filters for application that have high
current (16/20A) requirements. The filters are available
with different configurations of components and termination
styles. These filters are available in flange mount and
snap-in type. The medical grade filters offer excellent
performance with maximum leakage current of 2µA at
120VAC, 60Hz.
A ground choke can be added to enhance the grounding
ability of the circuit. A bleeder resistor can also be added
to prevent excessive voltages from developing across the
filter capacitors when there is no load.
30.0
✛ SEMKO, VDE approved to 16A
* Medical application
R3 TYP.
27.6
3.8
(79.5)
67.4
6.35
0.8
34.0
26.0
CASE O
2x
43.0+-- 0.1
34.5+ 0.5
6#32
10.0+-- 0.1
TECHNICAL DATA
• Rated Voltage: 115/250VAC
• Rated Current: 16A, 20A
• Power Line Frequency: 50/60Hz
• Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.50mA
@ 115VAC 60Hz: 2µA*
@ 250VAC 50Hz: 5µA*
• Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
• Temperature Range: -25C to +85C
27.0
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
36.0
38.0
+ 0.5
6.0 +-- 0.1 26.5--
30.0
43.0
52.0
79.5
R3.0
2x 3.5
RECOMMENDED
PANEL CUTOUT
(MOUNTING FROM REAR)
75.7
0.8
6.35
34
26
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
13
PBH Series Example & Ordering Code
PBH 20 Q - 60 - 1
C
U
SCHEMATICS
1
LINE
CURRENT RATING (A):
= 16
= 20
R
Cy
CX
L
Cy
N
L'
G'
LOAD
L mH
L
N'
L mH
G
Lg
TERMINAL:
3.0 -3.6L
4.0/0.187
6.6
UL 1015, 18AWG
STRANDED, 4”
QUICK CONNECT
=Q
SOLDER
=S
WIRE
=W
2
L mH
L
Cy
R
L
Cy
N
L'
G'
LOAD
2.0 -3.0L
LINE
8.0
6.3/0.25
N'
L mH
G
Lg
GROUND CHOKE (100µH)
COMPONENT LOCATIONS:
00
60
80
90
3
STANDARD TYPE
WITHOUT C(X); C(Y) ONLY
C(X) & C(Y) BEHIND L
WITHOUT C(Y); C(X) ONLY
WITHOUT C(Y); C(X) BEHIND L
=
=
=
=
=
1
2✢
3✢
1M
2M✢
Cy
20A (mH)
0.5
0.5
0.5
1M
=A
=B
=C
L mH
L
R
CX
N'
L mH
G
= M1
= M2
2M
L mH
FLANGE MOUNT
SNAP-IN TABS - SIDE
REAR PANEL MOUNT
= F
=U
=O
LINE
L
Comm. Mode(L-G)
.15 .5 1
5
17 22 26 43
17 23 28 47
17 22 26 43
in MHz
10 30
51 43
57 45
51 43
Diff. Mode(L-L)
.15 .5 1 5
8 18 24 45
8 18 23 51
18 28 33 46
14
N'
L mH
G'
✧
Insertion loss in dB (50 Ohm circuit)
in MHz
10 30
43 35
54 34
53 35
This table applies to schematic 1 only.
Visit our website or contact PDI for other schematic attenuation numbers.
❖
L'
CX
Lg
Medical Applications
Insertion loss in dB (50 Ohm circuit)
Attenuation
Code
A
B
C
L
G
Contact PDI for attenuation numbers
❖
R
N
✢
Non-Medical Applications
G'
Lg
16/20A (mH)
0.5
0.5
CASE CODE:
L'
L
N
Cap. Cx (µF)
0.1
0.33
N'
L mH
MEDICAL
SCHEMATICS
Medical applications, select Attenuation code with corresponding component values from the table.
Case Code
F,O,U
F,O,U
L'
G'
Lg
LINE
Cap. Cy (pF)
2200
3300
2200
Cy
CX
L
G
Non-Medical applications, select Attenuation code with corresponding component values from the table.
Cap. Cx (µF)
0.1
0.1
0.33
R
N
ATTENUATION CODE TABLE:
Case Code
F,O,U
F,O,U
F,O,U
L mH
L
LOAD
BLEEDER RESISTOR (1W, 1M) & GROUND CHOKE
=
=
=
=
LOAD
BLEEDER RESISTOR (1W, 1M)
LOAD
NO BLEEDER RESISTOR & NO GROUND CHOKE
LINE
OPTIONS:
Attenuation
Code
M1
M2
Comm. Mode(L-G)
.15 .5 1
5
16 21 22 24
16 20 22 24
in MHz
10 30
25 20
25 20
Diff. Mode(L-L)
.15 .5 1 5
8 18 25 42
17 28 33 41
in MHz
10 30
43 30
40 31
✧
This table applies to schematic 1M only.
Visit our website or contact PDI for other schematic attenuation numbers.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com