PLC-100 100W Single Output Switching Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage / Over temperature Built-in active PFC function UL1310 Class 2 power unit Cooling by free air convection 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting 2 years warranty 110 F M M MODEL PLC-100-20 PLC-100-24 PLC-100-27 PLC-100-36 PLC-100-48 15V 20V 24V 27V 36V 48V 10.5 ~ 15V 14 ~ 20V 16.8 ~ 24V 18.9 ~ 27V 25.2 ~ 36V 33.6 ~ 48V Note.6 5A 5A 4.8A 4A 3.55A 2.65A 2A CURRENT RANGE Note.6 0 ~ 5A 0 ~ 5A 0 ~ 4.8A 0 ~ 4A 0 ~ 3.55A 0 ~ 2.65A 0 ~ 2A RATED POWER Note.6 60W 75W 96W 96W 95.85W 95.4W 96W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p VOLTAGE ADJ. RANGE(ADJ V) 10.2 ~ 12V 12.8 ~ 15V 17 ~ 20V 20.4 ~ 24V 23 ~ 27V 30.6 ~ 36V 40.8 ~ 48V CURRENT ADJ. RANGE(ADJ I) 3.75 ~ 5A 3.75 ~ 5A 3.6 ~ 4.8A 3 ~ 4A 2.6 ~ 3.55A 2 ~ 2.65A 1.5 ~ 2A 3.0% 3.0% 2.0% 2.0% VOLTAGE TOLERANCE Note.3 3.0% LINE REGULATION 1.0% 60ms/230VAC 30ms/115VAC at full load HOLD UP TIME (Typ.) Note.5 90 ~ 264VAC 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 85% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 12V:0.8A/115VAC 0.4A/230VAC COLD START 40A/230VAC OVER CURRENT (Typ.) Note.4 PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS Note.7 WITHSTAND VOLTAGE PF>0.95/115VAC at full load 86% 89% PF 0.9 at 70 ~ 100% load 88.5% 15V:0.9A/115VAC 88% 0.45A/230VAC 88% 20V ~ 48V:1.1A/115VAC 89% 0.55A/230VAC <0.75mA / 240VAC 95 ~ 102% Protection type : Constant current limiting, recovers automatically after fault condition is removed 13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 30 ~ 36V 39 ~ 48V 52 ~ 64V Protection type : Shut down and latch off o/p voltage, re-power on to recover 90 10 (RTH2) Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +50 (Refer to output load derating curve) 20 ~ 95% RH non-condensing -40 ~ +80 0.03%/ , 10 ~ 95% RH (0 ~ 50 ) 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes UL1310 Class 2, EN61347-1, EN61347-2-13 independent,UL60950-1, TUV EN60950-1, UL879 ( listed in UL Sign Components Manual (SAM) ) CAN/CSA C22.2 No. 223-M91(except for 48V) approved I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3, Class C ( 70% load) ; EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level, (surge 4KV), criteria A EMS IMMUNITY MTBF 297.9Khrs min. MIL-HDBK-217F (25 ) DIMENSION PACKING NOTE 127 ~ 370VDC FREQUENCY RANGE LEAKAGE CURRENT OTHERS 3.0% 1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load SETUP, RISE TIME VOLTAGE RANGE 3.0% 2.0% LOAD REGULATION EMC ( except for 48V ) PLC-100-15 RATED CURRENT SAFETY & ( for 48V only) 12V CONSTANT CURRENT REGION Note.4 8.4 ~ 12V INPUT LPS PLC-100-12 DC VOLTAGE OUTPUT SELV EQUIVALENT SPECIFICATION 200.5*70.5*35mm (L*W*H) 0.52Kg; 25pcs/14Kg/0.65CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 5. Derating may be needed under low input voltage. Please check the derating curve for more details. 6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18. File Name:PLC-100-SPEC 2009-01-12 PLC-100 100W Single Output Switching Power Supply Mechanical Specification Case No.981A series Unit:mm 200.5 70.5 20.63 6.26 20.93 2-R2.5 35 6.26 Fosc : 100KHz Block Diagram EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V O.L.P. FG O.L.P. PFC CONTROL DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. Derating Curve Static Characteristics Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -10 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:PLC-100-SPEC 2009-01-12