L P V- 3 5 35W Single Output Switching Power Supply series Features : Constant voltage design Universal AC input / Full range Epoxy encapsulated with IP67 level Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage Fully isolated plastic case Cooling by free air convection UL1310 Class 2 power unit, pass LPS 100% full load burn-in test Low cost, high reliability Suitable for LED lighting and moving sign applications MODEL OUTPUT LPV-35-5 LPV-35-12 LPV-35-15 LPV-35-24 DC VOLTAGE 5V 12V 15V 24V 36V RATED CURRENT 5A 3A 2.4A 1.5A 1A CURRENT RANGE 0 ~ 6A (Note.7) 0 ~ 3A 0 ~ 2.4A 0 ~ 1.5A 0 ~ 1A RATED POWER 30W 36W 36W 36W 36W 120mVp-p 120mVp-p 150mVp-p 150mVp-p 85% 85% RIPPLE & NOISE (max.) Note.2 80mVp-p VOLTAGE TOLERANCE Note.3 6.0% LINE REGULATION 1.0% SETUP, RISE TIME 2.0% Note.6 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load HOLD UP TIME (Typ.) 50ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 77% AC CURRENT INRUSH CURRENT(max.) 1.1A/115VAC 0.7A/230VAC COLD STAR 30A/115VAC 60A/230VAC Note.4 PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION 16ms/115VAC at full load 84% 84% 0.25mA / 240VAC LEAKAGE CURRENT OVER CURRENT LPV-35-36 5.0% 4.0% LOAD REGULATION INPUT LPS IP67 2 years warranty SPECIFICATION 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 41.4 ~ 48.6V Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +75 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +80 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS Design refer to UL1310 Class 2,TUV EN60950-1, CAN/CSA C22.2 No. 223-M91, EN61347-2-13, IP67 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B OTHERS HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 743.5Khrs min. MIL-HDBK-217F (25 ) DIMENSION 148*40*30mm (L*W*H) 0.34Kg; 40pcs/14.6Kg/0.63CUFT PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the derating curve for more details. 5. The power supply is considered a component which will be installed a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. LPV-35-5 can provide 6A of output current continuously. Based on the requirement of UL1310 class 2, the output current is only certified up to 5A for the test report of LPV-35-5. File Name:LPV-35-SPEC 2008-10-21 L P V- 3 5 35W Single Output Switching Power Supply Mechanical Specification Case No.975A 148 600 series Unit:mm 600 18AWG 3.6 16AWG 40 3.6 3.5 AC/L(Brown) AC/N(Blue) 3.5 3.5 +V(Red) -V(Black) 30 3.5 Block Diagram fosc : 65KHz EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING O.L.P. +V -V DETECTION CIRCUIT PWM CONTROL O.V.P. Derating Curve Static Characteristics Ta=25 100 100 Others 90 80 80 5V 70 LOAD (%) LOAD (%) 60 40 20 -30 0 15 30 40 50 60 AMBIENT TEMPERATURE ( ) 70 75 80 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:LPV-35-SPEC 2008-10-21