120W Single Output Power Supply or Battery Charger PS-120 series Features : AC input range selected by switch Built-in passive PFC function compliance to EN61000-3-2 With AC ON-OFF switch 3 poles AC inlet with fuse holder Protections: Short circuit / Overload / Over voltage / Over temperature Charger type can be selected (Optional) Charger for lead-acid batteries 2 color LED loading indicator Open frame models available (Without safety approval) Low cost, High reliability 2 years warranty TUV Rheinland Product Safety S:Power Supply A:Voltage detector B:Current detector P A 120 P geprUfre Sicherheit 13 C :O.D.M. number P:Open P.C.B. C:With case 13:13.8V 27:27.6V 54:55.2V P:With PFC N:None PFC SPECIFICATION MODEL OUTPUT PS-120-13P/C PS-120-27P/C PS-120-54P/C DC VOLTAGE 13.8V 27.6V 54V RATED CURRENT 7.2A 4.3A 2.2A CURRENT RANGE 0 ~ 7.2A 0 ~ 4.3A 0 ~ 2.2A RATED POWER 99.36W 118.68W 118.8W RIPPLE & NOISE (max.) Note.2 150mVp-p 200mVp-p 250mVp-p VOLTAGE ADJ. RANGE 24 ~ 30V 1.0% 8.0% 48 ~ 60V 1.0% 7.5% VOLTAGE TOLERANCE Note.3 LINE REGULATION INPUT 12 ~ 15V 3.0% 8.5% 1.0% 1.0% 1.0% 5.0% LOAD REGULATION 1.0% 6.0% SETUP, RISE TIME 1000ms, 50ms at full load HOLD UP TIME (Typ.) 16ms at full load VOLTAGE RANGE 88 ~ 132VAC / 176 ~ 264VAC selected by switch FREQUENCY RANGE 47~63Hz POWER FACTOR (Typ.) >0.65 (with PFC series) EFFICIENCY (Typ.) 77%/70% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 3A/115VAC 1.5A/230VAC COLD START 25A/115VAC LEAKAGE CURRENT <1.5mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. 81%/76% 1.0% 1.0% 5.0% 82%/78% 50A/230VAC 15 ~ 17V 30 ~ 35V 60 ~ 66V Protection type : Hiccup mode, recovers automatically after fault condition is removed RTH2 70 10 detect on RTH2 thermistor Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.05%/ (0 ~ 45 VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 4) ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT EMS IMMUNITY OTHERS MTBF DIMENSION PACKING NOTE UL60950-1, TUV EN60950-1, EN60335, EN60335-1, EN60335-2-29 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 249.5K hrs min. MIL-HDBK-217F (25 ) PCB Type:144*90*33mm External case type:180*96*49mm (L*W*H) 1.1Kg; 16pcs / 17.9Kg / 1.47CUFT(without PFC) 1.24Kg; 16pcs / 20.1Kg / 1.47CUFT(with PFC) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. With PFC I/P range: 95~132VAC/190~264VAC. 6. For open P.C.B. WITH 17.8CFM min. Forced air. PS-120 120W Single Output Power Supply or Battery Charger Mechanical Specification Case No. PS-120A series Unit:mm 1 2 3 115 FUSE CASE: Output cable length=183cm 5cm Pin No. 1 2,3 Assignment DC OUTPUT +V DC OUTPUT -V Pin No. 1 2 3 Assignment AC/L No Pin AC/N 49 PCB: AC Input Connector (CN1) : JST B3P-VH or equivalent Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent 180 144 43. 134 5 8 12VDC FAN Output Connector (CN4) : JST B2B-XH or equivalent Assignment +V -V Mating Housing JST XHP or equivalent ADJ. Terminal CN4 JST SXH-001T-P0.6 or equivalent F4 A/250V Pin No. 1 2 CN3 +V JST SVH-21T-P1.1 or equivalent -V Terminal JST VHR or equivalent 1 2 3 4 Mating Housing 80 Assignment -V +V 90 Pin No. 1,2 3,4 5 DC Output Connector (CN3) : JST B4P-VH or equivalent LED 12 +CN5 1 2 3 SHORT FOR 115V OPEN FOR 230V CN1 Switch 115V 230V Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent 2 max. Assignment Short Open 33 115/230V selected by switch Connector (CN5) : JST B2P-VH or equivalent Derating Curve Static Characteristics (27V) 100 LOAD (%) 60 OUTPUT VOLTAGE (V) Open frame series 17.8CFM air cooling (L=15cm face HS) 80 Other series 40 20 -10 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 30 350 29 300 28 250 27 200 26 150 25 100 24 50 80 160 85 170 90 180 95 190 100 200 105 210 110 220 115 230 120 240 125 250 OUTPUT RIPPLE (mVp-p) Ta=25 130 260 INPUT VOLTAGE (VAC) 60Hz File Name:PA,PB-120-SPEC 2008-05-06