ECO-PACTM 3 Three Phase AC Controller Modules PSUT 65 PSUH 65 IRMS = 3 x 65 A VRRM= 800-1600 V W3C Preliminary Data Sheet VRSM VDSM (V) 900 1300 1500 1700 VRRM VDRM (V) 800 1200 1400 1600 Type W3H PSUT 65/08 PSUH 65/08 PSUT 65/12 PSUH 65/12 PSUT 65/14 PSUH 65/14 PSUT 65/16 PSUH 65/16 ECO-PACTM 3 Symbol I RMS ITRMS ITAVM ITSM Test Conditions 65 A TVJ = TVJM 47 A TC = 85 °C; 180° sine, per thyristor 30 A TVJ = 45 °C t = 10 ms (50 Hz), sine 550 A VR = 0 t = 8.3 ms (60 Hz), sine 600 A (50 Hz), sine 490 A VR = 0 t = 8.3 ms (60 Hz), sine 540 A TVJ = 45 °C t = 10 ms (50 Hz), sine 1500 A²s VR = 0 t = 8.3 ms (60 Hz), sine 1490 A²s (50 Hz), sine 1200 A²s t = 8.3 ms (60 Hz), sine 1210 A²s 150 A/µs TVJ = 125 °C t = 10 ms ∫ i2 dt TVJ = 125 °C t = 10 ms VR = 0 (di/dt)cr Maximum Ratings TC = 85 °C, 50-400 Hz (per phase) TVJ = 125 °C repetitive, IT = 50 A f=50Hz, tP=200µs VD=2/3VDRM IG=0.3 A non repetitive,IT = ITAVM 500 A/µs 1000 V/µs diG/dt=0.3A/µs (dv/dt)cr TVJ = 125 °C VD=2/3VDRM RGK= ∞, method 1 (linear voltage rise) PGM PGAVM VRGM TVJ TVJM Tstg VISOL TVJ = 125 °C tP=30µs ≤ 10 W IT =ITAVM ≤ 5 W 0.5 W 10 V -40... + 125 125 °C °C -40... + 125 °C 50/60 Hz, RMS t = 1 min 2500 V∼ IISOL ≤ 1 mA 3000 V∼ 1.5 - 2.0 14 - 18 46 Nm lb.in. g tP=300µs t=1s Md Mounting torque (M4) Weight typ. Features • • • • • • Thyristor controller for AC (circuit W3C acc. to IEC) for mains frequency Isolation voltage 3000 V∼ Planar glass passivated chips Low forward voltage drop Leads suitable for PC board soldering UL Release applied Applications • • • • Switching and control of single and three phase AC circuits Light and temperature control Softstart AC motor controller Solid state switches Advantages • • • • • Easy to mount with four screws Space and weight savings Improved temperature and power cycling capability High power density Small and light weight Data according to IEC 60747 refer to a single thyristor unless otherwise stated 2005 POWERSEM reserves the right to change limits, test conditions and dimensions POWERSEM GmbH, Walpersdorfer Str. 53 D - 91126 Schwabach Phone: 09122 - 9764 - 0 FAX: 09122 - 9764 - 20 ECO-PACTM 3 Symbol Test Conditions Characteristic Value ID, I R VT VTO rT VGT TVJ = 125°C, VR = VRRM, VD=VDRM ≤ IT = 80 A, ≤ 1.64 V 0.85 V 11 mΩ TVJ = 25 °C For power-loss calculations only VD=6V 5 mA TVJ= 25°C ≤ 1.5 V TVJ=-40°C ≤ 1.6 V ≤ 100 mA IGT VD=6V TVJ= 25°C TVJ=-40°C ≤ 200 mA VGD IGD IL TVJ= 125°C VD=2/3VDRM ≤ 0.2 V TVJ= 125°C VD=2/3VDRM ≤ 5 mA TVJ= 25°C, tP=10µs, VD=6V ≤ 200 mA TVJ= 25°C, VD=6V, RGK= ∞ ≤ 150 mA TVJ= 25°C, VD=1/2VDRM ≤ 2 µs 150 µs per thyristor; DC per module per thyristor; DC 0.8 0.133 1.1 K/W K/W K/W per module 0.183 K/W 11.2 11.2 50 mm mm m/s² IG=0.3A, diG/dt=0.3A/µs IH tgd IG=0.3A, diG/dt=0.3A/µs tq TVJ= TVJM; IT=20A; tp=200µs;di/dt=-10A/µs VR=100V; dv/dt=15V/µs; VD=2/3VDRM RthJC RthJH ds dA a Creepage distance on surface (Pin to heatsink) Strike distance in air (Pin to heatsink) Max. allowable acceleration Package style and outline Dimensions in mm (1mm = 0.0394“) W3C W3H 2005 POWERSEM reserves the right to change limits, test conditions and dimensions POWERSEM GmbH, Walpersdorfer Str. 53 D - 91126 Schwabach Phone: 09122 - 9764 - 0 FAX: 09122 - 9764 - 20