Solid State Relays Analog Full Cycle Switching Type RN.F... • • • • • • • • Product Description The analog switching relay provides a number of full cycles, evenly distributed over a fixed period, depending of the control input. The input of 4-20 mA or 0-10 VDC respectively, corresponds to zero and full output within a period of 1.28 s @ 50 Hz (1.07 s @ 60 Hz). This principle makes the transfer characteristics fully linear. The AC solid state relay, 1- and 2 poles Analog switching for resistive loads (heating) 4-20 mA or 0-10 V controls Rated operational current 30 and 50 AACrms Rated operational voltage up to 480 VAC LED-indication for normal operation and alarm status IP 20 protection DIN-rail mountable Ordering Key principle operates with zero switching, thus ensuring a reduced level of radiated and wire conducted noise. The 2pole type has alarm LED indication by loss of master phase. The analogue Full Cycle Switching is not recommended for light control due to light-flickering. RN 1 F 40 V 30 Solid State Relay Number of poles Switching type Rated operational voltage Control signal Rated operational current Type Selection, 1-Pole Rated operational voltage Control input Control supply Rated operational current 30 A 50 A 120 VAC 4-20 mA 0-10 VDC 12-32 VDC, 24 VAC RN 1F12I30 RN 1F12V30 RN 1F12I50 RN 1F12V50 230 VAC 4-20 mA 0-10 VDC 12-32 VDC, 24 VAC RN 1F23I30 RN 1F23V30 RN 1F23I50 RN 1F23V50 480 VAC 4-20 mA 0-10 VDC 12-32 VDC, 24 VAC RN 1F48I30 RN 1F48V30 RN 1F48I50 RN 1F48V50 Type Selection, 2-Pole Rated operational voltage Control input Control supply Rated operational current 30 A 50 A 120 VAC 4-20 mA 0-10 VDC 12-32 VDC, 24 VAC RN 2F12I30 RN 2F12V30 RN 2F12I50 RN 2F12V50 230 VAC 4-20 mA 0-10 VDC 12-32 VDC, 24 VAC RN 2F23I30 RN 2F23V30 RN 2F23I50 RN 2F23V50 480 VAC 4-20 mA 0-10 VDC 12-32 VDC, 24 VAC RN 2F48I30 RN 2F48V30 RN 2F48I50 RN 2F48V50 Specifications are subject to change without notice (04.02.00) 1 RN 1F General Specifications Operational voltage range Non-rep. peak voltage Varistor voltage Zero voltage turn-on Operational frequency range Power factor at rated voltage Average output power Output power resolution CE-marking Approvals RN.F12... RN.F23... RN.F48... 85 to 140 VAC 800 Vp 275 VAC < 10 V 45 to 65 Hz ≥ 0.9 0 to 100% 1/64 of 100% Yes CSA 85 to 265 VAC 800 Vp 275 VAC < 10 V 45 to 65 Hz ≥ 0.9 0 to 100% 1/64 of 100% Yes CSA 190 to 530 VAC 1000 Vp 510 VAC < 20 V 45 to 65 Hz ≥ 0.9 0 to 100% 1/64 of 100% Yes CSA Input Specifications RN.F..I.. Current controlled input Control current range Allowable input current Reverse polarity protected Voltage drop 4 - 20 mA 50 mA Yes 10 VDC @ 20 mA RN.F..V.. Voltage controlled input Supply voltage range Supply current Control voltage range Control input current 21 - 27 VAC, 12 - 32 VDC 30 mA @ 24 VAC/32 VDC 0 - 10 V 0.1 mA @ 10 VDC Output Specifications Rated operational current AC1 @Ta=30°C “ @Ta=40°C “ @Ta=50°C “ @Ta=60°C Zero crossing detection Min. operational current (per pole) Rep. overload current t=1 s (Tj init.=25°C) Non-rep. surge current t=10 ms (Tj init.=25°C) Off-state leakage current, @ rated voltage and frequency (Tj.=125°C, max.) I2t for fusing t=1 to 10 ms Critical dV/dt off-state RN.F..30 RN.F..50 30 A 25 A 23 A 20 A Yes 500 mA 50 A 50 A 38 A 30 A Yes 500 mA 55 A (rms) 125 A (rms) < 250 Ap < 600 Ap < 6 mA 310 A2s 500 V/µs < 6 mA 1800 A2s 500 V/µs Thermal Specifications Operational temperature Storage temperature Junction temperature Rth junction to ambient (AC load) 2 RN.F..30 RN.F..50 -20° to +70°C (-4° to +158°F) -20° to +100°C (-4° to +212°F) < 125°C (257°F) 2.8 K/W -20° to +70°C (-4° to +158°F) -20° to +100°C (-4° to +212°F) < 125°C (257°F) 1.7 K/W Specifications are subject to change without notice (04.02.00) RN 1F Housing Specifications Insulation Mounting Weight with RHN1 Weight with RHN2 Housing material LED window material Base plate Potting compound Terminals Control terminals nominal Rated imp. withstand voltage Input to output Rated imp. withstand voltage Output to heatsink Min. Mounting torque max. Power terminals nominal Min. Mounting torque max. Heatsink compound used DIN-rail 35 mm 470 g 780 g Glass reinforced noryl SE1GFN1 PC Lexan 141R Aluminium, nickel plated Polyurethane, Casco Nobel Screw with captive wire clamp 4 mm2 or 2 x 2.5 mm2 AWG 12 or 2 x AWG 14 0.5 mm2, AWG 20 0.6 Nm 10 mm2 or 2 x 6 mm2 AWG 6 or 2 x AWG 10 1 mm2, AWG 16 2.0 Nm Dow Corning 340 4000 Vimp 4000 Vimp Environment Specifications Humidity max. 95%, no condensation Dimensions Dimensions with RHN 1 (30 A) (H x W x D) 120 x 45 x 110 mm Dimensions with RHN 2 (50 A) (H x W x D) 120 x 90 x 110 mm Dimensions 89 103 70 120 4 71,6 37 71,6 37 45 93 45 20 4 20 70 120 60 60 30 30 103 RHN1 72 33,7 Note: all dimensions in mm Note: all dimensions in mm RHN2 Wiring Diagrams Current Control 4 - 20 mA + L1 T1 Single-pole relay Voltage Control _ A 1 A2 0 - 10 VDC + 4 - 20 mA Current Control _ L1 A1 A2 T1 A3 A4 Control Supply Specifications are subject to change without notice (04.02.00) + 0 - 10 VDC Voltage Control _ + _ L1 L2 A 1 A2 L1 L2 T1 T2 T1 T 2 A3 A4 Double-pole relay A1 A 2 Control Supply 3 RN 1F Terminal Layout 1-pole RN.. 2-pole current controlled input 2-pole RN.. A1 L1 Functional Diagrams A2 L1 L2 A1 A2 Master VAC/VDC VAC / VDC(A3, A4 only used for voltage control) A3 A4 L1 + A1 control signal _ A 2 X X C/V T1 Slave (2-pole version) X A3 T1 A4 T1 T2 A3 L2 X A4 T2 Shown with RHN1 Applications Single and double pole relay application Line-Neutral Double pole relay in 3-phase application Star and delta application (Economy Switching only) L1 L2 L3 L1 L2 N 4 Specifications are subject to change without notice (04.02.00)