ETC RR3PI110AC

General purpose 10 amp Plug In Power Relay, available in
2PCO and 3PCO
■ Large selection of models with different operating options
■ Arc barriers prevent flashover between contacts
■ Manual operator for circuit testing – colour coded for AC/DC
identification
■ Mechanical flag indicator showing armature operation
■ Gold flashed contacts
■ UL, CSA and VDE approvals
RR
M New
od
els
Plug In Power Relay
Options and ordering codes
RR
2
PI
230VAC
General purpose
power relay
For coil voltages
see table
2 pole changeover
2
I
Flag indicator
3 pole changeover
3
X
No flag indicator
R
LED indication
N
Flag and LED
P
Manual operator
X
No manual operator
PRICE
INFORMATION
AND ORDERING
Specifications
Resistive
10A @ 250V AC/30V DC
Rated load
Rated current1
Maximum switching voltage
Maximum switching capacity
Minimum switching capacity
Contact resistance (initial)
Operate time
Release time
Maximum operate frequency
Insulation class
Dielectric strength (Coil – Contact)
(Between adjacent Contacts)
(Contact Gap)
Ambient operating temperatures1
Mechanical ser vice life
Electrical ser vice life1
Protection degree
Contact material
Voltage range
Must release voltage
Power consumption
Coil wire class
1
To IEC 255-1-00, IEC 255-0-20
2
IEC 255-7 (Cat.3)
Inductive
7A @ 250V AC/30V DC
10A
250V AC/125V DC
2500VA, 300W @ 30V DC, 50W @ 125V DC
1750VA, 210W @ 30V DC, 35W @ 125V DC
4V 25mA, 100V 1mA
30mΩ2 100mΩ3
20 m sec max
20 m sec max
1800 ops/hr at maximum rated load
Group B250 (according to DIN VDE0110)
2500V AC 50/60 Hz for 1 minute
2000V AC 50/60 Hz for 1 minute
1000V AC 50/60 Hz for 1 minute
-40 to + 70˚C
20 million ops minimum
100,000 ops at rated load
IP10
AgCdO/Au 0.2um
80 - 110%
15% AC coil/10% DC coil
2.5 VA AC 1.35 watts DC
F (155˚C)
3
IEC 255-7 (Cat.2)
Coil Data
Rated
Voltage
12
24
110
230
A.C. Coils
Coil Resistance Ohms
20
88
2000
7900
D.C. Coils
Rated Current
190mA
95mA
20mA
10mA
Coil Resistance Ohms
110
430
–
–
Rated Current
109mA
56mA
–
–
RR
Switching characteristics
N
107
A
10
106
7
5
4
105
3
2
104
0
0.5
1
1.5
2
2.5
3
KVA
Electrical life as a function of rated power for AC 50-60Hz
(non-inductive circuit) at 1800 ops/h
1
0.7
0.5
0.4
1
0.3
2
0.2
0.1
20
Power reduction factor in relation to cos ø of
inductive load
Dimensions (mm)
100
V
Value of current broken by contact as a function of contact voltage.
Resistive load DC.
1 – resistive load T=0 ms
2 – inductive load T=40 ms.
Terminal arrangement
2 C/O
2 C/O
3 C/O
3 C/O
PRICE
INFORMATION
AND ORDERING