General purpose 10 amp Plug In Power Relay, available in 2PCO and 3PCO ■ Large selection of models with different operating options ■ Arc barriers prevent flashover between contacts ■ Manual operator for circuit testing – colour coded for AC/DC identification ■ Mechanical flag indicator showing armature operation ■ Gold flashed contacts ■ UL, CSA and VDE approvals RR M New od els Plug In Power Relay Options and ordering codes RR 2 PI 230VAC General purpose power relay For coil voltages see table 2 pole changeover 2 I Flag indicator 3 pole changeover 3 X No flag indicator R LED indication N Flag and LED P Manual operator X No manual operator PRICE INFORMATION AND ORDERING Specifications Resistive 10A @ 250V AC/30V DC Rated load Rated current1 Maximum switching voltage Maximum switching capacity Minimum switching capacity Contact resistance (initial) Operate time Release time Maximum operate frequency Insulation class Dielectric strength (Coil – Contact) (Between adjacent Contacts) (Contact Gap) Ambient operating temperatures1 Mechanical ser vice life Electrical ser vice life1 Protection degree Contact material Voltage range Must release voltage Power consumption Coil wire class 1 To IEC 255-1-00, IEC 255-0-20 2 IEC 255-7 (Cat.3) Inductive 7A @ 250V AC/30V DC 10A 250V AC/125V DC 2500VA, 300W @ 30V DC, 50W @ 125V DC 1750VA, 210W @ 30V DC, 35W @ 125V DC 4V 25mA, 100V 1mA 30mΩ2 100mΩ3 20 m sec max 20 m sec max 1800 ops/hr at maximum rated load Group B250 (according to DIN VDE0110) 2500V AC 50/60 Hz for 1 minute 2000V AC 50/60 Hz for 1 minute 1000V AC 50/60 Hz for 1 minute -40 to + 70˚C 20 million ops minimum 100,000 ops at rated load IP10 AgCdO/Au 0.2um 80 - 110% 15% AC coil/10% DC coil 2.5 VA AC 1.35 watts DC F (155˚C) 3 IEC 255-7 (Cat.2) Coil Data Rated Voltage 12 24 110 230 A.C. Coils Coil Resistance Ohms 20 88 2000 7900 D.C. Coils Rated Current 190mA 95mA 20mA 10mA Coil Resistance Ohms 110 430 – – Rated Current 109mA 56mA – – RR Switching characteristics N 107 A 10 106 7 5 4 105 3 2 104 0 0.5 1 1.5 2 2.5 3 KVA Electrical life as a function of rated power for AC 50-60Hz (non-inductive circuit) at 1800 ops/h 1 0.7 0.5 0.4 1 0.3 2 0.2 0.1 20 Power reduction factor in relation to cos ø of inductive load Dimensions (mm) 100 V Value of current broken by contact as a function of contact voltage. Resistive load DC. 1 – resistive load T=0 ms 2 – inductive load T=40 ms. Terminal arrangement 2 C/O 2 C/O 3 C/O 3 C/O PRICE INFORMATION AND ORDERING