® ® SHM-12 Ultra-Fast, 12-Bit Linear Monolithic Sample-Hold Amplifiers IN N O VA T IO N a n d E X C E L L E N C E FEATURES • Fast acquisition time: 10ns to ±0.1% 15ns to ±0.024% 20ns to ±0.012% • ±0.006% Nonlinearity • 65µVrms output noise • 120MHz small signal bandwidth • 55MHz full power bandwidth • –80dB feedthrough • 1ps Aperture jitter • 250mW power dissipation • Low cost INPUT/OUTPUT CONNECTIONS (CLCC and SOIC-20 Packages) GENERAL DESCRIPTION The SHM-12 is an extremely high-speed and accurate monolithic sample-and-hold amplifier designed for fast data acquisition applications. The SHM-12 is accurate (±1LSB at 12 bits over the full military temperature range) and is very fast (10ns and 15ns acquisition times to accuracies of 10 and 12bits, respectively). With this high performance and a full power bandwidth of 55MHz, the SHM-12 is an ideal device for driving flash and high-resolution subranging A/D converters. A careful design optimizes the device for accuracy and speed over the full military temperature range. The droop rate is a low ±0.5mV/µs. The 30mA output current and guaranteed specifications for a 100Ω load provide high drive capability. Operating from ±5V supplies, the SHM-12 consumes only 250mW of power. –5V SUPPLY FUNCTION PIN FUNCTION 1 2 3 4 5 6 7 8 9 10 –5V SUPPLY –5V SUPPLY NOT CONNECTED ANALOG INPUT –5V SUPPLY DO NOT CONNECT –5V SUPPLY DO NOT CONNECT –5V SUPPLY –5V SUPPLY 20 19 18 17 16 15 14 13 12 11 +5V SUPPLY SAMPLE/HOLD SAMPLE/HOLD +5V SUPPLY GROUND EXT. CAPACITOR GROUND +5V SUPPLY +5V SUPPLY ANALOG OUTPUT The SHM-12 is built using a fast complementary bipolar process. The device is available in both military and industrial temperature ranges. The SHM-12 is packaged in a 20-pin plastic SOIC or ceramic LCC. EXTERNAL HOLD CAPACITOR 1, 2, 5, 7, 9, 10 ANALOG INPUT PIN +5V SUPPLY 15 12, 13, 17, 20 4 +1 CH 15pF +1 11 ANALOG OUTPUT 3 NOT CONNECTED SAMPLE/HOLD SAMPLE/HOLD 18 SWITCH DRIVE 6, 8 DO NOT CONNECT 19 14, 16 GROUND Figure 1. SHM-12 Functional Block Diagram DATEL, Inc., 11 Cabot Boulevard, Mansfield, MA 02048-1151 (U.S.A.) • Tel: (508) 339-3000 Fax: (508) 339-6356 • For immediate assistance (800) 233-2765 ® ® SHM-12 ABSOLUTE MAXIMUM RATINGS PARAMETERS PERFORMANCE (Cont.) LIMITS UNITS +5V Supply –5V Supply Analog Input 0 to +6 0 to –6 +5V Supply –1 –5V Supply +1 Continuous Output Current ±50 Digital Inputs <Supply Voltages Junction Temperature +175 Lead Temperature (10 seconds) +300 Output shorted to any supply will cause permanent damage. Acquisition Time (±0.1%, ±1V) –40 to +85°C –55 to +125°C Hold Mode Settling (±0.012%) –40 to +85°C –55 to +125°C Hold Mode Settling (±0.024%) –40 to +85°C –55 to +125°C Hold Mode Settling (±0.05%) –40 to +85°C –55 to +125°C Hold Mode Settling (±0.1%) –40 to +85°C –55 to +125°C Slew Rate Full Power Bandwidth (±1V) Small Signal Bandwidth Output Noise, Hold Mode Feedthrough (2V Step) Droop Rate +25°C –40 to +85°C –55 to +125°C Volts Volts Volts Volts mA Volts °C °C FUNCTIONAL SPECIFICATIONS (Apply over the operating temperature range using a 100Ω resistive load, 10pF capacitive load, ECL digital input levels, a 47pF external hold capacitor, and ±5V nominal supplies, unless otherwise specified.) INPUTS MIN. TYP. Input Voltage Range Input Impedance Digitals Inputs (Balanced ECL) Logic Levels Logic 1 Logic 0 Logic Loading Logic 1 Logic 0 –1.5 0.3 — 1 MAX. UNITS +1.5 — Volts MΩ –1.5 –2.5 — — +1.8 +0.8 Volts Volts — — +10 –30 +50 –150 µA µA –1.5 ± 30 — — — — 0.3 — +1.5 — 1 50 Volts mA Ω pF Power Supply Range +5V Supply –5V Supply Power Supply Current +5V Supply –5V Supply Power Dissipation Power Supply Rejection Ratio PERFORMANCE Nonlinearity (±1V) +25°C –40 to +85°C –55 to +125°C Sample Mode Offset +25°C –40 to +85°C –55 to +125°C Pedestal +25°C –40 to +85°C –55 to +125°C Gain, +25°C Gain Drift (±1V) –40 to +85°C –55 to +125°C Aperture Delay –40 to +85°C –55 to +125°C Aperture Jitter –40 to +85°C –55 to +125°C Harmonic Distortion (±1V) dc to 1MHz dc to 10MHz +25°C –40 to +85°C –55 to +125°C Acquisition Time (±0.012%, ±1V) –40 to +85°C –55 to +125°C Acquisition Time (±0.024%, ±1V) –40 to +85°C –55 to +125°C Acquisition Time (±0.05%, ±1V) –40 to +85°C –55 to +125°C TYP. MAX. UNITS — — 10 10 20 20 ns ns — — 10 10 — — ns ns — — 7 7 18 18 ns ns — — 6 6 15 15 ns ns — — ±220 35 50 — — 5 5 ±350 55 120 65 –80 12 12 — — — — — ns ns V/µs MHz MHz µVrms dB — — — ±0.5 ±2 ±2.5 ±1.5 ±5 ±10 mV/µs mV/µs mV/µs +4.5 –5.5 +5 –5 +5.5 –4.5 Volts Volts +17 –17 170 40 +25 –25 250 60 +30 –30 300 — mA mA mW dB –40 –55 –65 — — — +85 +125 +150 °C °C °C POWER SUPPLY REQUIREMENTS OUTPUTS Output Voltage Range Output Current • Output Impedance (dc) Stable Capacitive Load MIN. ENVIRONMENTAL — — — ±0.006 — — — ±0.024 ±0.024 % % % — — — ±12 — — — ±20 ±30 mV mV mV — — — +0.98 ±3 — — +0.995 — ±20 ±20 — mV mV mV V/V — — — — ±20 ±30 ppm/°C ppm/°C — — 2 2 — — ns ns — — 1 1 — — ps rms ps rms — –75 — dB — — — –62 — — — –56 –54 dB dB dB — — 20 30 — — ns ns — — 15 25 30 40 ns ns — — 12 15 25 30 ns ns Operating Temp. Range, Case SHM-12S, SHM-12L SHM-12LM Storage Temperature Range Package Type SHM-12S SHM-12L, SHM-12LM 20-Pin plastic SOIC 20-Pin ceramic LCC Footnotes: • Short circuit protection at ±50mA. TECHNICAL NOTES The SHM-12 employs an open loop architecture to achieve its superior high-speed characteristics. The first stage buffer amplifier incorporates the sample-and-hold switch. This allows for a fast acquisition time which is not limited by slew current like the traditional Schottky diode bridge switch. The output amplifier uses a closed loop voltage feedback design which provides a low (0.3Ω, typical) output impedance. Gain and linearity are not affected by heavy loads. The design has been optimized to achieve the high accuracy associated with fast transient responses over the military temperature range. During the track-to-hold transient, the integral nonlinearity is not affected and the pedestal remains constant over the full ±1.5V input range. An innovative circuit design ensures an extremely low droop rate. An external hold capacitor can be added to the 15pF internal hold capacitor to obtain a lower droop rate (the droop rate is proportional to the inverse of the total hold capacitor value) without increasing transient response times by more than a few ns. The external hold capacitor should not exceed 100pF. 2 ® ® SHM-12 GROUNDING AND LAYOUT Locate the bypass capacitors as close to the unit as possible. Obtaining fully specified performance from the SHM-12 requires careful attention to pc-board layout and power supply decoupling. For best performance, controlled impedance transmission line techniques, such as microstrip, should be used. Mount all components as close to the required pins as possible. It is strongly recommended that the SHM-12 not be socket-mounted. For optimal performance, tie all grounds directly to a large analog ground plane beneath and around the package. Bypass all power supplies to ground with 10µF tantalum capacitors in parallel with 0.1µF ceramic capacitors. 50Ω SHM-12 SAMPLE / HOLD 1 –5V SUPPLY SAMPLE / HOLD 2 0.1µF –5V SUPPLY 5 –5V SUPPLY 50Ω 7 EXTERNAL HOLD CAPACITOR –5V SUPPLY GROUND –5V SUPPLY +5V SUPPLY +5V SUPPLY 10µF 17 C HO LD 15 Refer to Table 1 for optional HOLD capacitor value. 14, 16 9 0.1µF HOLD 0.1µF +5V SUPPLY +5V SUPPLY INPUT SAMPLE 18 20 4 ANALOG INPUT 50Ω 19 10 0.1µF 13 12 11 + –5V SUPPLY 0.1µF OUTPUT Pin 3 is not connected; do not connect pins 6 and 8. 0.1µF ANALOG OUTPUT 10µF R Load 100Ω 0.1µF +5V –5V Figure 2. SHM-12 Simplified Connection Diagram -0.8 V HOLD SAMPLE HOLD -1.8 V -0.8 V SAMPLE SAMPLE HOLD -1.8 V +1 V Acquisition Time to ±0.024% ANALOG INPUT -1 V 15ns typ. +1 V 7ns typ. ANALOG OUTPUT -1 V 7ns typ. Feedthrough -80dB Track-to-hold Settling to ±0.024% 15ns typ. Figure 3. SHM-12 Control and Timing 3 ® ® SHM-12 Evaluation Board for CLCC-20 Version 0.1µF –5V SUPPLY 16, 17, 18, 19 130Ω SAMPLE SHM-12 1, 2 –5V SUPPLY 0.1µF SAMPLE / HOLD ANALOG INPUT 20 4 51Ω +5V SUPPLY INPUT EXTERNAL HOLD CAPACITOR 5, 7 GROUND –5V SUPPLY 0.1µF +5V SUPPLY +5V SUPPLY –5V SUPPLY 11, 12, 15 GROUND 1, 2, 3, 4 9, 10 130Ω 82Ω 19 OUTPUT –5V SUPPLY 18 82Ω 17, 20 15 C HOLD 14, 16 CHOLD = 100pF; Refer to Table 1. +5V SUPPLY 0.1µF 12 11 0.1µF GROUND PLANE Figure 4. SHM-12 Evaluation Board Schematic Table 1. Optional External HOLD Capacitor SHM-12L, -12S SHM-12LM Operating Temperature Range –40 to +85°C –55 to +125°C 4 HOLD 13 0.1µF 13 0.1µF Model 14 SAMPLE / HOLD Type of HOLD Capacitor (Ceramic, ≤100pF, ±10%) Type I or II, NPO or X7R Type I or NPO 6, 7, 8, 9, 10 ANALOG OUTPUT 5 ® ® SHM-12 INCHES (mm) 0.43 (11) PLASTIC STANDOFF 0.13 (3.3) 0.100 (2.54) 20 19 C2 R1 18 C3 C7 C4 R4 14 R3 13 12 20 2 19 3 3 18 4 17 5 16 6 15 7 14 8 13 9 12 10 11 5 C6 R6 CEXT 15 1 2 C5 C1 16 1 4 17 R5 6 7 8 9 0.018 (0.45) 10 11 (TOP VIEW) 0.85 (21.59) (BOTTOM VIEW) 0.95 (24.13) Figure 5. SHM-12 Evaluation Board Dimensions SHM-12 Evaluation Board Connections PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 FUNCTION GROUND GROUND GROUND GROUND ANALOG OUTPUT +5V SUPPLY +5V SUPPLY +5V SUPPLY +5V SUPPLY +5V SUPPLY –5V SUPPLY –5V SUPPLY HOLD SAMPLE –5V SUPPLY –5V SUPPLY –5V SUPPLY –5V SUPPLY –5V SUPPLY ANALOG INPUT 5 1.10 (27.94) ® ® SHM-12 MECHANICAL DIMENSIONS TOP VIEW A SOIC-20 Package J 20 L 11 C SYMBOL A B C D E F G H J K L B K H 1 10 E D G INCHES MIN. MAX. 0.500 0.510 0.400 0.410 0.292 0.299 0.014 0.019 0.0500 BSC 0.0039 0.0112 0° 8° 0.020 0.040 0.097 0.104 0.010 0.020 0.0091 0.0125 MILLIMETERS MIN. MAX. 12.70 12.95 10.16 10.41 7.40 7.60 0.35 0.48 1.27 BSC 0.10 0.30 0° 8° 0.51 1.02 2.46 2.64 0.25 0.51 0.23 0.32 F A CLCC-20 Package D B SYMBOL A B C D E F G H C E G PIN 1 INDEX (H x 45° 3 PLACES) H INCHES MIN. MAX. 0.064 0.100 0.045 0.055 0.075 REF 0.342 0.358 0.022 0.028 0.020 REF 0.050 BSC 0.040 REF MILLIMETERS MIN. MAX. 1.63 2.54 1.14 1.40 1.91 REF 8.69 9.09 0.56 0.71 0.51 1.27 BSC 1.02 F (F x 45°) BOTTOM VIEW ORDERING INFORMATION MODEL NUMBER PACKAGE SHM-12S SHM-12L SHM-12LM EVB-SHM12 TEMPERATURE RANGE SOIC-20 –40 to +85°C CLCC-20 –40 to +85°C CLCC-20 –55 to +125°C Evaluation Board (with SHM-12LM) Contact DATEL for availability of high-reliability models. ® ® IN N O VA T IO N a n d E X C E L L E N C E DATEL, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 Internet: www.datel.com E-mail:[email protected] Data Sheet Fax Back: (508) 261-2857 ISO 9001 R E G I S T E R E D DS-0310 10/96 DATEL (UK) LTD. Tadley, England Tel: (01256)-880444 DATEL S.A.R.L. Montigny Le Bretonneux, France Tel: 1-34-60-01-01 DATEL GmbH München, Germany Tel: 89-544334-0 DATEL KK Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-354-2025 DATEL makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. The DATEL logo is a registered DATEL, Inc. trademark.