MEANWELL SKM15A-12

SKM15
15W DC-DC Regulated Single Output Converter
series
Features :
1" 1" compact size
2:1 wide input range
High efficiency up to 88%
1500VDC I/O isolation
Built-in remote ON/OFF control
Built-in trimming output( 10%)
Built-in EMI filter
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Six-sided shield metal case
100% burn-in test
Low cost / High reliability
Approvals: FCC / CE
2 years warranty
SPECIFICATION
ORDER NO.
SKM15A-05 SKM15B-05 SKM15C-05 SKM15A-12 SKM15B-12 SKM15C-12 SKM15A-15 SKM15B-15 SKM15C-15
DC VOLTAGE
5V
12V
15V
CURRENT RANGE
300 ~ 3000mA
125 ~ 1250mA
100 ~ 1000mA
RATED POWER
15W
60mVp-p
60mVp-p
RIPPLE & NOISE (max.) Note.2 50mVp-p
OUTPUT
LINE REGULATION
Note.3
0.5%
LOAD REGULATION
Note.4
0.5%
2.0%
VOLTAGE ACCURACY
400KHz typ.
SWITCHING FREQUENCY
EXTERNAL CAPACITANCE LOAD (max.) 1000uF
EXTERNAL TRIM Adj. RANGE(Typ.) 10%
VOLTAGE RANGE
A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 75VDC
87%
86%
87%
86%
87%
86%
88%
88%
87%
Full load 1500mA
750mA
380mA
1500mA
750mA
380mA
1500mA
750mA
380mA
No load
55mA
35mA
35mA
25mA
15mA
35mA
25mA
15mA
EFFICIENCY (Typ.)
DC CURRENT
INPUT
Fuse recommended
PROTECTION
110% ~ 180% rated output power
OVER CURRENT
PROTECTION
(Note. 5)
80mA
Pi network
Power ON : R.C ~ -Vin > 2.5VDC or open circuit ; Power OFF : R.C ~ -Vin < 0.5VDC or short
FILTER
REMOTE CONTROL
Protection type : Hiccup mode, recovers automatically after fault condition is removed
All output equipped with short circuit
SHORT CIRCUIT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
115% ~ 150% rated output voltage
OVER VOLTAGE
Protection type : Clamp by diode, recovers automatically after fault condition is removed
-40 ~ +80 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -55 ~ +100 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
TEMP. COEFFICIENT
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
VIBRATION
I/P-O/P:1.5KVDC
WITHSTAND VOLTAGE
I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH
SAFETY & ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022 Class A, FCC part 15 Class A
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A
EMS IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
400Khrs min. MIL-HDBK-217F(25
25.4*25.4*9.9 mm or 1"*1"*0.39" inch (L*W*H)
WEIGHT
15g
Unit:mm(inch)
12.7
(0.50)
10.16
(0.40)
10.16
(0.40)
20.32
(0.80)
25.40
(1.00)
6
5
Derating Curve
Pin Configuration
Mechanical Specification
1.0 DIA
(0.040 0.005)
4
Pin No. Output
Pin No. Output
1
+Vin
4
2
-Vin
5
Trim
3
R.C.
6
+Vout
-Vout
100
External Output Trimming
BOTTOM
VIEW
2
2
1
2.54
(0.10)
25.40
(1.00)
-Vin
+Vout
2.54
(0.10)
5.8
(0.23)
-Vout
9.9
(0.39)
50
6
3
7.62
(0.30)
5.08
(0.20)
NOTE
)
MTBF
DIMENSION
LOAD (%)
OTHERS
4
500K
LOAD
VR
-40
0
25
50 60
80
100
VR
1
+Vin
TRIM
5
Ta (
UP
DOWN
)
TRIMPOT
1.All parameters are specified at normal input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
File Name:SKM15-SPEC 2011-03-31