ETC SM170220

Current and Voltage Controls
3-Phase Voltage Sequence Control
Type SM 170
• 3-phase monitoring relay for phase
sequence/phase loss
• Measures when all 3 phases are present and
have the correct phase sequence
• Output: 10 A SPDT relay
• Plug-in type module
• S-housing
• LED-indication for power supply and output ON
• Power supply is the 3-phased measuring voltage
Product Description
Ordering Key
3-phase plug-in monitoring
and phase sequence/phaseloss relay. Frequently used to
prevent a 3-phase motor from
Housing
Function
Output
Type
Power supply
running on only 2 phases or
to secure the right phase sequence when connecting a
load to the mains.
SM 170 400
Type Selection
Plug
Output
Supply: 220 VAC
Supply: 380 VAC
Supply: 400 VAC
Supply: 415 VAC
Circular
SPDT
SM 170 220
SM 170 380
SM 170 400
SM 170 415
Input Specifications
Output Specifications
Input
Pin 5
Pin 6
Pin 7
Pin 11
Output
Rated insulation voltage
Phase L1
Phase L2
Phase L3
Neutral (optional connection)
measures on own supply
Supply Specifications
Power supply AC types
Rated operational voltage
Through pins 5, 6, 7 & 11
Overvoltage cat. III (IEC 60664)
(IEC 60038)
220
380
400
415
Internal measuring circuit is
connected to pins 5 & 7
3 x 220 VAC ± 15%, 45 to 65 Hz
3 x 380 VAC ± 15%, 45 to 65 Hz
3 x 400 VAC ± 15%, 45 to 65 Hz
3 x 415 VAC ± 15%, 45 to 65 Hz
Voltage interruption
Dielectric voltage
Rated impulse withstand volt.
≤ 40 ms
None (supply/elect.)
4 kV (1.2/50 µs) (line/neutral,
line/line), direct connection
to electronics
2.5 VA
Rated operational power
Specifications are subject to change without notice
Contact ratings (AgCdO)
Resistive loads
AC 1
DC 1
or
Small inductive loads AC 15
DC 13
Mechanical life
Electrical life
AC 1
Operating frequency
Dielectric strength
Dielectric voltage
Rated impulse withstand volt.
SPDT relay
250 VAC (rms)
(cont./elect.)
µ (micro gap)
10 A/250 VAC (2500 VA)
1 A/250 VDC (250 W)
10 A/25 VDC (250 W)
2.5 A/230 VAC
5 A/24 VDC
≥ 30 x 106 operations
≥ 2.5 x 105 operations
(at max. load)
≤ 7200 operations/h
≥ 2 kVAC (rms) (cont./elect.)
4 kV (1.2/50 µs) (cont./elect.)
(IEC 60664)
1
SM 170
General Specifications
Reaction time
Indication for
Power supply ON
Output ON
Environment
Degree of protection
Pollution degree
Operating temperature
Storage temperature
Weight
Approvals
τ = 0.5 s, worst case reaction time may be up to 5 x τ
LED, green
LED, red
(IEC 60947-1)
IP 20 B (IEC 60529)
(IEC 60664)
1: SM 170 380/400/415
2: SM 170 220
-20° to +50°C (-4° to +122°F)
-50° to +85°C (-58° to +185°F)
200 g
UL, CSA, SEV
(SEV only 3 x 220 VAC)
Mode of Operation
The relay measures on its own
3-phased power supply and
operates when all phases are
present and the phase sequence is correct.
Example 1
The relay is for monitoring
that the power supply has a
correct phase sequence and
that all phase voltages are
present. The relay is a 3-phase
power supply monitoring relay.
Example 2
The relay releases in case of
interruption of one of the
phases, provided that the
voltage regenerated by electric motors on the interupted
phase does not exceed 70%
of the nominal voltage. If it
exceeds this value the connection cannot be recommended (see description ex.
3). The regenerated voltage
will be a lower phase voltage
combined with a phase angle
failure.
Example 3
If the value of the regenerated voltage is slightly higher
than 70% of the nominal voltage, the relay releases when
neutral is connected to pin 11
as sensitivity is improved.
Wiring Diagrams
Example 1
Example 2 and 3
Accessories
Sockets◊
Hold down spring◊
Mounting rack
Socket covers
Front mounting bezel
S 411
HF
SM 13
BB 4
FRS 2
For further information refer to "Accessories".
Operation Diagram
Phase L1, pin 5
Phase L2, pin 6
Phase L3, pin 7
Relay ON
2
Specifications are subject to change without notice