XPPOWER SMM400PS05-C

AC-DC
400 Watts
xppower.com
SMM Series
•
Industrial, IT & Medical Approvals
•
Low Profile for 1U Applications
•
Optional Current Share & AC Fail
•
Output Voltages from 3.3 V to 54 V
•
Enclosed with Internal Fan & U-Channel Versions
•
Class B Conducted Emissions
•
Optional Molex Connectors
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
General
•
•
•
•
Power Factor
•
Earth Leakage Current •
UVLO
•
Input Protection
•
90-264 VAC (120-370 VDC)
47-63 Hz
6.35 A at 90 VAC, full load
35 A peak max (cold start at 240 VAC
& full load)
Meets EN61000-3-2
<300 µA max at 264 VAC/60 Hz
Shut down when 75 VAC <Vin <85 VAC
& turns on when Vin >86 VAC
Internal 8 A fuse in line and neutral
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Hold Up Time
Line Regulation
Load Regulation
•
•
•
•
•
•
•
•
Over/Undershoot
Transient Response
•
•
Ripple & Noise
Overvoltage Protection
Overtemperature
Protection
Overload Protection
Short Circuit Protection
Remote Sense
•
•
•
Remote On/Off
• On = TTL Logic High or Open
Off = TTL Logic Low or Short
• Option ‘-I’ available on single output
models only - see note 4
• 12 V at 500 mA
Fan Drive
Isolation
Switching Frequency
Power Density
Signals
MTBF
Output
Current Share
Efficiency
•
•
•
3.3 to 54 VDC - see tables
±5% on V1, adjustable by user
Within 1% of stated output voltage
Single output: 1%, Dual output (V1): 10%
2 s max at 120 VAC
20 ms min at 80% full load
0.5%
±1% (single outputs),
±3% V1, ±7% V2 (dual outputs)
Not to exceed 5% of nominal voltage
5% max deviation, recovery to within 1%
in 500 µs for a 50% load change
<1% of nominal output voltage
>130% Vnom, recycle input to reset
Shuts down at +85 °C, measured internally
with auto recovery
110-140%
Constant current, auto recovery
Compensates for up to 0.5 V drop
(not available with current share)
• 3.3 & 5.0 V single output: 70% min,
All other single output: 80% min, Dual
outputs: 75% min at 230 VAC, full load
• 4000 VAC Input to Output, 1500 VAC Input
to Ground, 250 VDC Output to Ground
• 25 kHz for PWM stage,
60 kHz for PFC stage
• 6.25 W/In3 based on unit without cover/fan
• Current Share, Power Good, Current
Monitor & optional AC Fail (see note 5 available on single output models only)
• 140 kHrs at +25 °C per MIL-HDBK-217F
Environmental
Operating Temperature • -0 °C to +70 °C, derate linearly from
+50 °C to+ 70 °C at 2.5%/°C
Cooling
• Minimum 23 CFM airflow required for
maximum power output. ‘-C’ version has
built-in fan, others require 23 CFM air flow
to meet fan-cooled ratings
Operating Humidity
• 5-90% RH, non-condensing
Storage Temperature
• -20 °C to +85 °C
Vibration
• 5-50 Hz, acceleration 2 g, 3 minute
sweep, 60 mins in 3 axes
Shock
• 15 g 11 ms 1/2 sine wave, 3 times in 6
axes
Bump
• 15 g 6 ms 1/2 sine 4000 bumps in 3 axes
EMC & Safety
Emissions
Harmonic Currents
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
•
•
•
•
•
•
•
•
EN55011/22 Level B conducted & radiated
EN61000-3-2
EN61000-4-2, level 3 Perf Criteria A
EN61000-4-3, 3 V/m Perf Criteria A
EN61000-4-4, level 2 Perf Criteria A
EN61000-4-5, level 3 Perf Criteria A
EN61000-4-6, 3 V, Perf Criteria A
EN61000-4-11 70% UT for 10 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf Crit A, B, B (Perf Crit A, A, B with
85% load)
• UL60601-1, EN60601-1, EN60950-1:2001,
UL60950, CSA C22.2 No. 60950-1-03,
CSA C22.2 No. 601.1-M90
Output
Voltage(1)
3.3
5.0
12.0
15.0
18.0
24.0
27.0
36.0
48.0
54.0
3.3 V/12.0
3.3 V/24.0
5.0 V/12.0
5.0 V/24.0
12.0 V/24.0
Maximum Output Current
Total
Output Power
198 W
300 W
400 W
400 W
400 W
400 W
400 W
400 W
400 W
400 W
300 W
300 W
300 W
300 W
400 W
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
AC-DC
SMM-C
Models and Ratings
V1
60.00
60.00
33.34
26.60
22.20
16.70
14.80
11.10
8.30
7.40
40.00
40.00
40.00
40.00
25.00
Model
Number(2,3,4,5)
SMM400PS03-C†
SMM400PS05-C†
SMM400PS12-C†
SMM400PS15-C†
SMM400PS18-C
SMM400PS24-C†
SMM400PS27-C
SMM400PS36-C
SMM400PS48-C†
SMM400PS54-C
SMM400PD21-C
SMM400PD22-C
SMM400PD23-C
SMM400PD24-C
SMM400PD25-C
V2
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
25.00
12.50
25.00
12.50
12.50
A
A
A
A
A
Notes
1. Other output voltages available. Contact sales.
2. Standard input is screw terminal. For optional IEC320 input and on/off switch, add suffix ‘-D’ to model number.
3. Standard output is screw terminal. For optional Molex output connector, add suffix ‘-G’ to model number.
4. For current share option, add suffix ‘-I’ to model number (remote sense not available). This option also adds internal block diodes.
5. For AC fail option, add suffix ‘-L’ to model number (single output only). UVLO function is disabled. Output is low when input is <80 VAC, high (5 V) if input is >86 VAC.
6. When ordering place option suffixes in alphabetical order, e.g. SMM400PS24-CDI.
† Available from Farnell. See pages 204-206.
Mechanical Details
All dimensions in inches (mm).
Weight: 2.20 lbs (1.0 kg).
Max Screw Penetration: 0.15 (3.81) on bottom, 0.25 (6.35) on sides.
0.80 (20.3)
9.01 (228.6)
1.25 (31.8)
Dual
Single
C
C
B
B
1.50 (38.1)
‘-D’ OPTION
FAN
C
V2
VO -
VO -
V2
RTN
L N
C
C
B
B
VO +
0.88 (22.2)
RS+
RSREM ON/OFF
PG
RTN
‘-G’
OPTION
‘-G’
OPTION
3.25 (82.6)
0.50 (12.7)
4.00 (101.6)
B
C
5.00 (127.0)
B
VO +
STANDARD
FAN
RS+
RSREM ON/OFF
PG
ACF*
RTN
CSH
CMN
AC Inlet
V1
RTN
V1
7.01 (177.8)
1.60 (40.6)
1.60 (40.6)
TERMINAL BLOCK
M3 SCREW
3PINS 8.25mm CENTER
1.25 (31.8)
1.50 (38.1)
Mating Connectors
Signal Connector (Single): JST XHP-9
Signal Connector (Dual): JST XHP-5
Fan Connector: JST XHP-2
Crimp Terminals: SXH-002-P0.6
‘-G’ Optional Output: Molex No. 09-91-1600
Crimps: Molex Series 6838
B
B
C
C
7.01 (177.8)
0.80 (20.3)
TERMINAL BLOCK
M3.5 SCREW 6PINS
9.5mm CENTER
TERMINAL BLOCK
M3.5 SCREW 6PINS
9.5mm CENTER
Output Voltage
Range(1)
3.3
3.3
5.0
5.0
12.0
3.3
5.0
12.0
15.0
18.0
24.0
27.0
36.0
48.0
54.0
V/12.0
V/24.0
V/12.0
V/24.0
V/24.0
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
Maximum Output Current
Output 1
Output 2
Convection
Fan-Cooled
Convection
Fan-Cooled
45.00 A
60.00 A
45.00 A
60.00 A
20.80 A
33.34 A
16.60 A
26.60 A
13.90 A
22.20 A
10.40 A
16.70 A
9.20 A
14.80 A
6.90 A
11.10 A
5.20 A
8.30 A
4.60 A
7.40 A
30.00 A
40.00 A
16.70 A
25.00 A
30.00 A
40.00 A
8.30 A
12.50 A
30.00 A
40.00 A
16.70 A
25.00 A
30.00 A
40.00 A
8.30 A
12.50 A
16.70 A
25.00 A
8.30 A
12.50 A
Total Output Power
Convection
148.5 W
225.0 W
250.0 W
250.0 W
250.0 W
250.0 W
250.0 W
250.0 W
250.0 W
250.0 W
200.0 W
200.0 W
200.0 W
200.0 W
250.0 W
Fan-Cooled
198 W
300 W
400 W
400 W
400 W
400 W
400 W
400 W
400 W
400 W
300 W
300 W
300 W
300 W
400 W
Model
Number(2,3,4,5,6)
SMM400PS03
SMM400PS05
SMM400PS12
SMM400PS15
SMM400PS18
SMM400PS24
SMM400PS27
SMM400PS36
SMM400PS48
SMM400PS54
SMM400PD21
SMM400PD22
SMM400PD23
SMM400PD24
SMM400PD25
Notes
1. Other output voltages available. Contact sales.
2. For optional solid cover, add suffix ‘-A’ to the model number (external dimensions remain the same).
3. Standard input is screw terminal. For optional Molex input connector, add suffix ‘-F’ to model number.
4. Standard output is screw terminal. For optional Molex output connector, add suffix ‘-G’ to model number.
5. For current share option, add suffix ‘-I’ to model number (remote sense not available). This option also adds internal block diodes.
6. For AC fail option, add suffix ‘-L’ to model number (single output only). UVLO function is disabled. Output is low when input is <80 VAC, high (5 V) if input is >86 VAC.
7. When ordering place option suffixes in alphabetical order, e.g. SMM400PS24-GI.
Mechanical Details
All dimensions in inches (mm).
Weight: 2.20 lbs (1.0 kg).
Max Screw Penetration: 0.15 (3.81) on bottom, 0.25 (6.35) on sides.
0.80
1.25 (20.3)
(31.8)
C
C
Single
Dual
B
B
7.00 (177.8)
B
B
C
C
‘-G’
OPTION
‘-G’
OPTION
VO -
VO -
V2
VO +
L
VO +
RTN
3.25
(82.6)
L
RS+
RSREM ON/OFF
PG
RTN
V2
5.00 ±0.012
(127.0 ±0.3)
4.00
(101.6)
‘-F’ OPTION
FAN
RS+
RSREM ON/OFF
PG
ACF*
RTN
CSH
CMN
0.50
(12.7)
0.50
(12.7)
FAN
AC-DC
SMM
Models and Ratings
V1
RTN
V1
N
N
C
C
B
B
G
G
C:M O U
TERMINAL BLOCK
M3.5 SCREW 6PINS
9.5mm CENTER
8.00 (203.2)
0.5
(12.7)
1.60
(40.6) 1.25
(31.8) 0.80
(20.3)
Mating Connectors
Signal Connector (Single): JST XHP-9
Signal Connector (Dual): JST XHP-5
Fan Connector: JST XHP-2
Crimp Terminals: SXH-002-P0.6
‘-F’ optional input: Molex No. 09-91-0700
‘-G’ optional output: Molex No. 09-91-1600
Crimps: Molex Series 6838
Mounting holes B: 6-32
Mounting holes C: M4
7.00 (177.8)
B
B
C
C
TERMINAL BLOCK
M3.5 SCREW 6PINS
9.5mm CENTER
Remote On/Off
Current Monitor
Single Output Only
ON/OFF
CN3 Pin 3, control connector
CMN
CN3 Pin 8, control connector
PSU
PSU
Return
CN3 Pin 6, control connector (single output)
CN3 Pin 5, control connector (dual output)
Return
CN3 Pin 6, control connector
Note:
1. Applying <0.3 V or short between
pins 5(6) and 3 turns the output OFF.
2. Applying >4.5 V or open circuit between
pins 5(6) and 3 turns output ON.
Note:
1. 0.5 V to 3.0 V represents 0% to 100% full load.
Remote Sense
Optional AC Fail
Single Output Only
Output
+
+12 V
CD
CN3 Pin 1 Sense
+
+
Twisted Pair
Supply
LOAD
1K
CL
CN3 Pin 2 Sense
-
Output
-
CN3 Pin 5, control connector
AC Fail
CD
5V
CN3 Pin 6, control connector
Return
Note:
1. CL is 47 µF electrolytic capacitor.
2. CD is 0.1 µF ceramic capacitor.
Parallel Connection with Current Share Option
Single Output Only
Output
Supply 1
AC GOOD
Return
CN3 Pin 7 Current Share
V1
LOAD
Comm
Supply 2
Output
AC FAIL
Return
CN3 Pin 7 Current Share
Sink current = 250 mA
Source current = 7 mA
Note: Current share option includes internal blocking diodes.
Power Good
+5 V
1K
POWER GOOD
CN3 Pin 4, control connector
PG
Sink current = 5 mA
Source current = 1 mA
POWER NOT GOOD
CN3 Pin 6, control connector (single output)
CN3 Pin 5, control connector (dual output)
Return
18-Dec-07
AC-DC
SMM
Application Notes