TI SN74ACT11D

SN54ACT11, SN74ACT11
TRIPLE 3-INPUT POSITIVE-AND GATES
SCAS531A – AUGUST 1995 – REVISED APRIL 1996
D
D
D
SN54ACT11 . . . J OR W PACKAGE
SN74ACT11 . . . D, DB, N, OR PW PACKAGE
(TOP VIEW)
Inputs Are TTL-Voltage Compatible
EPIC  (Enhanced-Performance Implanted
CMOS) 1-µm Process
Package Options Include Plastic
Small-Outline (D), Shrink Small-Outline
(DB), and Thin Shrink Small-Outline (PW)
Packages, Ceramic Chip Carriers (FK) and
Flatpacks (W), and Standard Plastic (N) and
Ceramic (J) DIPS
1A
1B
2A
2B
2C
2Y
GND
1
14
2
13
3
12
4
11
5
10
6
9
7
8
VCC
1C
1Y
3A
3B
3C
3Y
description
The ’ACT11 contain three independent 3-input
AND gates. The devices perform the Boolean
functions Y = A • B • C or Y = A + B + C in positive
logic.
1B
1A
NC
VCC
1C
SN54ACT11 . . . FK PACKAGE
(TOP VIEW)
The SN54ACT11 is characterized for operation
over the full military temperature range of – 55°C
to 125°C. The SN74ACT11 is characterized for
operation from – 40°C to 85°C.
2A
NC
2B
NC
2C
INPUTS
A
B
C
OUTPUT
Y
H
H
H
H
L
X
X
L
X
L
X
L
X
X
L
L
1B
1C
2A
2B
2C
3A
3B
3C
1
5
17
6
16
7
15
8
14
9 10 11 12 13
1Y
NC
3A
NC
3B
NC – No internal connection
logic symbol†
1A
3 2 1 20 19
18
2Y
GND
NC
3Y
3C
FUNCTION TABLE
(each gate)
4
logic diagram, each gate (positive logic)
&
2
12
1Y
1A
1B
1C
2Y
2A
2B
2C
3Y
3A
3B
3C
13
3
6
4
5
8
11
10
1
2
13
12
3
4
5
6
11
10
9
8
1Y
2Y
3Y
9
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and
IEC Publication 617-12.
Pin numbers shown are for the D, DB, J, N, PW, and W packages.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
EPIC is a trademark of Texas Instruments Incorporated.
Copyright  1996, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
SN54ACT11, SN74ACT11
TRIPLE 3-INPUT POSITIVE-AND GATES
SCAS531A – AUGUST 1995 – REVISED APRIL 1996
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 200 mA
Maximum power dissipation at TA = 55°C (in still air) (see Note 2): D package . . . . . . . . . . . . . . . . . . 1.25 W
DB package . . . . . . . . . . . . . . . . . . 0.5 W
N package . . . . . . . . . . . . . . . . . . . 1.1 W
PW package . . . . . . . . . . . . . . . . . . 0.5 W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils,
except for the N package, which has a trace length of zero.
recommended operating conditions (see Note 3)
MIN
MAX
MIN
MAX
4.5
5.5
4.5
5.5
VCC
VIH
Supply voltage
VIL
VI
Low-level input voltage
Input voltage
0
VO
IOH
Output voltage
0
High-level output current
IOL
∆t /∆v
Low-level output current
High-level input voltage
2
0.8
Input transition rise or fall rate
TA
Operating free-air temperature
NOTE 3: Unused inputs must be held high or low to prevent them from floating.
2
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
UNIT
V
V
0.8
V
VCC
VCC
V
– 24
– 24
mA
24
24
mA
VCC
VCC
0
0
V
0
8
0
8
ns / V
– 55
125
– 40
85
°C
SN54ACT11, SN74ACT11
TRIPLE 3-INPUT POSITIVE-AND GATES
SCAS531A – AUGUST 1995 – REVISED APRIL 1996
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
4.5 V
IOH = – 50 µA
VOH
IOH = – 24 mA
IOH = – 50 mA†
IOH = – 75 mA†
TA = 25°C
TYP
MAX
SN54ACT11
MIN
MAX
IOL = 50 mA†
IOL = 75 mA†
MIN
4.49
4.4
5.5 V
5.4
5.49
5.4
5.4
4.5 V
3.86
3.7
3.76
5.5 V
4.86
4.7
4.76
MAX
V
3.85
3.85
4.5 V
0.001
0.1
0.1
5.5 V
0.001
0.1
0.1
0.1
4.5 V
0.36
0.5
0.44
5.5 V
0.36
0.5
0.44
5.5 V
0.1
VI = VCC or GND
VI = VCC or GND,
∆ICC‡
One input at 3.4 V,
Other inputs at GND or VCC
IO = 0
V
1.65
5.5 V
II
ICC
UNIT
4.4
5.5 V
IOL = 24 mA
SN74ACT11
4.4
5.5 V
IOL = 50 µA
VOL
MIN
1.65
5.5 V
±0.1
±1
±1
µA
5.5 V
2
40
20
µA
1.6
1.5
mA
5.5 V
0.6
Ci
VI = VCC or GND
5V
2.6
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
‡ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.
pF
"
switching characteristics over recommended operating free-air temperature range,
0.5 V (unless otherwise noted) (see Figure 1)
VCC = 5 V
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
Any
Y
TA = 25°C
MIN
TYP
MAX
SN54ACT11
SN74ACT11
MIN
MAX
MIN
MAX
1.5
6
9.5
1
10.5
1
10.5
1.5
6
9.5
1
10.5
1
10.5
UNIT
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd
Power dissipation capacitance
POST OFFICE BOX 655303
TEST CONDITIONS
TYP
UNIT
CL = 50 pF, f = 1 MHz
20
pF
• DALLAS, TEXAS 75265
3
SN54ACT11, SN74ACT11
TRIPLE 3-INPUT POSITIVE-AND GATES
SCAS531A – AUGUST 1995 – REVISED APRIL 1996
PARAMETER MEASUREMENT INFORMATION
TEST
S1
tPLH/tPHL
Open
From Output
Under Test
CL = 50 pF
(see Note A)
S1
Open
1.5 V
1.5 V
0V
tPHL
tPLH
2 × VCC
500 Ω
3V
Input
(see Note B)
In-Phase
Output
50% VCC
tPLH
tPHL
500 Ω
Out-of-Phase
Output
LOAD CIRCUIT
50% VCC
VOH
50% VCC
VOL
VOLTAGE WAVEFORMS
NOTES: A. CL includes probe and jig capacitance.
B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr
C. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
4
VOH
50% VCC
VOL
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
v 2.5 ns, tf v 2.5 ns.
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright  1998, Texas Instruments Incorporated