MEANWELL SP

SP-240
240W Single Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC Fan
Built-in fan ON / OFF control
LED indicator for power on
Fixed switching frequency at 90KHz
3 years warranty
SPECIFICATION
MODEL
OUTPUT
SP-240-5
SP-240-7.5
SP-240-12
SP-240-15
SP-240-24
SP-240-30
SP-240-48
DC VOLTAGE
5V
7.5V
12V
15V
24V
30V
48V
RATED CURRENT
45A
32A
20A
16A
10A
8A
5A
CURRENT RANGE
0 ~ 45A
0 ~ 32A
0 ~ 20A
0 ~ 16A
0 ~ 10A
0 ~ 8A
0 ~ 5A
RATED POWER
225W
240W
240W
240W
240W
240W
240W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
4 ~ 6V
2.0%
6 ~ 9V
2.0%
10 ~ 14V
1.0%
12 ~ 18V
1.0%
20 ~ 28V
1.0%
27 ~ 33V
1.0%
41 ~ 56V
1.0%
LINE REGULATION
0.5%
0.5%
0.3%
0.3%
0.2%
0.2%
0.2%
LOAD REGULATION
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
VOLTAGE TOLERANCE Note.3
SETUP, RISE TIME
800ms, 50ms/230VAC
HOLD UP TIME (Typ.)
20ms/230VAC
20ms/115VAC at full load
VOLTAGE RANGE
Note.5 88 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
1500ms, 50ms/115VAC at full load
124 ~ 370VDC
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
79%
83%
INRUSH CURRENT (Typ.)
3.6A/115VAC
25A/115VAC
1.8A/230VAC
40A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
FUNCTION FAN CONTROL
WORKING TEMP.
PF>0.98/115VAC at full load
86%
86%
87%
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
9.4 ~ 10.9V
14.7 ~ 17.5V
19 ~ 22.5V
29.5 ~ 35V
6.3 ~ 7.5V
88%
89%
34.7 ~ 41V
57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
90
5
(5V,7.5V), 85
5
(12V,15V,24V,30V,48V) (TSW1 : detect on heatsink of power transistor)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
RTH2 40 FAN ON, 35 FAN OFF(Typ.)
-20 ~ +70
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
OTHERS
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
MTBF
284K hrs min.
DIMENSION
190*93*50mm (L*W*H)
0.8Kg; 18pcs/15.4Kg/1.04CUFT
PACKING
NOTE
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:SP-240-SPEC 2011-08-23
USSPP--23242005
240W Single Output with PFC Function
Mechanical Specification
Unit:mm
12.5
25
Case No.987A
ssee rr ii eess
4-M4 L=6
20.25
150
159.5
139.5
133
49.5
20
7
6
60.5
41.5
43.5
8
2
44
84.5
9.5
4
3
93
4-SO M3 L=4
5
1
190
Air flow
direction
150
12.5
20.25
25
4-M4 L=6
Terminal Pin No. Assignment
Pin No.
1
2
3
50
14max.
Assignment
AC/L
AC/N
FG
Pin No.
4,5
6,7
Block Diagram
fosc : 90KHz
FAN
ON/OFF
CONTROL
EMI FILTER
&
RECTIFIERS
I/P
PFC
CIRCUIT
FG
O.L.P.
O.V.P.
Static Characteristics
100
80
50
LOAD (%)
LOAD (%)
60
40
20
0
+V
-V
DETECTION
CIRCUIT
PWM & PFC
CONTROL
Derating Curve
FAN
RECTIFIERS
&
FILTER
POWER
SWITCHING
O.T.P.
-20
Assignment
DC OUTPUT -V
DC OUTPUT +V
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
100
300
90
250
80
200
70
150
60
100
50
50
40
25
88
90
95
100
115
135
155
175
195
230
264
INPUT VOLTAGE (VAC) 60Hz
File Name:SP-240-SPEC 2011-08-23