MICREL SY55855VKG

Micrel, Inc.
DUAL CML/PECL/LVPECL-to-LVDS
TRANSLATOR
SuperLite™
SY55855V
SuperLite™
SY55855V
FEATURES
■
■
■
■
■
■
■
■
■
Guaranteed fMAX >750MHz over temperature
1.5Gbps throughput capability
3.0V to 5.7V power supply
Guaranteed <700ps propagation delay over
temperature
Guaranteed <50ps within-device skew over
temperature
LVDS compatible outputs
Fully differential I/O architecture
Wide operating temperature range: –40°C to +85°C
Available in a tiny 10-pin MSOP package
SuperLite™
DESCRIPTION
The SY55855V is a fully differential, CML/PECL/
LVPECL-to-LVDS translator. It achieves LVDS signaling
up to 1.5Gbps, depending on the distance and the
characteristics of the media and noise coupling sources.
LVDS is intended to drive 50Ω impedance transmission
line media such as PCB traces, backplanes, or cables.
SY55855V inputs can be terminated with a single
resistor between the true and the complement pins of a
given input.
The SY55855V is a member of Micrel’s new
SuperLite™ family of high-speed logic devices. This family
features very small packaging, high signal integrity, and
operation at many different supply voltages.
FUNCTIONAL BLOCK DIAGRAM
D0
Q0
/D0
/Q0
D1
Q1
/D1
/Q1
APPLICATIONS
■
■
■
■
High-speed logic
Data communications systems
Wireless communications systems
Telecom systems
SuperLite is a trademark of Micrel, Inc.
M9999-110705
[email protected] or (408) 955-1690
Rev.: D
1
Amendment: /0
Issue Date: November 2005
SuperLite™
SY55855V
Micrel, Inc.
PACKAGE/ORDERING INFORMATION
Ordering Information(1)
D0 1
10 VCC
/D0 2
9 Q0
D1 3
8 /Q0
/D1 4
7 Q1
GND 5
6 /Q1
Part Number
Package
Type
Operating
Range
Package
Marking
Lead
Finish
SY55855VKI
K10-1
Industrial
855V
Sn-Pb
SY55855VKITR(2)
K10-1
Industrial
855V
Sn-Pb
SY55855VKG(3)
K10-1
Industrial
855V with
NiPdAu
Pb-Free bar line indicator Pb-Free
SY55855VKGTR(2, 3)
K10-1
Industrial
855V with
NiPdAu
Pb-Free bar line indicator Pb-Free
10-Pin MSOP (K10-1)
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package recommended for new designs.
PIN DESCRIPTION
Pin Number
Pin Name
Pin Function
1, 2
D0, /D0
CML/PECL/LVPECL Input (Differential). This is one of the inputs. It is converted to
LVDS onto the Q0 and /Q0 outputs.
3, 4
D1, /D1
CML/PECL/LVPECL Input (Differential). This is the other input. It is converted to
LVDS onto the Q1 and /Q1 outputs.
5
GND
6, 7
/Q1, Q1
LVDS Output (Differential). This is the other LVDS output. It buffers the CML input
that appears at D1, /D1.
8, 9
/Q0, Q0
LVDS Output (Differential). This is one LVDS output. It buffers the CML input that
appears at D0, /D0.
10
VCC
Ground.
VCC
TRUTH TABLE
D0
D1
Q0
/Q0
Q1
/Q1
0
0
0
1
0
1
0
1
0
1
1
0
1
0
1
0
0
1
1
1
1
0
1
0
M9999-110705
[email protected] or (408) 955-1690
2
SuperLite™
SY55855V
Micrel, Inc.
FUNCTIONAL DESCRIPTION
unconnected. For VCC ≤ 3.0V, connect the complement input
to VCC and leave the true input unconnected. To make an
input static logic one, connect the true input to VCC, leave
the complement input unconnected. These are the only two
safe ways to cause inputs to be at a static value. In particular,
no input pin should be directly connected to ground. All NC
(no connect) pins should be unconnected.
Establishing Static Logic Inputs
The true pin of an input pair is internally biased to ground
through a 75kΩ resistor. The complement pin of an input
pair is internally biased halfway between VCC and ground
by a voltage divider consisting of two 75kΩ resistors. In this
way, unconnected inputs appear as logic zeros. To keep an
input at static logic zero at VCC > 3.0V, leave both inputs
VCC
X
NC
X
NC
/X
NC
/X
VCC > 3.0V
Figure 1. Hard Wiring a Logic “1” (1)
Note 1.
X is either D0 or D1 input. /X is either /D0 or /D1 input.
NC
X
VCC
/X
VCC ≤ 3.0V
Figure 2. Hard Wiring a Logic “0” (1)
Note 1.
M9999-110705
[email protected] or (408) 955-1690
3
X is either D0 or D1 input. /X is either /D0 or /D1 input.
SuperLite™
SY55855V
Micrel, Inc.
LVDS OUTPUTS
LVDS stands for Low Voltage Differential Swing. LVDS
specifies a small swing of 350mV typical, on a nominal
1.25V common mode above ground. The common mode
voltage has tight limits to permit large variations in ground
between an LVDS driver and receiver. Also, change in
common mode voltage, as a function of data input, is also
kept tight, to keep EMI low.
49.9Ω, ±1%
49.9Ω, ±1%
50Ω
50Ω
vOD
vOH, vOL
vOCM,
∆vOCM
GND
100Ω
±1%
Figure 4. LVDS Common Mode Measurement
vOH, vOL
50Ω
50Ω
GND
Figure 3. LVDS Differential Measurement
M9999-110705
[email protected] or (408) 955-1690
100Ω
Figure 5. LVDS Output Termination
4
SuperLite™
SY55855V
Micrel, Inc.
ABSOLUTE MAXIMUM RATINGS(1)
Symbol
Rating
VCC
Power Supply Voltage
VIN
Input Voltage
IOUT
LVDS Output Current
TA
Operating Temperature Range
TLEAD
Lead Temperature (soldering, 20sec.)
Tstore
Storage Temperature Range
Note 1.
Value
Unit
–0.5 to +6.0
V
–0.5 to VCC +0.5
V
±10%
mA
–40 to +85
°C
260
°C
–65 to +150
°C
Permanent device damage may occur if absolute maximum ratings are exceeded. This is a stress rating only and functional operation is not
implied at conditions other than those detailed in the operational sections of this data sheet. Exposure to absolute maximum ratlng conditions
for extended periods may affect device reliability.
DC ELECTRICAL CHARACTERISTICS
VCC = 3.0V to 5.7V; GND = 0V; TA = –40°C to +85°C(2)
TA = –40°C
Symbol
Parameter
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Typ.
Max.
Min.
Max.
Unit
V
VCC
Power Supply Voltage
3.0
5.7
3.0
—
5.7
3.0
5.7
ICC
Power Supply Current
3.6V <VCC <5.7V
VCC ≤3.6V
—
—
80
50
—
—
—
30
80
50
—
—
80
50
mA
CML DC ELECTRICAL CHARACTERISTICS
VCC = 3.0V to 5.7V; GND = 0V; TA = –40°C to +85°C(2)
Symbol
Parameter
Min.
Typ.
Max.
Unit
Condition
VID
Differential Input Voltage
100
—
—
mV
VIH
Input HIGH Voltage
1.6
—
VCC
V
VIL
Input LOW Voltage
1.5
—
VCC – 0.1
V
Min.
Typ.
Max.
Unit
Condition
250
—
450
mV
100Ω Termination
1.125
—
1.375
V
LVDS DC ELECTRICAL CHARACTERISTICS
VCC = 3.0V to 5.7V; GND = 0V; TA = –40°C to +85°C(2)
Symbol
Parameter
Voltage(4)
VOD
Differential Output
VOCM
Output Common Mode
Voltage(3)
∆VOCM
Change in Common Mode
Voltage(3)
–50
—
+50
mV
VOH
Output HIGH Voltage(4), (5)
—
—
1.474
V
IOH = –4.0mA
VOL
Voltage(4), (5)
0.925
—
—
V
IOL = 4.0mA
Output LOW
Note 2.
Equilibrium temperature.
Note 3.
Measured as per Figure 4.
Note 4.
Measured as per Figure 3.
Note 5.
Do not short output to GND.
M9999-110705
[email protected] or (408) 955-1690
5
SuperLite™
SY55855V
Micrel, Inc.
AC ELECTRICAL CHARACTERISTICS(1)
VCC = 3.0V to 5.7V; GND = 0V; TA = –40°C to +85°C(2)
Symbol
Parameter
Min.
Typ.
Max.
Unit
fMAX
Maximum Operating Frequency
750
—
—
MHz
tPLH
tPHL
Propagation Delay
D0 to Q0, D1 to Q1
300
—
700
ps
tSKEW
Within-Device Skew(3)
Part-to-Part Skew (Diff.)
—
—
—
—
50
250
ps
tr
tf
LVDS Output Differential
Rise/Fall Times (20% to 80%)
100
—
300
ps
Note 1.
Specification for packaged product only.
Note 2.
Equilibrium temperature.
Note 3.
Worst case difference between Q0 and Q1 from either D0 or D1, when both outputs have the same transition.
M9999-110705
[email protected] or (408) 955-1690
6
Condition
SuperLite™
SY55855V
Micrel, Inc.
EYE DIAGRAMS(1)
Note 1.
622Mbps
3.3V LVPECL-to-LVDS
1.25Gbps
3.3V LVPECL-to-LVDS
1.5Gbps
3.3V LVPECL-to-LVDS
622Mbps
3.3V CML-to-LVDS
1.25Gbps
3.3V CML-to-LVDS
1.5Gbps
3.3V CML-to-LVDS
223–1 pattern.
M9999-110705
[email protected] or (408) 955-1690
7
SuperLite™
SY55855V
Micrel, Inc.
10-PIN MSOP (K10-1)
Rev. 00
MICREL, INC.
TEL
2180 FORTUNE DRIVE SAN JOSE, CA 95131
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2005 Micrel, Incorporated.
M9999-110705
[email protected] or (408) 955-1690
8