SY89465U Precision LVDS 1:10 Fanout with 2:1 Runt Pulse Eliminator MUX and Internal Termination General Description The SY89465U is a low-jitter, 1:10 LVDS fanout buffer with a 2:1 differential input multiplexer (MUX) optimized for redundant source switchover applications. Unlike standard multiplexers, the SY89465Us 2:1 Runt Pulse Eliminator (RPE) MUX prevents any short cycles or “runt” pulses during switchover. In addition, a unique Fail-Safe Input (FSI) protection prevents metastable conditions when the selected input clock fails to a DC voltage (voltage between the pins of the differential input drops below 100mV). The differential input includes Micrel’s, 3-pin internal termination architecture that allows customers to interface to any differential signal (AC- or DCcoupled) as small as 100mV (200mVPP) without any level shifting or termination resistor networks in the signal path. The outputs are LVDS-compatible with fast rise/fall times guaranteed to be less than 220ps. The SY89465U operates from a 2.5V ±5% supply and is guaranteed over the full industrial temperature range of –40°C to +85°C. The SY89465U is part of Micrel’s high-speed, Precision Edge® product line. All support documentation can be found on Micrel’s web site at: www.micrel.com. Precision Edge® Features • Selects between two sources, and provides 10 precision LVDS copies • Guaranteed AC performance over temperature and supply voltage: – Wide operating frequency: 1kHz to >1.5GHz – <1200ps In-to-Out tpd – <220ps tr/tf • Unique, patent-pending input isolation design minimizes adjacent channel crosstalk • Fail-Safe Input prevents oscillations • Ultra-low jitter design: – 183 fsRMS phase jitter (typical) – <0.7psRMS MUX crosstalk-induced jitter • Unique patented input termination and VT pin accepts DC- and AC-coupled inputs (CML, PECL, LVDS) • 325mV LVDS output swing • 2.5V ±5% supply voltage • −40°C to +85°C industrial temperature range • Output enable • Available in 44-pin (7mm x 7mm) QFN package Applications • Redundant clock switchover • Fail-safe clock protection Markets • • • • LAN/WAN Enterprise servers ATE Test and measurement Precision Edge is a registered trademark of Micrel, Inc. Micrel Inc. • 2180 Fortune Drive • San Jose, CA 95131 • USA • tel +1 (408) 944-0800 • fax + 1 (408) 474-1000 • http://www.micrel.com August 2010 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U Typical Application Simplified Example Illustrating Runt Pulse Eliminator (RPE) when Primary Clock Fails Ordering Information Part Number Package Type Operating Range Package Marking Lead Finish SY89465UMY QFN-44 Industrial SY89465U with Pb-Free bar-line Indicator Matte-Sn Pb-Free SY89465UMYTR(2) QFN-44 Industrial SY89465U with Pb-Free bar-line Indicator Matte-Sn Pb-Free Notes: 1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only. 2. Tape and Reel. August 2010 2 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U Pin Configuration 44-Pin QFN Pin Description Pin Number Pin Name 2, 5, 7, 10 IN0, /IN0 IN1, /IN1 Differential Inputs: These input pairs are the differential signal inputs to the device. These inputs accept AC- or DC-coupled signals as small as 100mV (200mVpp). Each pin of a pair internally terminates to a VT pin through 50Ω. Please refer to the “Input Interface Applications” section for more details. VREF-AC0 VREF-AC1 Reference Voltage: These outputs bias to VCC –1.2V. They are used for AC-coupling inputs IN and /IN. Connect VREF-AC directly to the corresponding VT pin. Bypass with 0.01µF low ESR capacitor to VCC. Due to the limited drive capability, the VREF-AC pin is only intended to drive its respective VT pin. Maximum sink/source current is ±1.5mA. Please refer to the “Input Interface Applications” section for more details. 3, 8 VT0, VT1 Input Termination Center-Tap: Each side of the differential input pair terminates to a VT pin. The VT0 and VT1 pins provide a center-tap to a termination network for maximum interface flexibility. Please refer to the “Input Interface Applications” section for more details. 13, 15, 22, 23 28, 33, 34, 41, 43, 44 VCC Positive Power Supply: Bypass with 0.1µF||0.01µF low-ESR capacitors as close to the VCC pins as possible. 39, 40 37, 38 35, 36 31, 32 29, 30 26, 27 24, 25 20, 21 18, 19 16, 17 /Q0, Q0 /Q1, Q1 /Q2, Q2 /Q3, Q3 /Q4, Q4 /Q5, Q5 /Q6, Q6 /Q7, Q7 /Q8, Q8 /Q9, Q9 Differential Outputs: These differential LVDS outputs are a logic function of the IN0, IN1, and SEL inputs. Please refer to the “Truth Table” below for details. 4, 9 August 2010 Pin Function 3 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U Pin Description (Continued) Pin Number Pin Name 42 SEL 1, 11, 6 GND, Exposed Pad 12 Pin Function This single-ended TTL/CMOS-compatible input selects the inputs to the multiplexer. Note that this input is internally connected to a 25kΩ pull-up resistor and will default to logic HIGH state if left open. VTH = VCC/2. Ground: Ground and exposed pad must be connected to the same ground plane. CAP Power-on-Reset (POR) initialization capacitor. When using the multiplexer with RPE capability, this pin is tied to a capacitor to VCC. The purpose is to ensure the internal RPE logic starts up in a known state. See “Power-On Reset (POR) Description” section for more details regarding capacitor selection. If this pin is tied directly to VCC, the RPE function will be disabled and the multiplexer will function as a normal multiplexer. The CAP pin should never be left open or tied directly to GND. EN Single-Ended Input: This TTL/CMOS input disables and enables the Q0-Q9 outputs. It is internally connected to a 25kΩ pull-up resistor and will default to a logic HIGH state if left open. When disabled, CLK output goes LOW and /CLK goes HIGH. EN being synchronous, outputs will be enabled/disabled when they are in LOW state. Thus, a runt pulse is avoided if the device is enabled/disabled by an asynchronous control. VTH = VCC/2. 14 Truth Table Inputs Outputs IN0 /IN0 IN1 /IN1 SEL Q /Q 0 1 X X 0 0 1 1 0 X X 0 1 0 X X 0 1 1 0 1 X X 1 0 1 1 0 August 2010 4 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U Absolute Maximum Ratings(1) Operating Ratings(2) Supply Voltage (VCC) ..........................–0.5V to +4.0V Input Voltage (VIN) ..................................–0.5V to VCC Input Current (IIN) ........................................................ Source/Sink Current on IN, /IN ................ ±50mA Source/Sink Current on VT ..................... ±100mA VREF-AC Current Source/Sink Current on VREF-AC.................. ±2mA Lead Temperature (soldering, 20 sec.) ..........+260°C Storage Temperature (Ts)..................–65°C to 150°C Supply Voltage (VCC).................. +2.375V to +2.625V Ambient Temperature (TA)................ –40°C to +85°C Package Thermal Resistance(3) QFN (θ JA) Still-Air .................................................. 24.4°C/W QFN (ψ JB) Junction-to-Board ................................... 8.1°C/W DC Electrical Characteristics(4) TA = –40°C to +85°C, unless otherwise stated. Symbol Parameter VCC Power Supply Condition Min. Typ. Max. Units 2.375 2.5 2.625 V ICC Power Supply Current 250 325 mA RIN Input Resistance (IN-to-VT) No load, max VCC 45 50 55 Ω RDIFF_IN Differential Input Resistance (IN-to-/IN) 90 100 110 Ω VIH Input High Voltage (IN, /IN) 1.2 VCC V VIL Input Low Voltage (IN, /IN) 0 VIH – 0.1 V 2.5 V VIN Input Voltage Swing (IN, /IN) See Figure 1a (Note 5) 0.1 VDIFF_IN Differential Input Voltage Swing |IN-/IN| See Figure 1b 0.2 VIN_FSI Input Voltage Threshold that Triggers FSI VT_IN IN-to-VT (IN, /IN) VREF-AC Output Reference Voltage V 30 VCC – 1.3 VCC – 1.2 100 mV 1.28 V VCC – 1.1 V Notes: 1. Permanent device damage may occur if absolute maximum ratings are exceeded. This is a stress rating only and functional operation is not implied at conditions other than those detailed in the operational sections of this data sheet. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. 2. The data sheet limits are not guaranteed if the device is operated beyond the operating ratings. 3. Package thermal resistance assumes exposed pad is soldered (or equivalent) to the devices most negative potential on the PCB. θJA and ψJB values are determined for a 4-layer board in still air unless otherwise stated. 4. The circuit is designed to meet the DC specifications shown in the above table after thermal equilibrium has been established. 5. VIN (max) is specified when VT is floating. August 2010 5 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U LVDS Outputs DC Electrical Characteristics(6) VCC = 2.5V ±5%; RL = 100Ω across output pair or equivalent; TA = –40°C to + 85°C, unless otherwise stated. Symbol Parameter Condition Min. Typ. Max. Units VOCM Output Common Mode Voltage 1.125 1.275 V ΔVOCM Change in VOCM between complementing output states –50 +50 mV VOUT Output Voltage Swing See Figure 1a. 250 325 mV VDIFF-OUT Differential Output Voltage Swing See Figure 1b. 500 650 mV Min. Typ. LVTTL/CMOS DC Electrical Characteristics(6) VCC = 2.5V ±5%; TA = –40°C to + 85°C, unless otherwise stated. Symbol Parameter Condition VIH Input HIGH Voltage VIL Input LOW Voltage IIH Input HIGH Current -125 IIL Input LOW Current -300 Max. Units 0.8 V 30 µA 2.0 V µA Note: 6. The circuit is designed to meet the DC specifications shown in the above table after thermal equilibrium has been established. August 2010 6 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U AC Electrical Characteristics(7) VCC = 2.5V ±5%; RL = 100Ω across the output pair; TA = –40°C to + 85°C, unless otherwise stated. Symbol Parameter Condition fMAX Maximum Operating Frequency VOUT ≥ 200mV, Clock Min. Typ. 1.5 2.0 Max. Units GHz Differential Propagation Delay In-to-Q tpd tPD Tempco In-to-Q 100mV < VIN ≤ 200mV (8) 550 800 1200 200mV < VIN ≤ 800mV (8) 500 700 1100 SEL-to-Q RPE enabled, see Timing Diagram SEL-to-Q RPE disabled (VSEL = VCC/2) 600 Differential Propagation Delay Temperature Coefficient ps 17 cycles 1200 ps fs/oC 500 tS EN Set-up Time EN-to-CLK Note 9 0 ps tH EN Hold Time CLK-to-EN Note 9 650 ps tSKEW tJITTER tr, tf Output-to-Output Skew Note 10 Part-to-Part Skew Note 11 RMS Phase Jitter 5 25 300 Output: 622MHz 183 Integration Range: 12kHz − 20MHz Crosstalk-Induced Jitter Note 12 Output Rise/Fall Time (20% to 80%) At full output swing. 70 120 ps fs 0.7 psRMS 220 ps Notes: 7. High-frequency AC-parameters are guaranteed by design and characterization. 8. Propagation delay is measured with input tr, tf ≤ 300ps (20% to 80%) and VIL ≥ 800mV. The propagation delay is function of the rise and fall times at IN. See “Typical Operating Characteristics” for details. 9. Set-up and hold times apply to synchronous applications that intend to enable/disable before the next clock cycle. For asynchronous applications, set-up and hold do not apply. 10. Output-to-Output skew is measured between two different outputs under identical transitions. 11. Part-to-Part skew is defined for two parts with identical power supply voltages at the same temperature and with no skew of the edges at the respective inputs. 12. Crosstalk is measured at the output while applying two similar differential clock frequencies that are asynchronous with respect to each other at the inputs. August 2010 7 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U Phase Noise Graph August 2010 8 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U RPE and FSI Functionality The basic operation of the RPE MUX and FSI functionality is described with the following four case descriptions. All descriptions are related to the true inputs and outputs. The primary (or selected) clock is called CLK1; the secondary (or alternate) clock is called CLK2. Due to the totally asynchronous relation of the IN and SEL signals and an additional internal protection against metastability, the number of pulses required for the operations described in cases 1-4 can vary within certain limits. Refer to “Timing Diagrams” section for detailed information. Case #1: Two Normal Clocks and RPE Enabled In this case, the frequency difference between the two running clocks, IN0 and IN1, must not be greater than 1.5:1. For example, if the IN0 clock is 500MHz, the IN1 clock must be within the range of 334MHz to 750MHz. If the SEL input changes state to select the alternate clock, the switchover from CLK1 to CLK2 will occur in three stages. Functional Description RPE MUX and Fail-Safe Input The SY89465U is optimized for clock switchover applications where switching from one clock to another clock without runt pulses (short cycles) is required. It features two unique circuits: Runt-Pulse Eliminator (RPE) Circuit The RPE MUX provides a “glitchless” switchover between two clocks and prevents any runt pulses from occurring during the switchover transition. The design of both clock inputs is identical (i.e., the switchover sequence and protection is symmetrical for both input pairs, IN0 or IN1. Thus, either input pair may be defined as the primary input). If not required, the RPE function can be permanently disabled to allow the switchover between inputs to occur immediately. If the CAP pin is tied directly to VCC, the RPE function will be disabled and the multiplexer will function as a normal multiplexer. Fail-Safe Input (FSI) Circuit The FSI function provides protection against a selected input pair that drops below the minimum amplitude requirement. If the selected input pair drops sufficiently below the 100mV minimum singleended input amplitude limit (VIN), or 200mV differentially (VDIFF_IN), the output will latch to the last valid clock state. • Stage 1: The output will continue to follow CLK1 for a limited number of pulses. • Stage 2: The output will remain LOW for a limited number of pulses of CLK2. • Stage 3: The output follows CLK2. Timing Diagram 1 August 2010 9 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U • Stage 1: The output will remain HIGH for a limited number of pulses of CLK2. • Stage 2: The output will switch to LOW and then remain LOW for a limited number of falling edges of CLK2. • Stage 3: The output will follow CLK2. Case #2: Input Clock Failure: Switching from a selected clock stuck HIGH to a valid clock (RPE enabled). If CLK1 fails HIGH before the RPE MUX selects CLK2 (using the SEL pin), the switchover will occur in three stages. Timing Diagram 2 Note: Output shows extended clock cycle during switchover. Pulse width for both high and low of this cycle will always be greater than 50% of the CLK2 period. August 2010 10 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U • Stage 1: The output will remain LOW for a limited number of falling edges of CLK2. • Stage 2: The output will follow CLK2. Case #3: Input Clock Failure: Switching from a selected clock stuck Low to a valid clock (RPEenabled). If CLK1 fails LOW before the RPE MUX selects CLK2 (using the SEL pin), the switchover will occur in two stages. Timing Diagram 3 August 2010 11 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U Case #4: Input Clock Failure: Switching from the selected clock input stuck in an undetermined state to a valid clock input (RPE-enabled). If CLK1 fails to an undetermined state (e.g., amplitude falls below the 100mV (VIN) minimum single-ended input limit, or 200mV differentially) before the RPE MUX selects CLK2 (using the SEL pin), the switchover to the valid clock CLK2 will occur either following Case #2 or Case #3, depending upon the last valid state at the CLK1. If the selected input clock fails to a floating, static, or extremely low signal swing, including 0mV, the FSI function will eliminate any metastable condition and guarantee a stable output signal. No ringing and no undetermined state will occur at the output under these conditions. Please note that the FSI function will not prevent duty cycle distortions or runt pulses in case of a slowly deteriorating (but still toggling) input signal. Due to the FSI function, the propagation delay will depend upon rise and fall time of the input signal and on its amplitude. Refer to “Typical Operating Characteristics” for detailed information. Timing Diagram 4 August 2010 12 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U Enable Output(s): 1. EN toggles from Low-to-High. 2. Output(s) follow the selected clock after next HIGH-to-LOW transition of the selected input. See “Timing Diagram 5.” Enable Output (EN) Description The enable function is synchronous so that the outputs will be enabled/disabled when they are already in the LOW state. This avoids any chance of generating a runt pulse when the device is enabled/disabled as can happen with asynchronous control. Disable Output(s): 1. EN toggles from High-to-Low 2. Output(s) follow the selected Clock input 3. Output (CLK) goes to a logic LOW level (/CLK goes to a logic HIGH), after next Highto-Low transition of the selected input. See Timing Diagram 5. Timing Diagram 5 August 2010 13 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U The following formula describes this relationship: Power-On Reset (POR) Description The SY89465U includes an internal power-on reset (POR) function to ensure that the RPE logic startsup in a known logic state once the power-supply voltage is stable. An external capacitor connected between VCC and the CAP pin (pin 12) controls the delay for the power-on reset function. C(μF) ≥ As an example, if the time required for the system power supply to power up past 2.3V is 12ms, then the required capacitor value on pin 12 would be: The required capacitor value calculation is based upon the time the system power supply needs to power up to a minimum of 2.3V. The time constant for the internal power-on-reset must be greater than the time required for the power supply to ramp up to a minimum of 2.3V. August 2010 t dPS (ms) 12(ms/μF) C(μF) ≥ 12ms 12(ms/μF) C(µF) ≥ 1µF 14 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U Typical Operating Characteristics VCC = 2.5V, GND = 0V, VIN ≥ 400mV, tr / tf ≤ 300ps, RL = 50Ω to VCC–2V; TA = 25°C, unless otherwise stated. August 2010 15 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U Functional Characteristics VCC = 2.5V, GND = 0V, VIN ≥ 400mVpk, tr/tf ≤ 300ps, RL = 100Ω across output pair; TA = 25°C, unless otherwise stated. August 2010 16 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U Single-Ended and Differential Swings Figure 1b. Differential Voltage Swing Figure 1a. Single-Ended Voltage Swing Input and Output Stages Figure 2b. Simplified Differential Output Stage Figure 2a. Simplified Differential Input Stage August 2010 17 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U Input Interface Applications Option: may connect VT to VCC Figure 3a. LVPECL Interface (DC-Coupled) Figure 3b. LVPECL Interface (AC-Coupled) Figure 3d. CML Interface (AC-Coupled) Figure 3e. LVDS Interface (DC-Coupled) August 2010 18 Figure 3c. CML Interface (DC-Coupled) M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U variations in ground between an LVDS driver and receiver. Also, change in common mode voltage, as a function of data input, is kept to a minimum, to keep EMI low. LVDS Output Interface Applications LVDS specifies a small swing of 325mV typical, on a nominal 1.20V common mode above ground. The common mode voltage has tight limits to permit large Figure 4a. LVDS Differential Measurement Figure 4b. LVDS Common Mode Measurement Related Product and Support Documentation Part Number Function Data Sheet Link SY89464U Precision LVPECL Runt Pulse Eliminator 2 :1 MUX with 1:10 Fanout Buffer and Internal Termination www.micrel.com/product-info/products/sy89464u.shtml HBW Solutions New Products and Applications www.micrel.com/product-info/products/solutions.shtml August 2010 19 M9999-080510-C [email protected] or (408) 955-1690 Micrel, Inc. SY89465U Package Information Packages Notes: 1. Package meets Level 2 Moisture Sensitivity Classification. 2. All parts are dry-packed before shipment. 3. Exposed pad must be soldered to a ground for proper thermal management. 44-Pin QFN MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA TEL +1 (408) 944-0800 FAX +1 (408) 474-1000 WEB http://www.micrel.com The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or systems is a Purchaser’s own risk and Purchaser agrees to fully indemnify Micrel for any damages resulting from such use or sale. © 2005 Micrel, Inc. August 2010 20 M9999-080510-C [email protected] or (408) 955-1690