VECTRON TFS162A

Filename: tfs 162a.doc
VI TELEFILTER
Version 1.1
07.04.2005
Filter specification
TFS 162A
1/5
Measurement condition
Ambient temperature:
23 °C
Input power level:
0 dBm
Terminating impedance *
Input
650 Ω || -1.3 pF
Output
650 Ω || -1.3 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 162A is the maximum attenuation in the pass band. The maximum attenuation in the pass
band is defined as the insertion loss ae. The nominal frequency fN is fixed at 162,2 MHz without any tolerance or limit. The values of relative attenuation
arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the
production tolerance scheme.
Data
typ. value
Insertion loss
(reference level)
ae
Nominal frequency
fN
Centre frequency
fC
Usable signal bandwidth
Bandwidth
3
+
910
162,2
dB
max.
5
dB
162,2
MHz
fN ± 10
kHz
MHz
-
min.
BW
dB
Relative attenuation
fN
3,4
tolerance / limit
OTR
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
kHz
66
dB
-
arel
kHz
Operating temperature range
100
TCf **
min.
60
-
- 20 °C ... + 70°C
-
- 30 °C ... + 85°C
25
°C
-0,036
ppm/K
dB
2
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 162a.doc
Version 1.1
VI TELEFILTER
07.04.2005
Filter specification
TFS 162A
2/5
Filter characteristic
-2
0
-10
-3
-20
-30
magnitude in dB
magnitude in dB
-4
-5
-6
-40
-50
-60
-70
-80
-7
-90
-8
162.1
162.12 162.14 162.16 162.18
162.2
162.22 162.24 162.26 162.28
-100
162.3
161.2 161.4 161.6 161.8
frequency in MHz
162
162.2 162.4 162.6 162.8
163
163.2
frequency in MHz
Construction and pin connection
(All dimensions in mm)
+0,2
TFS 162A
●
T14
1
1,4 +/-0,2
7,1 - 0,1
0,2
9,1 +-0,1
Date cod e
5,08
1
2,54
8
Ground
Input
Ground
Ground
Ground
Ground
Output
Ground
Ground
Ground
Date code:
T
U
V
...
Year + week
2005
2006
2007
3
R 0 ,2
0,8
1
2
3
4
5
6
7
8
9
10
6
1
50 Ω Test circuit
2
L1
7
L2
SAW
C1
C2
1, 3, 4, 5, 6, 8, 9, 10
Stability characteristics
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 162a.doc
Version 1.1
VI TELEFILTER
07.04.2005
Filter specification
TFS 162A
3/5
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
2000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,10
F
: 7,50 ± 0,10
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
: 1,50 +0,1/-0
Ao
: 7,60 ± 0,10
Bo
: 9,60 ± 0,10
Ct
: 13,5
t
P1
Date Code
P2
W
G
Ct
Bo
F
G
E
Do
Po
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4
W2(max) : 22,4
N(min)
: 50
C
: 13,0
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 162a.doc
Version 1.1
VI TELEFILTER
07.04.2005
Filter specification
TFS 162A
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 162a.doc
VI TELEFILTER
Version 1.1
Filter specification
07.04.2005
TFS 162A
5/5
History
Version
Reason of Changes
Name
Date
1.0
Generation of development specification
Strehl
10.02.2005
1.1
Generation of filter specification, added typical values and filter characteristic
Martens
07.04.2005
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.