Filename: tfs 162a.doc VI TELEFILTER Version 1.1 07.04.2005 Filter specification TFS 162A 1/5 Measurement condition Ambient temperature: 23 °C Input power level: 0 dBm Terminating impedance * Input 650 Ω || -1.3 pF Output 650 Ω || -1.3 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 162A is the maximum attenuation in the pass band. The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 162,2 MHz without any tolerance or limit. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss (reference level) ae Nominal frequency fN Centre frequency fC Usable signal bandwidth Bandwidth 3 + 910 162,2 dB max. 5 dB 162,2 MHz fN ± 10 kHz MHz - min. BW dB Relative attenuation fN 3,4 tolerance / limit OTR Storage temperature range Frequency inversion temperature Temperature coefficient of frequency kHz 66 dB - arel kHz Operating temperature range 100 TCf ** min. 60 - - 20 °C ... + 70°C - - 30 °C ... + 85°C 25 °C -0,036 ppm/K dB 2 *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 162a.doc Version 1.1 VI TELEFILTER 07.04.2005 Filter specification TFS 162A 2/5 Filter characteristic -2 0 -10 -3 -20 -30 magnitude in dB magnitude in dB -4 -5 -6 -40 -50 -60 -70 -80 -7 -90 -8 162.1 162.12 162.14 162.16 162.18 162.2 162.22 162.24 162.26 162.28 -100 162.3 161.2 161.4 161.6 161.8 frequency in MHz 162 162.2 162.4 162.6 162.8 163 163.2 frequency in MHz Construction and pin connection (All dimensions in mm) +0,2 TFS 162A ● T14 1 1,4 +/-0,2 7,1 - 0,1 0,2 9,1 +-0,1 Date cod e 5,08 1 2,54 8 Ground Input Ground Ground Ground Ground Output Ground Ground Ground Date code: T U V ... Year + week 2005 2006 2007 3 R 0 ,2 0,8 1 2 3 4 5 6 7 8 9 10 6 1 50 Ω Test circuit 2 L1 7 L2 SAW C1 C2 1, 3, 4, 5, 6, 8, 9, 10 Stability characteristics Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 162a.doc Version 1.1 VI TELEFILTER 07.04.2005 Filter specification TFS 162A 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 2000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,10 F : 7,50 ± 0,10 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 12,00 ± 0,1 D1(min) : 1,50 +0,1/-0 Ao : 7,60 ± 0,10 Bo : 9,60 ± 0,10 Ct : 13,5 t P1 Date Code P2 W G Ct Bo F G E Do Po Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 W2(max) : 22,4 N(min) : 50 C : 13,0 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 162a.doc Version 1.1 VI TELEFILTER 07.04.2005 Filter specification TFS 162A 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 162a.doc VI TELEFILTER Version 1.1 Filter specification 07.04.2005 TFS 162A 5/5 History Version Reason of Changes Name Date 1.0 Generation of development specification Strehl 10.02.2005 1.1 Generation of filter specification, added typical values and filter characteristic Martens 07.04.2005 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.