TRUMPOWER TMC60-S48

37.5-64 WATT MEDICAL & ITE SWITCHING POWER SUPPLIES
TRUMPower
DESCRIPTION
The TMC60 series of compact, open PCB constructed, AC-DC
switching power supplies are capable of delivering 37.5-64
watts of continuous output power at convection cooling. They
operate at 90-264 VAC input voltage without the need of
voltage selection, and are suited for medical, information
technology and industrial applications. Approval to both EN
60601-1 and EN 60950-1 safety standards improves design-in
time and reduces end equipment compliance costs.
TMC60 SERIES
FEATURES
z
z
z
z
z
z
z
Medical and ITE approvals
Compact size 2” x 4” x 1.18”
Single, dual and triple outputs
F u l l r a n g e i n p u t 9 0 - 2 6 4 VA C
Low earth leakage current
Level B emissions
RoHS compliant
SAFETY STANDARD APPROVALS
UL 60601-1
CSA C22.2 No. 601.1
INPUT SPECIFICATIONS
Input voltage:
Input frequency:
Input current:
Earth leakage current:
90-264 VAC
47-63 Hz
1.3 A (rms) for 100 VAC
0.7 A (rms) for 240 VAC
150 µA max. @ 264 VAC, 60 Hz
TÜV EN60601-1
GENERAL SPECIFICATIONS
Switching frequency:
Efficiency:
Ripple and noise:
Overvoltage protection:
Overcurrent protection:
Temperature coefficient:
Transient response:
See rating chart
See rating chart
2% peak to peak on 5.0 V model, 1% peak
to peak on other models.
Provided on output #1 only;
set at 112-132% of its nominal output
voltage
All outputs protected to short circuit
conditions
o
All outputs ±0.04% / C maximum
Maximum excursion of 4% or better on all
models, recovering to 1% of final value
within 500 µs after a 25% step load
change
ENVIRONMENTAL SPECIFICATIONS
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
o
80-88% typical except TMC60-T31-3 and
TMC60-T31-5 at 75% typical
OUTPUT SPECIFICATIONS
Output voltage/current:
Maximum output power:
62±5 KHz
o
-10 C to +70 C
o
o
-40 C to +85 C
5% to 95% non-condensing
o
Derate from 100% at +50 C linearly to
o
50% at +70 C
Hold-up time:
12 msec minimum at 110 VAC
Line regulation:
±0.5% maximum at full load
Inrush current:
30 A @ 115 VAC, or 60 A @ 230 VAC,
Withstand voltage:
4000 VAC from input to output
o
at 25 C cold start
1500 VAC from input to ground
500 VAC from output to ground
MTBF:
o
400,000 hours at full load at 25 C ambient,
calculated per MIL-HDBK-217F
EMC Performance
EN55011 / EN55022:
Class B conducted, class B radiated
FCC:
Class B conducted, class B radiated
VCCI:
Class B conducted, class B radiated
EN61000-3-2:
Harmonic distortion, class A and D
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ±8 KV air and ±6 KV contact
EN61000-4-3:
Radiated immunity, 3 V/m
EN61000-4-4:
Fast transient/burst, ±2 KV
EN61000-4-5:
Surge, ±1 KV diff., ±2 KV com.
EN61000-4-6:
Conducted immunity, 3 Vrms
EN61000-4-8:
Magnetic field immunity, 3 A/m
EN61000-4-11:
Voltage dips,
30% reduction for 500 ms
60% reduction for 100 ms
>95% reduction for 10 ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com
UNIVERSAL INPUT
TMC60 MEDICAL & ITE SERIES
OUTPUT VOLTAGE/CURRENT RATING CHART
Output #1
P/N
Vnom
TMC60-S05
5V
TMC60-S12
12 V
TMC60-S15
15 V
TMC60-S24
24 V
TMC60-S48
48 V
TMC60-D23
+5 V
TMC60-D25
+5 V
TMC60-T31
+5 V
TMC60-T31-3 +3.3 V
TMC60-T31-5
+5 V
TMC60-T32
+5 V
TMC60-T39
+5 V
NOTES: 1.
2.
3.
4.
Output #2
Min.-Max.Current Min.-Max.Current
Tol.
at convection
at forced air (2)
0-11 A
0-5 A
0-4.3 A
0-2.7 A
0-1.35 A
0.5-6 A
0.5-6 A
0.5-6 A
0.8-6 A
0.5-6 A
0.5-6 A
0.5-6 A
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
0.5-8 A
0.5-8 A
0.5-8 A
0.5-8 A
0.5-8 A
0.5-8 A
0.5-8 A
2%
2%
2%
2%
2%
3%
3%
3%
3%
3%
3%
3%
Maximum
Output(3)
Output #3
Vnom
Imin
+12 V
+24 V
+12 V
+5.2 V
+3.3 V
+15 V
+24 V
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
0.1 A
3A
0.1 A
1.5 A
0.1 A
3A
0.1 A
3A
0A
1.5 A
0.1 A
2.4 A
0.1 A
1.5 A
Imax
Tol.
5%
5%
5%
5%
5%
5%
5%
Vnom
-12 V
+12 V
+12 V
-15 V
-12 V
Imin
Imax
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
0 A 0.5 A
0 A 0.5 A
0 A 0.5 A
0 A 0.5 A
0 A 0.5 A
Tol.
Power
55 W
60 W
64 W
64 W
64 W
55 W
55 W
55 W
37.5 W
4%
4%
4% 37.5/47.5W(4)
4%
55 W
4%
55 W
Safety approvals are for PCB form only. To order unit with cover fitted, add suffix “C”.
Maximum current of output #1 of multi-output models can be 8 A at 5 CFM forced air provided by user.
The maximum output power shown is convection rating.
47.5W with 5CFM forced air provide by user.
MECHANICAL SPECIFICATIONS
NOTES:
1.
2.
3.
4.
5.
6.
7.
Dimensions shown in inches [mm]
Tolerance 0.02 [0.5] maximum
Input connector mates with Molex housing
09-50-3031 and Molex 2878 series crimp
terminal.
Output connector mates with Molex
housing 09-50-3061 and Molex 2878
series crimp terminal..
Ground tab is 0.25 [6.35] x 0.032 [0.8].
To ensure compliance with level B
emissions, connect the two “*“ marked
mounting holes with metallic standoffs to
chassis.
Weight: 205 grams (0.45 lbs.) approx.
PIN CHART
PIN
1
2
3
4
5
6
+V1
+V1
RTN
RTN
N.C.
N.C.
+V1
+V1
RTN
RTN
N.C.
+V2
+V1
+V1
RTN
RTN
-V3
+V2
+V1
+V1
RTN
RTN
+V3
+V2
MODEL
TMC60-S05
TMC60-S24
TMC60-S12
TMC60-S48
TMC60-D23
TMC60-D25
TMC60-T31
TMC60-T32
TMC60-T31-3 TMC60-T31-5
TMC60-S15
TMC60-T39
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com