37.5-64 WATT MEDICAL & ITE SWITCHING POWER SUPPLIES TRUMPower DESCRIPTION The TMC60 series of compact, open PCB constructed, AC-DC switching power supplies are capable of delivering 37.5-64 watts of continuous output power at convection cooling. They operate at 90-264 VAC input voltage without the need of voltage selection, and are suited for medical, information technology and industrial applications. Approval to both EN 60601-1 and EN 60950-1 safety standards improves design-in time and reduces end equipment compliance costs. TMC60 SERIES FEATURES z z z z z z z Medical and ITE approvals Compact size 2” x 4” x 1.18” Single, dual and triple outputs F u l l r a n g e i n p u t 9 0 - 2 6 4 VA C Low earth leakage current Level B emissions RoHS compliant SAFETY STANDARD APPROVALS UL 60601-1 CSA C22.2 No. 601.1 INPUT SPECIFICATIONS Input voltage: Input frequency: Input current: Earth leakage current: 90-264 VAC 47-63 Hz 1.3 A (rms) for 100 VAC 0.7 A (rms) for 240 VAC 150 µA max. @ 264 VAC, 60 Hz TÜV EN60601-1 GENERAL SPECIFICATIONS Switching frequency: Efficiency: Ripple and noise: Overvoltage protection: Overcurrent protection: Temperature coefficient: Transient response: See rating chart See rating chart 2% peak to peak on 5.0 V model, 1% peak to peak on other models. Provided on output #1 only; set at 112-132% of its nominal output voltage All outputs protected to short circuit conditions o All outputs ±0.04% / C maximum Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 µs after a 25% step load change ENVIRONMENTAL SPECIFICATIONS Operating temperature: Storage temperature: Relative humidity: Derating: o 80-88% typical except TMC60-T31-3 and TMC60-T31-5 at 75% typical OUTPUT SPECIFICATIONS Output voltage/current: Maximum output power: 62±5 KHz o -10 C to +70 C o o -40 C to +85 C 5% to 95% non-condensing o Derate from 100% at +50 C linearly to o 50% at +70 C Hold-up time: 12 msec minimum at 110 VAC Line regulation: ±0.5% maximum at full load Inrush current: 30 A @ 115 VAC, or 60 A @ 230 VAC, Withstand voltage: 4000 VAC from input to output o at 25 C cold start 1500 VAC from input to ground 500 VAC from output to ground MTBF: o 400,000 hours at full load at 25 C ambient, calculated per MIL-HDBK-217F EMC Performance EN55011 / EN55022: Class B conducted, class B radiated FCC: Class B conducted, class B radiated VCCI: Class B conducted, class B radiated EN61000-3-2: Harmonic distortion, class A and D EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8 KV air and ±6 KV contact EN61000-4-3: Radiated immunity, 3 V/m EN61000-4-4: Fast transient/burst, ±2 KV EN61000-4-5: Surge, ±1 KV diff., ±2 KV com. EN61000-4-6: Conducted immunity, 3 Vrms EN61000-4-8: Magnetic field immunity, 3 A/m EN61000-4-11: Voltage dips, 30% reduction for 500 ms 60% reduction for 100 ms >95% reduction for 10 ms Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com UNIVERSAL INPUT TMC60 MEDICAL & ITE SERIES OUTPUT VOLTAGE/CURRENT RATING CHART Output #1 P/N Vnom TMC60-S05 5V TMC60-S12 12 V TMC60-S15 15 V TMC60-S24 24 V TMC60-S48 48 V TMC60-D23 +5 V TMC60-D25 +5 V TMC60-T31 +5 V TMC60-T31-3 +3.3 V TMC60-T31-5 +5 V TMC60-T32 +5 V TMC60-T39 +5 V NOTES: 1. 2. 3. 4. Output #2 Min.-Max.Current Min.-Max.Current Tol. at convection at forced air (2) 0-11 A 0-5 A 0-4.3 A 0-2.7 A 0-1.35 A 0.5-6 A 0.5-6 A 0.5-6 A 0.8-6 A 0.5-6 A 0.5-6 A 0.5-6 A (N/A) (N/A) (N/A) (N/A) (N/A) 0.5-8 A 0.5-8 A 0.5-8 A 0.5-8 A 0.5-8 A 0.5-8 A 0.5-8 A 2% 2% 2% 2% 2% 3% 3% 3% 3% 3% 3% 3% Maximum Output(3) Output #3 Vnom Imin +12 V +24 V +12 V +5.2 V +3.3 V +15 V +24 V (N/A) (N/A) (N/A) (N/A) (N/A) 0.1 A 3A 0.1 A 1.5 A 0.1 A 3A 0.1 A 3A 0A 1.5 A 0.1 A 2.4 A 0.1 A 1.5 A Imax Tol. 5% 5% 5% 5% 5% 5% 5% Vnom -12 V +12 V +12 V -15 V -12 V Imin Imax (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) 0 A 0.5 A 0 A 0.5 A 0 A 0.5 A 0 A 0.5 A 0 A 0.5 A Tol. Power 55 W 60 W 64 W 64 W 64 W 55 W 55 W 55 W 37.5 W 4% 4% 4% 37.5/47.5W(4) 4% 55 W 4% 55 W Safety approvals are for PCB form only. To order unit with cover fitted, add suffix “C”. Maximum current of output #1 of multi-output models can be 8 A at 5 CFM forced air provided by user. The maximum output power shown is convection rating. 47.5W with 5CFM forced air provide by user. MECHANICAL SPECIFICATIONS NOTES: 1. 2. 3. 4. 5. 6. 7. Dimensions shown in inches [mm] Tolerance 0.02 [0.5] maximum Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. Output connector mates with Molex housing 09-50-3061 and Molex 2878 series crimp terminal.. Ground tab is 0.25 [6.35] x 0.032 [0.8]. To ensure compliance with level B emissions, connect the two “*“ marked mounting holes with metallic standoffs to chassis. Weight: 205 grams (0.45 lbs.) approx. PIN CHART PIN 1 2 3 4 5 6 +V1 +V1 RTN RTN N.C. N.C. +V1 +V1 RTN RTN N.C. +V2 +V1 +V1 RTN RTN -V3 +V2 +V1 +V1 RTN RTN +V3 +V2 MODEL TMC60-S05 TMC60-S24 TMC60-S12 TMC60-S48 TMC60-D23 TMC60-D25 TMC60-T31 TMC60-T32 TMC60-T31-3 TMC60-T31-5 TMC60-S15 TMC60-T39 Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com