TRUMPower 55 WATT MEDICAL POWER ADAPTERS TMP55 SERIES D E S C R IP T IO N (MDD) The TMP55 series consists of 15 standard desktop AC/DC switching power adapters with 40 to 55 watts of continuous output power. The units are enclosed in a 94V-1 rated plastic case with an IEC 320 inlet to mate with interchangeable cord for world-wide use. An on/off switch can be added at customer’s request. All models meet CISPR 11 and FCC class B emission limits, and are designed for medical applications. F E AT U R E S ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ 1 5 s ta n d a r d d e s k t o p m o d e l s S i n g l e , d u a l o r t r i p l e o u t p u ts Optional output connectors Optional on/off switch 100% burn-in W i d e i n p u t r a n g e 8 5 t o 2 6 4 VAC Input surge current protection O v e r v o l ta g e p r o t e c t i o n Overcurrent protection S a f e t y Sta n d a r d A p p r o va l s : UL 2601-1 CSA C22.2 No. 601.1 I N P U T S P E C I F I C AT I O N S I n p u t v o l ta g e : 8 5 t o 2 6 4 VA C Input frequency: 47 to 63 Hz Input current: 1 . 5 0 A ( r m s ) f o r 11 5 VA C 0 . 9 0 A ( r m s ) f o r 2 3 0 VA C L e a k a g e c u r r e n t : 9 0 µ A m a x . @ 11 5 VA C , 6 0 H z 1 5 0 µ A m a x . @ 2 3 0 VA C , 5 0 H z TÜV EN60601-1 GENERAL SPECIFICATIONS Switching frequency: 40KHz ±5KHz OUTPUT SPECIFICATIONS Output voltage/current: See rating chart Total output power: 55 watts maximum Ripple and noise: 1% peak to peak maximum Overvoltage protection: Provided on output #1 only; set at 112-132% of its nominal output voltage Efficiency: 70% minimum on single output models with Vo ≥10V, 65% minimum on the others 10 msec minimum at 110VAC ±0.5% maximum at full load Hold-up time: Line regulation: Inrush current: Overcurrent protection: All outputs protected to short circuit conditions Temperature coefficient: All outputs ±0.04%/ºC maximum Transient response: Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500µs after a 25% step load change 15 amps @ 115VAC, or 30 amps @230VAC, at 25ºC cold start Withstand voltage: 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground MTBF: 450,000 hours minimum at full load at 25ºC ambient, calculated per MIL-HDBK-217F EMC performance (EN60601-1-2: 2001) E N 5 5 0 11 : Class B conducted, Class B radiated FCC: Class B conducted, Class B radiated VCCI: Class B conducted, Class B radiated EN61000-3-2: Harmonic distortion, Class A EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8KV air and ±6KV contact EN61000-4-3: Radiated immunity, 3V/m for 80~2500MHz E N V I R O N M E N TA L S P E C I F I C AT I O N S EN61000-4-4: Fast transient/burst, ±2KV O p e r a t i n g t e m p e r a t u r e: 0 º C t o + 7 0 º C Storage temperature: -40ºC to +85ºC 5% to 95% Relative humidity: non-condensing Derating: Derate from 100% at +50ºC linearly to 50% at +70ºC EN61000-4-5: Surge, ±1KV diff, ±2KV com. EN61000-4-6: Conducted immunity, 3Vrms EN61000-4-8: Magnetic field immunity, 3A/m E N 6 1 0 0 0 - 4 - 11 : Voltage dips, 30% reduction for 500ms, 60% reduction for 100ms and >95% reduction for 10ms Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com MEDICAL GRADE TMP55 SERIES OUTPUT VOLTAGE/CURRENT RATING CHART Product No. TMP55-S05 TMP55-S06 TMP55-S09 TMP55-S12 TMP55-S15 TMP55-S19 TMP55-S24 TMP55-S30 TMP55-S36 TMP55-S48 TMP55-D23 TMP55-D24 TMP55-D25 TMP55-T31 TMP55-T32 Notes: (1) (2) Vnom. 5-6V 6-8V 9-11V 11-13V 13-17V 17-21V 21-27V 27-33V 33-39V 48V +5V +5V +5V +5V +5V Output #1 Imin. Imax. 0A 8.0A 0A 7.5A 0A 5.0A 0A 4.6A 0A 3.7A 0A 3.1A 0A 2.3A 0A 1.9A 0A 1.6A 0A 1.2A 1A 5.0A 1A 5.0A 1A 5.0A 1A 5.0A 1A 5.0A Tol. 5% 5% 5% 5% 3% 3% 3% 3% 3% 3% 5% 5% 5% 5% 5% Vnom. +12V +15V +24V +12V +15V Output #2 Imin. Imax. (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) 0.5A 3.0A 0.4A 2.5A 0.3A 2.0A 0.5A 3.0A 0.4A 2.5A Output #3 Vnom. Imin. Imax. (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) -12V 0.1A 0.5A -15V 0.1A 0.5A Tol. 5% 5% 5% 5% 5% Maximum Output Power 40W 45W 50W 55W 55W 55W 55W 55W 55W 55W 45W 45W 45W 45W 45W Tol. 10% 10% The output voltage of a single output model, except TMP55-S48, can be adjusted by user in the stated range, or set by factory to a wanted value in the range at the request of a user when ordering. The output voltages of a multiple output model may go outside of the stated tolerance when an output load current is out of stated limits. All models may be operated at no-load without damage. MECHANICAL SPECIFICATIONS NOTES: 1. Dimensions show in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Weight: 700 grams approx. 4. Standard output connector is a 5-pin at 180º male DIN plug. For other output connector options, please consult TRUMPower. 5. To order a model with on/off switch, add suffix “S”, e.g. TMP55-S12-S PIN CHART PIN 1 2 3 4 5 DC RETURN DC RETURN DC OUTPUT DC RETURN DC OUTPUT COMMOM RETURN COMMOM RETURN OUTPUT #1 COMMOM RETURN OUTPUT #2 COMMOM RETURN COMMOM RETURN OUTPUT #1 OUTPUT #3 OUTPUT #2 Product No. TMP55-S05 TMP55-S12 TMP55-S24 TMP55-S48 TMP55-S06 TMP55-S15 TMP55-S30 TMP55-S09 TMP55-S19 TMP55-S36 TMP55-D23 TMP55-D24 TMP55-D25 TMP55-T31 TMP55-T32 Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com