TRUMPOWER TMP55-S06

TRUMPower
55 WATT MEDICAL POWER ADAPTERS
TMP55 SERIES
D E S C R IP T IO N
(MDD)
The TMP55 series consists of 15 standard
desktop AC/DC switching power adapters with
40 to 55 watts of continuous output power. The
units are enclosed in a 94V-1 rated plastic case
with an IEC 320 inlet to mate with
interchangeable cord for world-wide use. An
on/off switch can be added at customer’s
request. All models meet CISPR 11 and FCC
class B emission limits, and are designed for
medical applications.
F E AT U R E S
‧
‧
‧
‧
‧
‧
‧
‧
‧
1 5 s ta n d a r d d e s k t o p m o d e l s
S i n g l e , d u a l o r t r i p l e o u t p u ts
Optional output connectors
Optional on/off switch
100% burn-in
W i d e i n p u t r a n g e 8 5 t o 2 6 4 VAC
Input surge current protection
O v e r v o l ta g e p r o t e c t i o n
Overcurrent protection
S a f e t y Sta n d a r d A p p r o va l s :
UL 2601-1
CSA C22.2 No. 601.1
I N P U T S P E C I F I C AT I O N S
I n p u t v o l ta g e :
8 5 t o 2 6 4 VA C
Input frequency: 47 to 63 Hz
Input current:
1 . 5 0 A ( r m s ) f o r 11 5 VA C
0 . 9 0 A ( r m s ) f o r 2 3 0 VA C
L e a k a g e c u r r e n t : 9 0 µ A m a x . @ 11 5 VA C , 6 0 H z
1 5 0 µ A m a x . @ 2 3 0 VA C , 5 0 H z
TÜV EN60601-1
GENERAL SPECIFICATIONS
Switching frequency: 40KHz ±5KHz
OUTPUT SPECIFICATIONS
Output voltage/current:
See rating chart
Total output power:
55 watts maximum
Ripple and noise:
1% peak to peak maximum
Overvoltage protection:
Provided on output #1 only;
set at 112-132% of its
nominal output voltage
Efficiency:
70% minimum on single
output models with Vo ≥10V,
65% minimum on the others
10 msec minimum at 110VAC
±0.5% maximum at full load
Hold-up time:
Line regulation:
Inrush current:
Overcurrent protection:
All outputs protected to short
circuit conditions
Temperature coefficient: All outputs ±0.04%/ºC
maximum
Transient response:
Maximum excursion of 4% or
better on all models,
recovering to 1% of final
value within 500µs after a
25% step load change
15 amps @ 115VAC, or 30 amps
@230VAC, at 25ºC cold start
Withstand voltage:
4000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
MTBF:
450,000 hours minimum at full load at
25ºC ambient, calculated per
MIL-HDBK-217F
EMC performance (EN60601-1-2: 2001)
E N 5 5 0 11 :
Class B conducted, Class B radiated
FCC:
Class B conducted, Class B radiated
VCCI:
Class B conducted, Class B radiated
EN61000-3-2:
Harmonic distortion, Class A
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ±8KV air and ±6KV contact
EN61000-4-3:
Radiated immunity, 3V/m for 80~2500MHz
E N V I R O N M E N TA L S P E C I F I C AT I O N S
EN61000-4-4:
Fast transient/burst, ±2KV
O p e r a t i n g t e m p e r a t u r e: 0 º C t o + 7 0 º C
Storage temperature: -40ºC to +85ºC
5% to 95%
Relative humidity:
non-condensing
Derating:
Derate from 100% at +50ºC
linearly to 50% at +70ºC
EN61000-4-5:
Surge, ±1KV diff, ±2KV com.
EN61000-4-6:
Conducted immunity, 3Vrms
EN61000-4-8:
Magnetic field immunity, 3A/m
E N 6 1 0 0 0 - 4 - 11 :
Voltage dips, 30% reduction for 500ms,
60% reduction for 100ms and >95%
reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com
MEDICAL GRADE
TMP55 SERIES
OUTPUT VOLTAGE/CURRENT RATING CHART
Product No.
TMP55-S05
TMP55-S06
TMP55-S09
TMP55-S12
TMP55-S15
TMP55-S19
TMP55-S24
TMP55-S30
TMP55-S36
TMP55-S48
TMP55-D23
TMP55-D24
TMP55-D25
TMP55-T31
TMP55-T32
Notes:
(1)
(2)
Vnom.
5-6V
6-8V
9-11V
11-13V
13-17V
17-21V
21-27V
27-33V
33-39V
48V
+5V
+5V
+5V
+5V
+5V
Output #1
Imin.
Imax.
0A
8.0A
0A
7.5A
0A
5.0A
0A
4.6A
0A
3.7A
0A
3.1A
0A
2.3A
0A
1.9A
0A
1.6A
0A
1.2A
1A
5.0A
1A
5.0A
1A
5.0A
1A
5.0A
1A
5.0A
Tol.
5%
5%
5%
5%
3%
3%
3%
3%
3%
3%
5%
5%
5%
5%
5%
Vnom.
+12V
+15V
+24V
+12V
+15V
Output #2
Imin. Imax.
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
0.5A
3.0A
0.4A
2.5A
0.3A
2.0A
0.5A
3.0A
0.4A
2.5A
Output #3
Vnom. Imin. Imax.
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
-12V
0.1A
0.5A
-15V
0.1A
0.5A
Tol.
5%
5%
5%
5%
5%
Maximum
Output
Power
40W
45W
50W
55W
55W
55W
55W
55W
55W
55W
45W
45W
45W
45W
45W
Tol.
10%
10%
The output voltage of a single output model, except TMP55-S48, can be adjusted by user in the stated range, or set by factory to a
wanted value in the range at the request of a user when ordering.
The output voltages of a multiple output model may go outside of the stated tolerance when an output load current is out of stated limits.
All models may be operated at no-load without damage.
MECHANICAL SPECIFICATIONS
NOTES:
1.
Dimensions show in inch [mm]
2.
Tolerance 0.02 [0.5] maximum
3.
Weight: 700 grams approx.
4.
Standard output connector is a 5-pin at
180º male DIN plug. For other output
connector options, please consult
TRUMPower.
5.
To order a model with on/off switch, add
suffix “S”, e.g. TMP55-S12-S
PIN CHART
PIN
1
2
3
4
5
DC
RETURN
DC
RETURN
DC
OUTPUT
DC
RETURN
DC
OUTPUT
COMMOM
RETURN
COMMOM
RETURN
OUTPUT
#1
COMMOM
RETURN
OUTPUT
#2
COMMOM
RETURN
COMMOM
RETURN
OUTPUT
#1
OUTPUT
#3
OUTPUT
#2
Product No.
TMP55-S05
TMP55-S12
TMP55-S24
TMP55-S48
TMP55-S06
TMP55-S15
TMP55-S30
TMP55-S09
TMP55-S19
TMP55-S36
TMP55-D23
TMP55-D24
TMP55-D25
TMP55-T31
TMP55-T32
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com