AC/DC Power Supplies TOP 100 Series, 100 Watt CB Scheme Features ◆ 100 W power supply in 2.0”x 4.0“ footprint! ◆ Full load operation up to +50°C with UL 60950-1 convection cooling ◆ Highest efficiency, 90 % typ. ◆ EMI filter meets EN 55022, level B ◆ Compliance with EN 61000-3-2 ◆ Low leakage current ◆ Safety class l and class ll operation ◆ 3-year product warranty The new TOP-100 Series AC/DC Power Supplies feature the highest power rating in the industry standard 2.0” x 4.0” (50.8 x 101.6 mm) footprint. They can supply up to 100 W output power with convection cooling over an industrial operating temperature range of –25°C to +50°C. This performance could be realized by a state of the art design providing an extremely high efficiency of >90 % which eliminates the need for a dedicated power supply cooling fan. Also see: www.tracopower.com/products/top100_article_e1.pdf Compliance with global safety and EMC standards qualify these power supplies for worldwide markets. Approved for Class l and Class ll applications, these switchers are suitable for industrial and IT systems but also for consumer products. High reliability is provided by use of industrial quality grade components and an excellent thermal management. This product offers an interesting power supply solution for many space and cost critical applications in commercial and industrial electronic equipment. Models Order Code Output Voltage (Adjustment Range) Output Current max. TOP 100-103 3.3 VDC (3.3 - 3.5) 20.0 A TOP 100-105 5.0 VDC (5.0 - 5.2) 20.0 A TOP 100-112 12 VDC (12.0 - 13.0) 8.3 A TOP 100-115 15 VDC (15.0 - 16.0) 6.7 A TOP 100-124 24 VDC (24.0 - 26.0) 4.2 A TOP 100-148 48 VDC (48.0 - 52.0) 2.1 A http://www.tracopower.com Page 1 of 4 AC/DC Power Supplies TOP-100 Series 100 Watt Input Specifications Input voltage range 90 – 132 / 187 – 264 VAC autorange power derating at low input voltage: 50 % at 90 VAC – 0% at 103 VAC 20 % at 187 VAC – 0% at 207 VAC Input frequency 47 – 63 Hz Input protection T4 A/250 V internal fuse in both line & neutral Harmoni limits EN 61000-3-2, class A Zero load power consumption 3.6 W Recommended circuit breaker 6 A (characteristic C) or slow blow fuse Output Specifications Regulation – Input and Load variation 1.0 % max. Ripple and noise (20Mhz Bandwidth) <100 mVp-p 48 VDC model: <200 mVp-p Overvoltage protection 3.3 5.0 12 15 24 48 VDC VDC VDC VDC VDC VDC model: model: model: model: model: model: 5.0 V 6.0 V 16 V 20 V 30 V 60 V Power back immunity 3.3 5 12 15 24 48 VDC VDC VDC VDC VDC VDC model: model: model: model: model: model: 5.0 V (6.0 V for 1 sec) 6.3 V (7.0 V for 1 sec) 16 V (18 V for 1 sec) 20 V (23 V for 1 sec) 35 V (40 V for 1 sec) 63 V (68 V for 1 sec) Overload protection by current limit at 150 % Iout max. Short circuit protection foldback (automatic recovery) Capacitive load 10’000 µF max. General Specifications Operating temperature – 25°C to +70°C with derating Power derating depending on temperature Convection Cooling Forced Air Cooling 5 CFM (300 LFM) 80 80 tput Power [W] 100 Output Power [W] 100 60 40 20 0 60 40 20 -25 0 20 40 60 80 0 -25 Ambient Temperature [°C] For horizontal mounting 0 20 40 60 80 Ambient Temperature [°C] 3.3 VDC model 5 VDC model other models Temperature coefficient 0.02 %/K Reliability, calculated MTBF @ 25°C acc. to IEC 61709 http://www.tracopower.com 3.3 – 12 VDC models: >1.0 Mio h 15 – 48 VDC models: >1.4 Mio h Page 2 of 4 AC/DC Power Supplies TOP-100 Series 100 Watt General Specifications Humidity (non condensing) 0 – 95 % rel. H max. Efficiency – Vin = 115 VAC 89 – 91 % – Vin = 230 VAC 90 – 92 % Switching frequency 100 kHz typ. (pulse width modulation) Hold-up time – Vin = 115 VAC 10 ms typ. – Vin = 230 VAC 15 ms typ. Start-up time – Vin = 115 VAC <3.5s – Vin = 230 VAC <2s Isolation voltage – Input / Output 4000 VAC – Input / Field Ground 2000 VAC – Output / Field Ground 500 VAC Isolation resistance (at 500 VDC) 100 Mohm min. Earth leakage current 250 µA max. Isolation class class II double isolation Electromagnetic compatibility – Conducted input RI suppression EN 55022, class B (conductive plane to be (EMC), emissions connected to safety earth) – Harmonic current emissions IEC / EN 61000-3-2, class A Electromagnets compatibility – Electrostatic discharge ESD (EMC), immunity – RF field immunity – Electrical fast transients/burst immunity – Surge – Conducted RF – Voltage dip IEC / EN 61000-4-2 IEC / EN 61000-4-3 IEC / EN 61000-4-4 IEC / EN 61000-4-5 IEC / EN 61000-4-6 IEC / EN 61000-4-11 Safety approvals and – CB test certificate certifications – CSA certificate – GS certificate for IEC/EN 60950-1 www.tracopower.com/products/top100-cb.pdf UL 60950-1, CSA 60950-1-03 www.tracopower.com/products/top100-csa.pdf www.tracopower.com/products/top100-gs.pdf Environment – Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10-55Hz, 1g, 1oct/min – Shock acc. IEC 60068-2-27 3 axis, 15g half sine, 11msShock 20 G (3 directions each 3 times) Connection pin connector (Molex) Weight 140 g (4.9 oz) All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 3 of 4 AC/DC Power Supplies TOP-100 Series 100 Watt Dimensions 4.0 (101.6) 2.0 (50.8) OUT Field Ground 4x ø 0.157 (4.0) 1.25 (31.8) J2 1 1.75 (44.5) 1 J1 AC IN 0.14 (3.6) 3.75 (95.3) 6 Dimensions in Inch, () = mm 4x Pillars (not included) for connection to safety earth: Height: 0.2 min. (5.0), Diam.: 0.25 max. (6.0) Input Output Pin J1 Pin J2 1 AC in 1 – Vout 2 AC in 2 – Vout 3 – Vout 4 + Vout 5 + Vout 6 + Vout J1: Molex Series 41791 mates with Molex crimp terminal: 08-52-0072 and terminal housing: 09-50-3031 J2: Molex Series 41791 mates with Molex crimp terminal: 08-52-0072 and terminal housing: 09-50-3061 Specifications can be changed any time without notice. Rev. 05/09 Jenatschstrasse 1 · CH-8002 Zurich · Switzerland Tel. +41 43 311 45 11 · Fax +41 43 311 45 45 · [email protected] · www.tracopower.com Page 4 of 4