ETC TR/C5191.25A

Bussmann®
Time-Delay Glass Fuses
C519
5mm x 15mm
R
C519 Time Delay Fuses
100
250mA
350mA
500mA
750mA
1A
1.25A
1.5A
2.5A
3A
Time-Current Characteristic Curves–Average Melt
(Full Size Curves Available)
AMPERE
RATING
Dimensional Data
15.0 ± 0.5mm
5.2 ± 0.3mm
5.0mm (Typ.)
Markings: Manufacturer’s Symbol,
Product Symbol, Voltage, Ampere,
Testing Agency Mark (Optional)
Dimensions are in
Millimeters (mm)
TIME IN SECONDS
10
1
Limits for Pre-arcing Time/UL Listed Fuses.
Amp Ratings
135%
MAX
MIN
200%
MAX
125mA - 5A
60 min.
3 sec.
2 min.
.1
2A
MAX
6A
MAX
350mA
240 min.
90 sec.
2 sec.
500 millisec.
.1
.01
Product Symbol:
C519
Physical Fuse Size:
5 x 15mm
Mechanical Characteristics:
Materials:
Endcaps are silver-plated brass; leads are
tin-plated copper and tube is glass.
Temp. Range: -55°C to +85°C with proper derating.
CURRENT IN AMPERES
100
AMPERE
RATING
10
TIME IN SECONDS
Agency File Numbers: UL Listing.
Guide # JDYX, File E75865
CSA Certification.
Class 1422-01, File LR65063
UL Recognized.
Guide # JDYX2, File E75865d
100
600mA
MAX
3.5A
5A 4A
350mA
MIN
1
Amp Ratings
10
Limits for Pre-arcing Time/UL Recognized Fuses.
1
.1
100
10
.1
.01
1
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000V AC, 75-1500V DC). Refer to BIF document #8002 or contact
Bussmann Application Engineering at 314-527-1270 for more information.
CURRENT IN AMPERES
12-17-98
SB98107
Rev. A
Form No. C519
Page 1 of 2
BIF Doc #2007
Bussmann®
Time-Delay Glass Fuses
C519
5mm x 15mm
R
375mA
500mA
600mA
750mA
1A
1.25A
1.5A
1.6A
2A
2.25A
2.5A
3A
3.5A
4A
5A
250V
AIR
35A/250V 10kA/125V AC
p.f. = 0.7 - 0.8
35A/250V 10kA/125V AC
25A/600V p.f. = 0.7 - 0.8
35A/250V AC
10kA/125V AC
p.f. = 0.7 - 0.8
100A/250V AC
10ka/125V AC
p.f. = 0.7 - 0.8
125V
400A/125V AC
p.f. = 1.0
Telecommunication Capabilities:
UL 1459: Telephone Equipment
Fuses successfully opened:
600 Volts (AC) 40 Amps
600 Volts (AC)
7 Amps
600 Volts (AC) 2.2 Amps
UL 497: Protectors for Paired Conductor
Communication Circuits
Fuses successfully passed without opening:
10 x 1000 microsecond waveform
50 pulses/1 pulse every 8 seconds†
@ 1000V
Fuse Rating
250mA
350mA
375mA
500mA
600mA
750mA
1A
1.25A
Peak Current (A)
12.5
19.5
20.0
28.5
36.5
49.0
66.5
100.0
Voltage
Drop
(mV) max.
1200
630
520
Pre-arcing
Value
(I2t) (A2s) typ.
0.039
0.18
0.9
490
410
350
300
250
220
200
200
200
200
190
190
180
150
150
0.9
1.1
2.7
2.7
6.4
7.6
13
14
27
31
42
94
94
145
230
•
•
CSA
Rated
Voltage
(V)AC
U.R.
Current
Rating
125mA
250mA
350mA
U.L.
Electrical Characteristics:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Packaging & Ordering Information:
C519
Product
Symbol
Package Code
BK/ Bulk Package (100 pcs)
TR/ Tape & Reel (500 pcs)
TR1/ Tape & Reel (1,000 pcs)
TR2/ Tape & Reel (1,500 pcs)
NOTE: Tape & Reel Packaging
per EIA 296-E (10.2mm Component
Pitch and 52.4mm Tape-to-Tape Spacing)
Blank - Standard
S - Transparent
Sleeve for
sealed fuses.
Ampere
Rating
125mA
250mA
350mA
375mA
500mA
600mA
750mA
1A
1.25A
1.5A
1.6A
2A
2.25A
2.5A
3A
3.5A
4A
5A
† Fuse resistance was not allowed to vary by more than five percent after
completion of the test.
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled. This bulletin is intended to
clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any
products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
12-17-98
SB98107
Rev. A
Form No. C519
Page 2 of 2
BIF Doc #2007