• VDR-120-12 Single Output DIN Rail Power Supply Features ·Low cost ·105°C output capacitor ·AC Input range selected by switch ·High efficiency, low working temperature ·Soft-start circuit, limiting AC surge current ·Short circuit, overload, over-voltage protected ·Compact size, light weight ·100% full load burn-in test ·Built in EMI filter, low ripple noise ·Din rail mountable DC output voltage Output V. tolerance Output rated current Output current range Ripple & noise Line regulation Load regulation DC output power Efficiency DC voltage adj. Input voltage range AC current Inrush current Leakage current Overload protection Over voltage protection Over temp. protection Temperature coefficient Set up, rise, hold up time Vibration Withstand voltage Isolation resistance Working temp., humidity Storage temp., humidity Dimensions Weight Safety standards EMC standards Notes: 12V ±2% 10A 0-10A 80mVp-p ±0.5% ±1% 120W 80% 12-14V 88~132VAC/176~264VAC selected by switch, 47~63Hz; or 254~370VDC 2.8A/115V 1.7A/230V cold start 30A/115V 60A/230V <3.5mA/240VAC 105%~150% type: constant current limiting, auto recovery 15~16.5V 85 ºC±5 ºC (TSW1) ±0.03% / °C (0~50°C) 500ms;70ms; 30ms/230V,115V 10~500Hz, 2G 10min./1cycle (1 hour each axes) I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min. I/P-O/P, I/P-FG, O/P-FG: 500VDC / 100M Ohms min. -10°C~+60% (refer to output derating curve), 20%-90% RH -20ºC~+85ºC, 10%~95% RH 2.58x4.93x3.94 inches (65.5x125.2x100mm) 1.76 lbs (0.8Kgs) TUV EN60950, UL508 EN55022 CLASS B, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-3-2,-3 1. All parameters are specified at 230VAC input, rated load, 25°C 70% ambient 2. Tolerance includes set up tolerance, line regulation, load regulation 3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor 4. Line regulation is measured from low line to high line at rated load 5, Load regulation is measure from 0% to 100% rated load *V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty. V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 www.v-infinity.com 1-866-372-1258 • VDR-120-12 Single Output DIN Rail Power Supply Block Diagram Output Derating Static Characteristics Dimensions (mm) V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 www.v-infinity.com 1-866-372-1258