DESCRIPTION: ac-dc converter
PART NUMBER: VSK-S3-XXU series
features
•
•
•
•
•
•
•
•
•
•
universal input 85~264 Vac/ 110~370 VDC
encapsulated, compact case
high efficiency
surface mounting technology
100kHz fixed frequency
fixed output voltage
thermal shutdown
output short circuit protection
low output ripple and noise
isolated output
model
VSK-S3-3R3U
VSK-S3-5U
VSK-S3-9U
VSK-S3-12U
VSK-S3-15U
VSK-S3-24U
output
(Vo1/Io1)
3.3V/700mA
5V/600mA
9V/330mA
12V/250mA
15V/200mA
24V/125mA
output
(Iomax/T)
900mA/60S
750mA/60S
450mA/60S
330mA/60S
250mA/60S
160mA/60S
power
max.
2.3 W
3.0 W
3.0 W
3.0 W
3.0 W
3.0 W
ripple & noise
max.
30 mVp-p
30 mVp-p
30 mVp-p
30 mVp-p
30 mVp-p
30 mVp-p
INPUT
parameter
input frequency
input voltage
input current
inrush current
leakage current
conditions/description
output power derated from 85-90 VAC
min
47
85
110
nom
(50~60)
max
440
264
370
65
30
10
20
units
Hz
VAC
VDC
mA
mA
A
A
min
-2%
-3%
-5%
nom
max
+2%
+3%
+5%
100
units
AC input of 110 VAC
AC input of 230 VAC
measured at 110 VAC at full load, cold start
measured at 220 VAC at full load, cold start
none
OUTPUT
parameter
voltage tolerance
line regulation
load regulation
rise time
hold-up time
conditions/description
±3% for 3.3V output
10% to 100%
Vin = 230 V ac
50
mS
mS
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
efficiency
(%)
63
72
74
76
76
78
rev.
PART NUMBER: VSK-S3-XXU series
page
2 of 4
date
06/2008
DESCRIPTION: ac-dc converter
PROTECTION CIRCUIT
parameter
over temperature
over voltage
conditions/description
150 ºC max.
chip lock up
GENERAL
parameter
operating temp.
storage temp.
case temp.
power derating
humidity
storage humid.
isolation voltage
(HI-POT)
MTBF
RoHS
case material
safety
EMC 1
warranty
conditions/description
above 55°C
min
-25
-40
nom
2
max
70
105
95
units
ºC
ºC
°C
%/°C
RH
RH
95%
non-condensing
20%
90%
applied for 1 minute
primary to secondary, 500 Vdc @ 100 MΩ
3000
VAC
at 25°C
200,000
hours
yes
UL94V-0
IEC60950, approved to EN60950, UL60950
IEC/EN 61000-4-2 level 4 (8kV/15kV), IEC/EN 61000-4-2, IEC/EN 61000-4-4 level 3 (2kV),
IEC/EN 61000-4-4 level 4 (4kV), IEC/EN 61000-4-5 level 3 (1kV/2kV), IEC/EN 61000-4-5 level 4 (2kV/4kV)
standard warranty length
2
years
TEMPERATURE VS LOAD
INPUT VOLTAGE VS LOAD
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
rev.
PART NUMBER: VSK-S3-XXU series
DESCRIPTION: ac-dc converter
TYPICAL EFFICIENCY CURVE
TYPICAL EFFICIENCY CURVE
page
3 of 4
date
06/2008
Connect Oscillograph probe
Copper sheet
Fuse
C3
C1
C2
Load
3
25.4mm
25.4mm
TYPICAL EFFICIENCY CURVE
L
* FUS E * NT C
L
M OV
C3
+
+V0
C1
C2
+
22
* F USE * NT C
L
Tvs
L
NF
RL
C7
C6
26
MO V
C3
+
C8
N
C1 C2 Tvs
+
22
RL
26
- V0
N
+V0
-V0
N
N
Figure1
Figure 2 VSK-S3 EMC Application Figure
EXTERNAL CAPACITORS TYPICAL VALUE(Unit: µF)
model
C1
C2
C3
TVS
VSK-S3-3R3U
150
0.1
4.7/400V
P4KE6.8A
VSK-S3-5U
150
0.1
4.7/400V
P4KE6.8A
VSK-S3-9U
150
0.1
4.7/400V
P4KE12A
VSK-S3-12U
150
0.1
4.7/400V
P4KE20A
VSK-S3-15U
150
0.1
4.7/400V
P4KE20A
VSK-S3-24U
150
0.1
4.7/400V
P4KE30A
Note!
1. Output filtering capacitors C1, C3 is electrolytic capacitors, It is recommended to use high frequency and low impedance electrolytic capacitors. For
capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. C2, C4 is ceramic
capacitors , it is used to filter high frequency noise. TVS is a recommended component to protect post-circuits (when converter fails).
2. MOV is required for VSK-S3 models. Model: 471KD05, it is used to protect the device under surge.
3. It is recommended to connect FUSE, the parameter is 0.5A/250V slow blow. External input NTC is recommended to use
D -14 or 10Ω/2W wire-round resistor.
4. If EMC performance is required, recommended to add “EMC filter” at the input end(see figure 2)
C6:X capacitor, recommended parameter 0.1uF/275V;
C7,C8:Y capacitor, recommended parameter 220pF/2000V;
NF: common model choke, recommended inductance is about 10mH-30mH.
5. Terminals 22 and 26 are internal rectification and filtering terminals. To protect the models further, it is recommended to connect an electrolytic
capacitor C3 (it is recommended to be 4.7uF/400V). If operation voltage of the module is between 160~264VAC, C3 can be removed.
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
REV.
A
37.00 1.457
DESCRIPTION
NEW DRAWING
DATE
4/2/2008
15.00 0.591
4.10 0.161
(TYP)
0.80 0.031
(7 PLCS)
3.26 0.128
(2 PLCS)
8.34 0.328
1
3
2.61 0.103
(TYP)
13
23.00 0.906
17.78 0.700
SCALE: 1:1
26
22
3.26 0.128
(2 PLCS)
16
14
5.08 0.200
(TYP)
BOTTOM VIEW
13.42 0.528
1.2 0.047
(7 PLCS)
26
1
22
3
PC FILE NAME:
VSK-S3-XXU
TOLERANCE:
±0.5mm UNLESS OTHERWISE
SPECIFIED
RECOMMENDED FOOTPRINT
TOP VIEW
2.54
COPYRIGHT 2008 BY CUI INC.
16
NOTE:
PIN DIAMETER: 0.80±0.05mm
WEIGHT: 25g
RoHS
14
13
20050 SW 112th Ave.
Tualatin, OR 97062
FOOTPRINT DETAILS
Phone: 503-612-2300
PIN
FUNCTION
800-275-4899
Fax: 503-612-2383
1
L
Website: www.cui.com
3
N
TITLE:
REV:
SWITCHING POWER SUPPLY
13
NC
A
14
-Vo
PART NO.
UNITS:
VSK-S3-XXU
16
+Vo
MM [INCHES]
22
+Vin(DC)
APPROVED BY:
SCALE:
DRAWN BY:
ZRJ
2:1
26
-Vin(DC)
NC: no connection