Power Relay 415 2 pole 16 A Features · · · · 2 N/O contacts, 16 A Fast-on connectors 6.3 x 0.8 mm Contact gap > 3 mm 4 kV / 8 mm coil-contact Applications Power Supplies, domestic appliances, heating controls V KSND Contact data Configuration Type of contact Rated current Rated voltage / max.breaking voltage AC Max. breaking voltage DC Maximum breaking capacity AC Make current (max. 4 s at duty cycle 10%) Peak inrush current 20 msw Contact material Contact ratings Type Load 41501 / 04 16 A, 250 Vac, cosj=1 Coil data Nominal voltage Nominal coil power Edition: 10/2002 Operate category DC coil AC coil DC coil AC coil 2 N/O contacts single contact 16 A 250 Vac / 440 Vac 250 Vdc 4000 VA 25 A 25 A AgCdO Operations 1x105 12...220 Vdc 24...380 Vdc 1.3 W 2.8 VA 1/b Coil versions DC-coil Coil Nominal Pull-in Release Maximum Coil Coil code voltage voltage voltage voltage resistance current Vdc Vdc Vdc Vdc c mA 031 12 7.0 0.9 14.5 125+10% 96.0 029 24 14.0 1.8 39.0 435+10% 55.2 025 220 130.0 11.0 323.0 32800+15% 6.7 All figures are given for coil without preenergization, at ambient temperature +20°C Other coil voltages on request Power Relay 415 2 pole 16 A Coil versions AC-coil Coil Nominal code voltage Vac 015 24 010 220 008 230 009 380 Pull-in voltage Vac 19.0 187.0 176.0 304.0 Release voltage Vac 1.8 16.5 17.3 28.5 Maximum voltage Vac 28.8 264 276 456 Coil resistance c 69+10% 5700+15% 6000+15% 10000+15% Coil current mA 116.0 13.0 12.0 7.0 Dimensions Dimensions in mm 41501 All figures are given for coil without preenergization, at ambient temperature +20°C Other coil voltages on request Dielectric strength coil-contacts open contact circuit Clearance / creepage Insulation to IEC 60664 Voltage rating Pollution degree Overvoltage category Insulation to VDE 0110b (2/79) Insulation category / reference voltage Tracking resistance of relay base Other data Flammability class according to UL 94 Ambient temperature Mechanical life Max. switching rate at rated- / minimum load Operate- / release time Bounce time Shock resistance (destruction) Category of protection (IEC 61810) Relay weight Packaging unit 4000 Vrms 2000 Vrms 8 mm 250 V 3 III B / 400, C / 250 CTI 600 M V-0 -20...+70 °C 10x106 operations 10 min-1 / 600 min-1 typ. 15 / 10 ms typ. 5 ms 100 g RT I (dust protection) 80 g 25 pcs. S0469-AA 41504 Edition: 10/2002 S0469-AB Rights to change data / design reserved Insulation