MA-COM 41501008002

Power Relay 415
2 pole 16 A
Features
·
·
·
·
2 N/O contacts, 16 A
Fast-on connectors 6.3 x 0.8 mm
Contact gap > 3 mm
4 kV / 8 mm coil-contact
Applications
Power Supplies, domestic appliances, heating controls
V KSND
Contact data
Configuration
Type of contact
Rated current
Rated voltage / max.breaking voltage AC
Max. breaking voltage DC
Maximum breaking capacity AC
Make current (max. 4 s at duty cycle 10%)
Peak inrush current 20 msw
Contact material
Contact ratings
Type
Load
41501 / 04
16 A, 250 Vac, cosj=1
Coil data
Nominal voltage
Nominal coil power
Edition: 10/2002
Operate category
DC coil
AC coil
DC coil
AC coil
2 N/O contacts
single contact
16 A
250 Vac / 440 Vac
250 Vdc
4000 VA
25 A
25 A
AgCdO
Operations
1x105
12...220 Vdc
24...380 Vdc
1.3 W
2.8 VA
1/b
Coil versions DC-coil
Coil
Nominal
Pull-in
Release
Maximum
Coil
Coil
code
voltage
voltage
voltage
voltage
resistance
current
Vdc
Vdc
Vdc
Vdc
c
mA
031
12
7.0
0.9
14.5
125+10%
96.0
029
24
14.0
1.8
39.0
435+10%
55.2
025
220
130.0
11.0
323.0
32800+15%
6.7
All figures are given for coil without preenergization, at ambient temperature +20°C
Other coil voltages on request
Power Relay 415
2 pole 16 A
Coil versions AC-coil
Coil
Nominal
code
voltage
Vac
015
24
010
220
008
230
009
380
Pull-in
voltage
Vac
19.0
187.0
176.0
304.0
Release
voltage
Vac
1.8
16.5
17.3
28.5
Maximum
voltage
Vac
28.8
264
276
456
Coil
resistance
c
69+10%
5700+15%
6000+15%
10000+15%
Coil
current
mA
116.0
13.0
12.0
7.0
Dimensions
Dimensions in mm
41501
All figures are given for coil without preenergization, at ambient temperature +20°C
Other coil voltages on request
Dielectric strength
coil-contacts
open contact circuit
Clearance / creepage
Insulation to IEC 60664
Voltage rating
Pollution degree
Overvoltage category
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage
Tracking resistance of relay base
Other data
Flammability class according to UL 94
Ambient temperature
Mechanical life
Max. switching rate at rated- / minimum load
Operate- / release time
Bounce time
Shock resistance (destruction)
Category of protection (IEC 61810)
Relay weight
Packaging unit
4000 Vrms
2000 Vrms
8 mm
250 V
3
III
B / 400, C / 250
CTI 600 M
V-0
-20...+70 °C
10x106 operations
10 min-1 / 600 min-1
typ. 15 / 10 ms
typ. 5 ms
100 g
RT I (dust protection)
80 g
25 pcs.
S0469-AA
41504
Edition: 10/2002
S0469-AB
Rights to change data / design reserved
Insulation