MA-COM W68-X2Q12-30

W6/W9 series
Magnetic Hydraulic
Circuit Breakers
Typical Resistance and Impedance
Features
• Designed for the international market. UL Recognized, CSA Certified,
and VDE approved.
• Ratings to 50 amps.
• Heavy duty #10-32 stud connections. (W9)
• Optional 10 amp auxiliary switch.
• Optional snap-in mounting. (W6)
• Several delay curve options.
• Trip-free operation.
Current
(Amps)
0.2
1.0
2.0
5.0
10.0
20.0
30.0
40.0
50.0
DC
Resistance
(Ohms)
90
1.2
0.28
0.04
0.013
0.004
0.0027
0.002
0.0015
50/60 Hz.
Impedance
(Ohms)
90
1.2
0.28
0.04
0.013
0.005
0.004
0.002
0.0015
400 Hz.
Impedance
(Ohms)
180
2.0
0.50
0.05
0.025
0.0065
0.004
0.003
0.0025
Tolerance: 0.1 - 4.99 ± 15%; 5 - 9.99 ± 20%; 10 - 15 ± 25%; 16 - 30 ± 50%.
Agency Approvals
Mechanical/Environmental Data
UL:
Operating Temperature: -40°C to +85°C.
Humidity: Meets requirements of Mil-STD-202 method 103.
Shock: Tested per Mil-STD-202, method 213, test condition C
(100g @ 6 ms).
Vibration:Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06" (1.52mm)
total excursion in 2 planes.
Fungus And Moisture Resistance: Special moisture resistant finish
applied to all ferrous parts.
Plastic parts are made of inherently
fungus resistant material.
Marking: W6 units have ON and OFF molded on the rocker of rocker
actuated units (rocker actuated VDE units have international
“1” and “0”). W9 units have ON and OFF molded into the area
at the base of the toggle. International “1” and “0” symbols are
marked on the toggle for both W6 and W9.
Mounting: Panel mounted units are mounted with two #6-32 screws
from the front of the panel. Metric models for use with M3 x
0.5 screws are available. Units with snap-in mounting option
snap through the front of the panel. To maintain published
performance specifications, units should not be mounted
more than 90° from their normal upright position.
Weight: Approximately 2.5 ounces per pole.
Recognized as Supplementary Protector under UL 1077. File
E69543.
CSA: Certified as a Supplementary Protector. File LR15734.
VDE: Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment)
License No. 73782.
Electrical Data
Auxiliary Switch: See Auxiliary Switch Ratings Table 2 for details.
Calibration: Breakers will hold 100% of rated current. Breakers may trip
between 101% and 124% of rated load (149% for 400 Hz.
units and 134% for AC/DC units). Breakers must trip at
125% of rated load and above (150% for 400 Hz. units and
135% for AC/DC units).
Dielectric Strength: 50/60 or 400 Hz., 1500V: DC, 1100V.
Insulation Resistance: 100 Megohms at 500VDC.
Endurance: 10,000 on/off cycles - 6000 at rated load, 4000 at no load.
Units tested at six cycles per minute, 1 second on and 9
seconds off at 25°C ambient.
Approvals and Ratings Table 1
W6 Series
Maximum
Voltage
65
277
277
277/480
250
250
250
W9 Series
Maximum
Voltage
65
277
277/480
250
250
UL/CSA (All Circuit Functions)
Frequency
(Hz)
DC
50/60
50/60
50/60
400
400
400
Current
Phase
1
1
3Ø-Wye
1
1
3Ø-Wye
Interrupting
Rating
(Amps)
0.2 - 50
0.2 - 20
21 - 50
0.2 - 20
0.2 - 20
21 - 50
0.2 - 20
W6 Series
Capacity
(Amps)
2,000
5,000
2,500
5,000
2,500
1,250
2,500
UL/CSA (All Circuit Functions)
Frequency
(Hz)
DC
50/60
50/60
400
400
Current
Phase
1
3Ø-Wye
1
3Ø-Wye
Interrupting
Rating
(Amps)
0.2 - 50
0.2 - 50
0.2 - 20
0.2 - 50
0.2 - 50
Maximum
Voltage
65
250
250
415/240
W9 Series
Capacity
(Amps)
2,000
5,000
5,000
2,500
2,500
Maximum
Voltage
65
250
250
415/240
VDE (Circuit Function X)
Frequency
(Hz)
DC
50/60
50/60
50/60
Current
Phase
1
1
3Ø
Interrupting
Rating
(Amps)
0.2-50
0.2-30
31-50
0.2-30
Capacity
(Amps)
2,000
5,000
2,000
5,000
VDE (Circuit Function X)
Frequency
(Hz)
DC
50/60
50/60
50/60
Current
Phase
1
1
3Ø
Interrupting
Rating
(Amps)
0.2-50
0.2-30
31-50
0.2-30
Capacity
(Amps)
2,000
5,000
2,000
5,000
Approvals and Ratings Table 2
UL/CSA
Switch
Number
A
VDE
Voltage
50/60 Hz.
125
Current
(Amps)
10
Terminals
WxTxL
.093 x .020 x .250
(2.36 x .51 x 6.40)
Switch
Number
V1
V2
V3
Voltage
50/60 Hz.
250
250
250
Current
(Amps)
10
5
0.1
Terminals
WxTxL
.110 x .020 x .280
(2.79 x .51 x 7.11)
Time vs. Current Trip Curves For W6 Series and W9 Series
AC 50/60 Hz.
DC & 50/60 Hz.
125%
150%
200%
400%
600%
800%
100
10
100 ms max.
55 ms max.
30 ms max.
15 ms max.
12 ms max.
12 ms max.
May Trip
100 ms max.
30 ms max.
15 ms max.
12 ms max.
12 ms max.
1
.1
10,000
CURVE 2 AC VOLTAGE 50/60 Hz.
OVERLOAD TRIP TIMES
(SEC.)
1000
125%
200%
400%
600%
800%
1000%
100
10
10 - 150
2.2 - 20
.2 - 2
.03 - .75
.007 - .15
.005 - .04
1
.1
10
1
.01
.01
.001
0
TIME IN SECONDS
1000
100
10
1
.1
10,000
125%
200%
400%
600%
800%
1000%
100
10
10 - 150
3 - 25
.5 - 2.5
.15 - 1
.015 - .7
.009 - .35
1
.1
.001
0
CURVE 13 HIGH INRUSH 50/60 Hz.
OVERLOAD TRIP TIMES
(SEC.)
1000
125%
200%
400%
600%
800%
1000%
100
10
.8 - 30
.15 - 2.5
.03 - .3
.02 - .15
.009 - .12
.009 - .09
1
.1
.01
.01
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
10,000
OVERLOAD TRIP TIMES
(SEC.)
1000
.01
.001
0
CURVE 12 HIGH INRUSH 50/60 Hz.
TIME IN SECONDS
OVERLOAD TRIP TIMES
(SEC.)
125%
40 - 500
200%
9 - 100
400%
2 - 20
600%
.8 - 10
800%
.1 - 4.5
1000%
.009 - 2
TIME IN SECONDS
MOTOR START
CURVE 10 HIGH INRUSH 50/60 Hz. AC
1 - 15
.15 - 1.5
.03 - .25
.007 - .15
.003 - .08
.003 - .04
.1
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
125%
200%
400%
600%
800%
1000%
100
.01
10,000
OVERLOAD TRIPTIMES
(SEC.)
1000
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
CURVE 3 AC VOLTAGE 50/60 Hz.
10,000
TIME IN SECONDS
TRIP TIMES
OVERLOAD @ 50/60 Hz. & DC @ 400 Hz.
1000
TIME IN SECONDS
CURVE 0 NON-TIME DELAY
TIME IN SECONDS
400 Hz.
10,000
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
DC
125%
200%
400%
600%
800%
1000%
100
10
1
2 - 55
.60 - 8
.1 - 1.5
.02 - .5
.004 - .05
.004 - .025
.1
OVERLOAD TRIP TIMES
(SEC.)
1000
TIME IN SECONDS
TIME IN SECONDS
1000
CURVE 3 DC VOLTAGE
10,000
OVERLOAD TRIP TIMES
(SEC.)
125%
200%
400%
600%
800%
1000%
100
10
1
.6 - 7
.16 - 1.5
.03 - .25
.01 - .13
.004 - .05
.003 - .015
.1
100
10
1
.1
.01
.01
.001
0
.001
0
.001
0
AC/DC
100
10
OVERLOAD TRIP TIMES
(SEC.)
135%
200%
400%
600%
800%
1000%
1 - 90
.60 - 20
.095 - 2
.02 - .95
.002 - .45
.002 - .09
1
.1
10,000
1000
CURVE 2 AC VOLTAGE 400 Hz.
OVERLOAD TRIP TIMES
(SEC.)
150%
200%
400%
600%
800%
1000%
100
10
1
5 - 60
2.2 - 20
.3 - 3.2
.01 - .17
.006 - .06
.005 - .045
.1
150%
200%
400%
600%
800%
1000%
100
10
1
.01
.01
.001
0
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
Note:
For instantaneous curves for all voltages refer to Curve 0 Non-Time Delay under the AC 50/60 Hz. heading.
Pulse Tolerance Specifications
Pulse tolerance is defined as a single pulse of a half sine
wave (1/2 cycle or 8 milliseconds) that will not trip the
breaker. An inertia wheel for increased pulse tolerance is
available by specifying “P” after the time delay curve
number in the ordering information. The table at right lists
pulse tolerance values of standard and inertia delay models.
Voltage
AC
50/60 Hz.
AC
400 Hz.
.55 - 5.5
.18 - 2
.02 - .2
.006 - .075
.004 - .05
.004 - .035
.1
.01
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
OVERLOAD TRIP TIMES
(SEC.)
1000
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
135
OF BREAKER RATING
CURVE 3 AC VOLTAGE 400 Hz.
10,000
TIME IN SECONDS
TIME IN SECONDS
1000
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
AC 400 Hz.
CURVE 34 DC, 50/60 Hz. STANDARD DELAY
TIME IN SECONDS
10,000
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
OVERLOAD TRIP TIMES
(SEC.)
125%
80 - 700
200%
15 - 150
400%
2 - 20
600%
.70 - 10
800%
.10 - 3
1000%
.01 - .1
1000
.01
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
CURVE 53 DC HIGH INRUSH
10,000
TIME IN SECONDS
CURVE 2 DC VOLTAGE
10,000
Pulse Tolerance Value
Time
Delay
Curve
Standard
Inertia
Delay
2
3
10
12
13
7.5
6
18
18
18
18
18
30
30
30
2
3
6.5
5.5
18
18
To determine pulse tolerance multiply breaker rating by value in table. For
example, a 2A breaker with time delay curve 3 has a standard pulse tolerance
of 12A (2A x 6). The same breaker with an inertia delay has a pulse tolerance
of 36A (2A x 18).
Ordering Information
W6 Series
Typical Part No.
B
W 67- X
2
Q
2- 20
1
1. Circuit Breaker Mounting:
W = #6-32 mounting threads.
M = M3.0 x 0.5 mounting threads.
X = Snap-in mounting. (Not available in rocker actuated models.)
2. Number of Poles:
67 = Single pole
68 = Two pole
69 = Three pole
3. Circuit Function: (Only X is VDE approved)
A = Series trip with auxiliary switch (.093” QC)
4. Actuator: (One actuator per pole)
1 = Black toggle
3 = Black rocker
2 = White toggle
4 = White rocker
70 = Four pole
X = Series trip
5 = Red rocker
6 = Grey rocker
9 = Red toggle
5. Termination:
Q = .250” QC (DIN 46 244) 25A Max. VDE
S = #8-32 screw
T = #10-32 screw
Note: “T” termination must be used for all ratings of 31 amps or above.
6. Maximum Line Voltage: (See Table 1 for current ranges)
UL/CSA 1 = 277VAC, 50/60 Hz.
VDE
TYPES
2 = 277/480
TYPES
3 = 250VAC, 400 Hz.
5 = 65VDC
7 = AC/DC 277VAC or 65VDC
(Delay curve 34 must be specified.)
7. Time Delay Curve:
0 = Instantaneous
2 = Standard delay
3 = Short delay
53 = DC high inrush
8. Amp Rating:
0.20
0.50
0.25
0.75
1 = 250VAC, 415/240VAC
5 = 65VDC
7 = AC/DC 250VAC, 415/240VAC, 65VDC
(Delay curve 34 must be specified.)
10 = AC high inrush (Motor start)
12 = AC high inrush version of #2
13 = AC high inrush version of #3
34 = Combination AC/DC standard delay
1.0
1.5
2.0
2.5
3.0
3.5
4.0
5.0
6.0
7.0
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle by
adding "P" after curve, See delay curve section for availability and details.
7.5
8.0
9.0
10.0
9. VDE Approval: (See Table 2 for auxiliary switch ratings)
Blank = UL/CSA approved breaker
V = VDE approved breaker without auxiliary switch
V1 = VDE approved breaker with 10 amp VDE auxiliary switch
11.0
12.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
Consult factory for
other values.
V2 = VDE approved breaker with 5 amp VDE auxiliary switch
V3 = VDE approved breaker with 0.1 amp VDE auxiliary switch
Stock Items - We recommend that our authorized distributors stock the following items for immediate delivery.
W67-A2Q12-5
W67-A2Q12-10
W67-X2Q10-3
W67-X2Q10-5
W67-X2Q12-2
W67-X2Q12-3
W67-X2Q12-5
W67-X2Q12-7
W67-X2Q12-10
W67-X2Q12-15
W67-X2Q12-20
W67-X2Q12-30
W67-X2Q13-1
W67-X2Q13-2
W67-X2Q13-3
W67-X2Q13-10
W67-X2Q13-15
W67-X2Q13-20
W67-X2Q13-25
W67-X2Q13-30
W67-X2Q50-5
W67-X2Q50-10
W67-X2Q52-5
W67-X2Q52-10
W67-X2Q52-15
W67-X2Q52-20
W67-X2Q52-30
W67-X2Q110-15
W67-X2Q110-20
W68-X2Q12-3
W68-X2Q12-5
W68-X2Q12-7
W68-X2Q12-10
W68-X2Q12-15
W68-X2Q12-20
W68-X2Q12-25
W68-X2Q12-30
W68-X2Q13-15
W68-X2Q110-10
W68-X2Q110-20
W69-X2Q12-5
W69-X2Q12-10
W69-X2Q12-15
W69-X2Q12-20
W69-X2Q12-25
W69-X2Q12-30
W69-X2Q110-20
W69-X2Q110-30
Ordering Information
W9 Series
Typical Part No.
1. Circuit Breaker Mounting:
W = #6-32 mounting threads.
2. Number of Poles:
91 = Single pole
B
W
91- X
1
1
2-
20
M = M3.0 x 0.5 mounting threads.
92 = Two pole
93 = Three pole
3. Circuit Function: (Only X is VDE approved)
A = Series trip with auxiliary switch (.093” QC)
94 = Four pole
X = Series trip
4. Actuator: (One actuator per pole):
1 = Black toggle
2 = White toggle
5. Maximum Line Voltage: (See Table 1 for current ranges)
UL/CSA 1 = 277VAC, 50/60 Hz.
VDE
1 = 250VAC, 415/240VAC
TYPES
2 = 277/480
TYPES 5 = 65VDC
3 = 250VAC, 400 Hz.
7 = AC/DC 250VAC, 415/240VAC, 65VDC
5 = 65VDC
(Delay curve 34 must be specified.)
7 = AC/DC 277VAC or 65VDC
(Delay curve 34 must be specified.)
6. Time Delay Curve:
0 = Instantaneous
2 = Standard delay
3 = Short delay
53 = DC high inrush
7. Amp Rating:
0.20
0.75
0.25
1.0
0.50
1.5
10 = AC high inrush (Motor start)
12 = AC high inrush version of #2
13 = AC high inrush version of #3
34 = Combination AC/DC standard delay
2.0
2.5
3.0
3.5
4.0
5.0
6.0
7.0
7.5
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle
by adding "P" after curve. See delay curve section for availability and details.
8.0
9.0
10.0
8. VDE Approval: (See Table 2 for auxiliary switch ratings)
Blank = UL/CSA approved breaker
V = VDE approved breaker without auxiliary switch
V1 = VDE approved breaker with 10 amp VDE auxiliary switch
11.0
12.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
Consult factory for other values
V2 = VDE approved breaker with 5 amp VDE auxiliary switch
V3 = VDE approved breaker with 0.1 amp VDE auxiliary switch
Stock Items - We recommend that our authorized distributors stock the following items for immediate delivery.
W91-X112-1
W91-X112-2
W91-X112-3
W91-X112-5
W91-X112-7
W91-X112-10
W91-X112-15
W91-X112-20
W91-X112-40
W91-X112-50
W91-X113-5
W91-X113-10
W91-X113-15
W91-X150-5
W91-X152-10
W91-X152-15
W91-X152-20
W91-X152-30
W91-X152-40
W91-X152-50
W91-X1110-20
W92-X112-1
W92-X112-2
W92-X112-3
W92-X112-5
W92-X112-7
W92-X112-10
W92-X112-15
W92-X112-20
W92-X112-25
W92-X112-30
W92-X112-40
W92-X112-50
W92-X113-15
W92-X113-20
W92-X1110-20
W92-X1110-30
W93-X112-5
W93-X112-10
W93-X112-15
W93-X112-20
W93-X112-25
W93-X112-30
W93-X112-40
W93-X112-50
W93-X1110-20
W93-X1110-30
Outline Dimensions - Toggle Actuator Models.
W6 Series
Panel Mounting Cutout
1.640
(41.66)
.235
(5.97)
LINE
.245
(6.22)
O
N
A
1.530
(38.86)
.750
(19.05)
Ø .625 +.010
-.000
15.88 +0.25
-0.00
1 PER POLE
(
29°
)
1.660
(42.16)
30°
1.048
(26.62)
OFF
B
LOAD
2.040
(51.82)
Ø .156
(3.96)
[2 PLACES PER POLE]
.67
(17.02)
W6 Series
1 Pole
2 Pole
3 Pole
4 Pole
Ø .590
(15.00)
1.500
(38.10)
.750
(19.05)
2.000
(50.80)
1.22
(31.00)
2.250
(57.15)
3.000
(76.20)
1.660
(42.16)
1.05
(26.67)
6.32 TH'D. .14 (3.56) DP. TYP.
M3 X 0.5 OPTIONAL
Note:
Multi-pole models furnished
with separate handle tie hardware.
VDE Models
W/Screw Terminals
UL/CSA Models
W/Screw Terminals
.235
(5.9)
LINE
2.032
(51.61)
UL/CSA/VDE Models
W/Aux. Switch
2.38 “A” STYLE
(60.45)
.416
(10.57)
LINE
LINE
1.530
(38.86)
.827
(20.85)
1.058
(26.87)
C
NO
NC
LOAD
LOAD
Notes:
1. Terminal protrusion dimensions are referenced from back of mounting panel.
2. Main terminals are male quick connect type .250 (6.35) wide x .031 (.79)
thick x .377 (9.58) long. Optional 8-32 x .250 (6.35) or 10-32 x .250 (6.35)
screw type.
3. Panel mounting cutout detail mtg. detail tol.: ± .005 (.13) unless noted. Add
additional cutouts to correspond to number of poles. Outline drawing
tolerance ± .015 (.38) unless noted. Dimensions in brackets ( ) are in millimeters.
LOAD
Outline Dimensions - Rocker Actuator Models
W6 Series
1 Pole
3.000
(76.20)
2.250
(57.15)
.750
(19.05)
.390
(9.91)
1.500
(38.10)
2 POLE
.375
(9.53)
.180
(4.57)
LOAD
2, 3 & 4 Pole
.805
(20.45)
1.640
(41.66)
D
1.530
(38.86)
2.000
(50.80)
1.30
(33.0) 1.660
(42.16)
.388
(9.86)
ON
2.600
(66.04)
OFF
A
LINE
.235
(5.97)
2.430
(61.72)
4 POLE
ON
OFF
.750
(19.05)
.750
(19.05)
.750
(19.05)
.375
(9.53)
2.000
(50.80)
.388
(9.86)
I
2.600
(66.04)
O
3 POLE
ON
OFF
.750
(19.05)
.205
(5.21)
.750
(19.05)
1.250
(31.75)
1.660
(42.16)
2 POLE
ON
OFF
VDE Rocker Marking
.750
(19.05)
.750
(19.05)
.375
(9.53)
ON
OFF
.375
(9.53)
TAPPED FOR #6-32
M3 X 0.5 OPTIONAL
Panel Mounting Cutout
1 POLE
4
POLE
3
POLE
.750
(19.05)
1.500
(38.10)
2.250
(57.15)
3.000
(76.20)
Ø .156
(3.96)
TYP. 2
PER POLE
Notes:
1. Outline drawing tolerance ± .015 (.38) unless
noted. Dimensions in brackets ( ) are in
millimeters.
2. Mounting Detail Tol.: ± .005 (.13) unless noted
TAPPED FOR #6-32
M3 X 0.5 OPTIONAL
Outline Dimensions - Snap-in Mounted Models
W6 Series
1 Pole
1.640
(41.66)
.235
(5.97)
.245
(6.22)
.128
(3.25)
.750
(19.05)
O
N
ON
29°
1.530
(38.86)
2 Pole
3 Pole
2.250
(57.15)
1.500
(38.10)
1.110
(28.19)
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
2.650
(67.31)
30°
OFF
OFF
2.040
(51.82)
.67
(17.02)
4 Pole
Panel Mounting Cutout
1 Pole
2 Pole
.770
(19.6)
1.525
(38.7)
3 Pole
2.280
(57.9)
3.000
(76.20)
3.040
(77.2)
ON
ON
ON
ON
OFF
OFF
OFF
OFF
2.187
(55.55)
Notes:
Mounting Detail Tol.: ± .005 (.13) unless noted
Panel Thickness: .047 (1.2) to .110 (2.8)
Outline Dimensions
W9 Series
Series Trip Model
Series Trip Model
.750
(19.05)
1.845
(46.86)
.281
(7.14)
LINE
.313
(7.95)
.375
(9.53)
ON
ON ON
29°
1.940
(49.28)
30°
OFF OFF
.750
(19.05)
.375
(9.53)
.218
(5.54)
2.065
(52.45)
OFF
.750
(19.05)
.750
(19.05)
.398
(10.77)
ON ON ON ON ON ON ON ON
1.438
(36.53)
2.50
OFF OFF OFF OFF OFF OFF OFF OFF
(63.5)
LOAD
.14
2.10 (3.56)
(53.34)
2.50
(64.00)
#10-32
STUD TERMINATION
Series Trip Model
With Common Enclosed Auxiliary Switch
2.46
(62.48) 'A' STYLE
.281
(7.14)
2 POLE
1.500
(38.10) 2.250
3POLE
(57.15) 3.000
(76.20)
1 POLE
.74
(18.8)
TAPPED #6-32 X .16 (4.06)
DEEP
M3 X 0.5 OPTIONAL
Panel Mounting Cutout Detail
.750
(19.05)
.732
(18.59)
.750
(19.05)
.750
(19.05)
.385
(9.78)
.907
(23.04)
LINE
1.940
(49.28)
1.450
(36.83)
C
NO
2.065
(52.45)
NC
LOAD
2.50
(64.00)
4 POLE
2X Ø .156
(3.96)
PER POLE
3.04
(77.2)
2.28
(57.9)
.76
(19.3)
1.52
(38.6)
Notes:
1. Terminal protrusion
dimensions are referenced
from the back of the
mounting panel.
2. Mounting detail tolerance
±.005 (13) unless noted.
3. Outline drawing tolerance ±
.015 (.38) unless noted.
Dimensions in brackets ( )
are in millimeters.
1 POLE
2 POLE
3 POLE
4 POLE
Tyco Electronics
700 Westpark Drive
Peachtree City, GA 30269-1498
Specifications and availability subject to change without notice.
13C9699
Printed in U.S.A.
IH/2-00