SCHURTER 4303.1091

KEC
Power entry modules without line filter
www.schurter.com/pg05
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole and Voltage Selector
Fuse drawer must be ordered separately (see
accessories).
Standard or Medical Fuse drawer
Fuse drawer must be ordered separately (see
accessories).
C14
70° C
Description
-Panel Mount:
Screw-on version from front or rear side, snap-in version from front
side
-3 Functions:
Appliance Inlet Protection class I, Fuseholder with interchangeable fuse
drawer for Fuse-links 5 x 20 mm or 6.3 x 32 mm 1‑ or 2‑pole, with or
without voltage selector (step switch)
-Quick connect terminals 4.8 x 0.8 mm
-Alternative: version with line filter KFC Approvals
Characteristics
-Available with or without internal connections
-The fuse drawer "Fingergrip" can be removed by hand
For added safety "Extra-Safe" fuse drawers are available
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuse drawer can only be opened with the aid of a tool
The fuseholder is accessible from the equipment front
-Qualified for use in equipment according IEC/EN 60950
Other versions on request
-Fuse drawer with other voltage values
-For protection class II
References
-VDE License Number: 40012271
-UL License Number: E93617
-CSA License Number: 38456
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
10 A / 250 VAC; 50 Hz
13 A / 125 VAC; 60 Hz ¹⁾
> 3 kVAC between L-N
> 4 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 4.8 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1.5/2/2.5 mm
Thermoplastic, black, UL 94V-0
Appliance Inlet
Fuseholder
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Voltage Selectors
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 or 6.3 x 32 mm
5 x 20: 2.5 W (1 pole)/ 2 W (2-pole) per
pole
6.3 x 32: 3.15 W (1 pole)/ 2.5 W (2-pole)
per pole
Admissible power acceptance at higher ambient temperature see derating
curves
optional, step, 2-4 digits
1) UL/CSA: 1-pole version 13 A, 2-pole version 10 A
Dimensions
Screw on PCB mounting
58 mm
Snap-in mounting
55
R 4.5
4.8x0.8
S ±0.1
0
R 3 -0.2
R 3.1
27.2
R 3 -0.2
18
27.5
2
2.2
18
27.5
41
40.7
+0.2
0
230
0
43.5
41
40.7
58
50
+0.2
0
ø 6.3x90˚
ø 3.2
4.8x0.8
30
230
R 4.5
55
M3/ø 3.6
R6
50 ±0.15
30
27.2
+0.2
0
R 3.1
27.5
Connectors
2
2.2
27.5
+0.2
0
KEC
Power entry modules without line filter
www.schurter.com/pg05
Diagrams
without internal connections
Voltage selector
4-positions, 1-pole
without internal connections
Voltage selector
4-positions, 2-pole
with internal connections
Voltage selector
4-positions, 1-pole
with internal connections
Voltage selector
4-positions, 2-pole
Voltage selector
3-positions
1-pole
Voltage selector
3-positions
2-pole
Voltage selector
2-positions
1-pole
Voltage selector
2-positions
2-pole
without voltage selector
1-pole
without voltage selector
2-pole
Derating Curves
Fuses
5 x 20 mm (1-pole)
Fuses
5 x 20 mm (2-pole, per pole)
2.0
2.0
I = 1.0 In
1.5
I = 0.7 In
I = < < In
1.0
0.5
0.0
0
20
40
60
80
100
Admissible power acceptance in
Watt per pole
Admissible power acceptance in
Watt
2.5
Ambient air temperature Ta °C
I = 0.7 In
1.0
I = < < In
0.5
0.0
0
20
40
60
80
100
40
60
80
100
Fuses
6.3 x 32 mm (2-pole, per pole)
3.15
2.5
2.5
I = 1.0 In
2.0
I = 0.7 In
1.5
I = << In
1.0
0.5
0.0
0
20
40
60
80
100
Admissible power acceptance in
Watt per pole
Admissible power acceptance in
Watt
I = 1.0 In
Ambient air temperature Ta °C
Fuses
6.3 x 32 mm (1-pole)
Ambient air temperature Ta °C
1.5
2.0
I = 1.0 In
1.5
I = 0.7 In
I = < < In
1.0
0.5
0.0
0
20
Ambient air temperature Ta °C
Connectors
KEC
Power entry modules without line filter
www.schurter.com/pg05
Variants
Fuse drawer must be ordered separately (see accessories).
Fingergrip and Extra-Safe
Panel mounting
Panel Thickness
s [mm]
Fuseholder
Voltage Selectors
Internally wired
Screw
-
Screw
-
Screw
1-pole
without
l
4303.0031
1-pole
3/4 digits
l
4303.0091
-
1-pole
2 pos.
l
4303.0211
Screw
-
1-pole
without
4303.1031
Screw
-
1-pole
3/4 digits
4303.1091
Screw
-
1-pole
2 pos.
Screw
-
2-pole
without
l
4303.0001
Screw
-
2-pole
3/4 digits
l
4303.0061
Screw
-
2-pole
2 pos.
l
4303.0181
Screw
-
2-pole
without
4303.1001
Screw
-
2-pole
3/4 digits
4303.1061
Screw
-
2-pole
2 pos.
Snap-in
1.5
1-pole
without
l
4303.0032
Snap-in
1.5
1-pole
3/4 digits
l
4303.0092
Snap-in
1.5
1-pole
2 pos.
l
4303.0212
Snap-in
2
1-pole
without
l
4303.0033
Snap-in
2
1-pole
3/4 digits
l
4303.0093
Snap-in
2
1-pole
2 pos.
l
4303.0213
Snap-in
2.5
1-pole
without
l
4303.0034
Snap-in
2.5
1-pole
3/4 digits
l
4303.0094
Snap-in
2.5
1-pole
2 pos.
l
4303.0214
Snap-in
1.5
1-pole
without
4303.1032
Snap-in
1.5
1-pole
3/4 digits
4303.1092
Snap-in
1.5
1-pole
2 pos.
4303.1212
Snap-in
2
1-pole
without
4303.1033
Snap-in
2
1-pole
3/4 digits
4303.1093
Snap-in
2
1-pole
2 pos.
4303.1213
Snap-in
2.5
1-pole
without
4303.1034
Snap-in
2.5
1-pole
3/4 digits
4303.1094
Snap-in
2.5
1-pole
2 pos.
Snap-in
1.5
2-pole
without
l
4303.0002
Snap-in
1.5
2-pole
3/4 digits
l
4303.0062
Snap-in
1.5
2-pole
2 pos.
l
4303.0182
Snap-in
2
2-pole
without
l
4303.0003
Snap-in
2
2-pole
3/4 digits
l
4303.0063
Snap-in
2
2-pole
2 pos.
l
4303.0183
Snap-in
2.5
2-pole
without
l
4303.0004
Snap-in
2.5
2-pole
3/4 digits
l
4303.0064
Snap-in
2.5
2-pole
2 pos.
l
4303.0184
Snap-in
1.5
2-pole
without
4303.1002
Snap-in
1.5
2-pole
3/4 digits
4303.1062
Snap-in
1.5
2-pole
2 pos.
4303.1182
Snap-in
2
2-pole
without
4303.1003
Snap-in
2
2-pole
3/4 digits
4303.1063
Snap-in
2
2-pole
2 pos.
4303.1183
Snap-in
2.5
2-pole
without
4303.1004
Snap-in
2.5
2-pole
3/4 digits
4303.1064
Snap-in
2.5
2-pole
2 pos.
4303.1184
Packaging unit Order Number
4303.1211
4303.1181
4303.1214
50 Pcs Connectors
KEC
Power entry modules without line filter
www.schurter.com/pg05
Required Accessory
Description
Fusedrawer 3
Fusedrawer for Fuse Links 5x20mm resp.. 6.3x32mm
Fingergrip, 5 x 20, 2-pole, Voltage Selectors
4303.2014.00
Fingergrip, 5 x 20, 2-pole, Voltage Selectors, 100, 120, 220, 240
4303.2014.01
Fingergrip, 5 x 20, 2-pole, Voltage Selectors, 110, 150, 220
4303.2014.02
Fingergrip, 5 x 20, 2-pole, Voltage Selectors, 110, 220
4303.2014.03
...
Accessories
Assorted Covers
Rear Cover
0859.0072
Cord retaining kits
Cord retaining strain relief
Flat head, A
4700.0001
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
5092
Appliance Outlet further types to KEC
Connector Overview complete
IEC Connector C15, Rewireable, Straight
0101
IEC Connector C15A, Rewireable, Straight
0102
IEC Connector C15A, Rewireable, Straight
0102-G
IEC Connector C15A, Rewireable, Angled
0112
IEC Connector C13, Rewireable, Angled
4012
Connector further types to KEC
...
Power Cord Overview complete
Power Cord with IEC Connector C13, Angled
0311
Power Cord with IEC Connector C13, Angled
3011
Power Cord with IEC Connector C13, Angled
3012
Power Cord with IEC Connector C13, Angled
3013
Power Cord with IEC Connector C13
3020
Power Cord further types to KEC
...
The
specifications, descriptions and illustrations indicated in this document are based on
Connectors