SCHURTER KD13.4101.109

KD
Power entry modules without line filter
www.schurter.com/pg05
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole, Line Switch 1- or 2-pole and Voltage Selector
Standard or Medical Fuse drawer
C14
70° C
Description
Characteristics
-Panel Mount:
Screw-on version from front or rear side, snap-in version from front
side
-4 Functions:
Appliance Inlet Protection class I, Line Switch 1‑ or 2‑pole, Fuseholder with interchangeable fuse drawer for Fuse-links 5 x 20 mm or
6.3 x 32 mm, with or without voltage selector (step)
-Quick connect terminals 4.8 x 0.8 mm
-Alternative: version with line filter CD -All single elements are already wired
-The fuse drawer "Fingergrip" can be removed by hand
For added safety "Extra-Safe" fuse drawers are available
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuse drawer can only be opened with the aid of a tool
The fuseholder is accessible from the equipment front
-Qualified for use in equipment according IEC/EN 60950
Other versions on request
-Line switch, illuminated -Line switch with other rocker marking
-Line switch 1-pole
-For protection class II
Approvals
-VDE License Number: 40011925
-UL License Number: E93617
-CSA License Number: 38456
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
10 A / 250 VAC; 50 Hz
10 A / 125 VAC; 60 Hz
> 3 kVAC between L-N
> 4 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 4.8 x 0.8 mm
, tin-plated
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1.5/2/2.5 mm
Thermoplastic, black, UL 94V-0
Appliance Inlet
Fuseholder
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Voltage Selectors
Connectors
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 or 6.3 x 32 mm
5 x 20: 2.5 W (1 pole)/ 2 W (2-pole) per
pole
6.3 x 32: 3.15 W (1 pole)/ 2.5 W (2-pole)
per pole
Admissible power acceptance at higher ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
optional, step, 2-4 digits
KD
Power entry modules without line filter
www.schurter.com/pg05
Dimensions
Screw on PCB mounting
55
30
M3/ø 3.6
R6
R 4.5
S ±0.1
4.8x0.8
66.5 0
+0.2
230
69
75.5 ±0.15
+0.2
66.5 0
66.2
83.5
75.5
230
ø 6.3x90˚
ø 3.2
4.8x0.8
55
66.2
30
R 4.5
83.5 mm
Snap-in mounting
0
0
R 3 -0.2
R 3 -0.2
18
R 3.1
2
2.2
27.5
27.2
18
R 3.1
+0.2
27.5 0
2
2.2
27.5
27.2
27.5
Diagrams
without voltage selector
without voltage selector
with voltage selector
with voltage selector
1-pole
2-pole
1-pole
2-pole
Derating Curves
Fuses
5 x 20 mm (1-pole)
Fuses
5 x 20 mm (2-pole, per pole)
2.0
2.0
I = 1.0 In
1.5
I = 0.7 In
I = < < In
1.0
0.5
0.0
0
20
40
60
80
100
Admissible power acceptance in
Watt per pole
Admissible power acceptance in
Watt
2.5
Ambient air temperature Ta °C
I = 0.7 In
1.0
I = < < In
0.5
0.0
0
20
40
60
80
100
40
60
80
100
Fuses
6.3 x 32 mm (2-pole, per pole)
3.15
2.5
2.5
I = 1.0 In
2.0
I = 0.7 In
1.5
I = << In
1.0
0.5
0.0
0
20
40
60
80
100
Admissible power acceptance in
Watt per pole
Admissible power acceptance in
Watt
I = 1.0 In
Ambient air temperature Ta °C
Fuses
6.3 x 32 mm (1-pole)
Ambient air temperature Ta °C
1.5
2.0
I = 1.0 In
1.5
I = 0.7 In
I = < < In
1.0
0.5
0.0
0
20
Ambient air temperature Ta °C
Connectors
+0.2
0
KD
Power entry modules without line filter
www.schurter.com/pg05
Fuse drawer must be ordered separately
Type
Panel mounting
Panel Thickness
s [mm]
Fuseholder
Line Switch
Voltage selector max.
4 pos*
Order Number
KD
Screw
-
1-pole
Rocker switch
2-4 digits
KD13.4101.151
KD
Screw
-
1-pole
Rocker switch
without
KD13.1101.151
KD
Screw
-
2-pole
Rocker switch
2-4 digits
KD14.4101.151
KD
Screw
-
2-pole
Rocker switch
without
KD14.1101.151
KD
Snap-in
1.5
1-pole
Rocker switch
2-4 digits
KD13.4101.105
KD
Snap-in
2
1-pole
Rocker switch
2-4 digits
KD13.4101.107
KD
Snap-in
2.5
1-pole
Rocker switch
2-4 digits
KD13.4101.109
KD
Snap-in
1.5
1-pole
Rocker switch
without
KD13.1101.105
KD
Snap-in
2
1-pole
Rocker switch
without
KD13.1101.107
KD
Snap-in
2.5
1-pole
Rocker switch
without
KD13.1101.109
KD
Snap-in
1.5
2-pole
Rocker switch
2-4 digits
KD14.4101.105
KD
Snap-in
2
2-pole
Rocker switch
2-4 digits
KD14.4101.107
KD
Snap-in
2.5
2-pole
Rocker switch
2-4 digits
KD14.4101.109
KD
Snap-in
1.5
2-pole
Rocker switch
without
KD14.1101.105
KD
Snap-in
2
2-pole
Rocker switch
without
KD14.1101.107
KD
Snap-in
2.5
2-pole
Rocker switch
without
KD14.1101.109
Can be used as 2-/3-position voltage selector - take only corresponding terminals
Packaging unit 20 Pcs Required Accessory
Description
Fusedrawer 3
Fusedrawer for Fuse Links 5x20mm resp.. 6.3x32mm
Fingergrip, 5 x 20, 2-pole, Voltage Selectors
4303.2014.00
Fingergrip, 5 x 20, 2-pole, Voltage Selectors, 100, 120, 220, 240
4303.2014.01
Fingergrip, 5 x 20, 2-pole, Voltage Selectors, 110, 150, 220
4303.2014.02
Fingergrip, 5 x 20, 2-pole, Voltage Selectors, 110, 220
4303.2014.03
...
Accessories
Assorted Covers
Rear Cover
0859.0074
Cord retaining kits
Cord retaining strain relief
Flat head, A
4700.0001
Connectors
KD
Power entry modules without line filter
www.schurter.com/pg05
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
5092
Appliance Outlet further types to KD
Connector Overview complete
IEC Connector C15, Rewireable, Straight
0101
IEC Connector C15A, Rewireable, Straight
0102
IEC Connector C15A, Rewireable, Straight
0102-G
IEC Connector C15A, Rewireable, Angled
0112
IEC Connector C13, Rewireable, Angled
4012
Connector further types to KD
...
Power Cord Overview complete
Power Cord with IEC Connector C13, Angled
0311
Power Cord with IEC Connector C13, Angled
3011
Power Cord with IEC Connector C13, Angled
3012
Power Cord with IEC Connector C13, Angled
3013
Power Cord with IEC Connector C13
3020
Power Cord further types to KD
...
The
specifications, descriptions and illustrations indicated in this document are based on
Connectors
current information. All content is subject to modifications and amendments.