FUJIKURA XFGN

XFGN Data sheet
Pre-amplified/5V Excitation/Gauge
■Features
On-chip amplification and temperature compensations
Pre-calibration of offset voltage and span
Surface mount package
■Ordering Information
XFGN-6 025KP G SR
Terminal leads configuration
Model
Surface mount package
Length of the pressure port
6:6mm
Rated Pressure
(kPa)
Weight
(grams)
Pressure type
G:Gauge(Positive pressure)
GV:Gauge Pressure(Negative pressure)
RoHS compliance
0.35
Measurable pressure
range(kPa)
0 to -24.5
XFGN-603PGVSR
0 to -100
XFGN-6100KPGVSR
0 to 25
XFGN-6025KPGSR
Part number
0 to 50
XFGN-6050KPGSR
0 to 100
XFGN-6100KPGSR
0 to 200
XFGN-6200KPGSR
■Specifications
Model
603PGV
Recommended operating conditions
Pressure type
Rated pressure
Measurable pressure range
Temperature range
Pressure media
Excitation current (Constant)
-24.5
0 to -24.5
6100KPGV
6025KPG
6050KPG
6100KPG
6200KPG
Gauge pressure
25
50
100
0 to 25
0 to 50
0 to 100
0 to 50
Non-corrosive gases only (No liquid)
5+/-0.25
-100
0 to -100
200
0 to 200
Unit
kPa
kPa
deg.C
VDC
Absolute maximum rating
Twice of rated pressure
8
-10 to 80
-20 to 100
30 to 80 (Non dew condition)
Electrical characteristics (Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25deg.C)
Power consumption
10mA max.
Output impedance
10Ω max.
Source current
0.2mA max.
Sink current
2mA max.
Response time
2 (for the reference)
Output span voltage
4.0
0.5V(at 0kPa)
Offset voltage *
+/-0.1V(25deg.C) , +/-0.2V(0 to 50deg.C)
4.5V(at rated pressure)
Output voltage at full scale *
+/-0.1V(25deg.C) , +/-0.2V(0 to 50deg.C)
Accuracy *
+/-5.0
Maximum load pressure
Maximum excitation voltage
Operating temperature
Storage temperature
Operating humidity
* Excluding input voltage error.
1
VDC
deg.C
deg.C
%RH
mA
Ω
mA
mA
msec.
V
V
V
%FS/0-50deg.C
XFGN Data sheet
Pre-amplified/5V Excitation/Gauge
■Outline dimensions■
XFGN
2-φ1.1
■Connection diagram■
View from Lavel
Marking
2
XFGN Data sheet
Pre-amplified/5V Excitation/Gauge
■Transfer Function■
Vout = Vs×( P×α+β) ± (Pressure Error×Temperature Error Multiplier×α×Vs)
Vs=Vcc=5.0V
P=Input pressure(kPa)
Measurable
pressure
range(kPa)
0 to -24.5
0 to -100
0 to 25
0 to 50
0 to 100
0 to 200
Model
XFGN-603PGVSR
XFGN-6100KPGVSR
XFGN-6025KPGSR
XFGN-6050KPGSR
XFGN-6100KPGSR
XFGN-6200KPGSR
α
β
Pressure Error
(kPa)
-0.03266
-0.008
0.032
0.016
0.008
0.004
0.1
0.1
0.1
0.1
0.1
0.1
0.612
2.5
0.625
1.25
2.5
5
Temperature Error Multiplier
■Output characteristics■
↑Output voltage(mV)
Output voltage
at full scale
4.5V
Output span
voltage
Offset voltage
0.5V
Rated pressure
0kPa
Atomospheric
pressure
Note ;
→Pressure(kPa)
Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
Please keep the sensors sealed using static shielding bags on storage.The pins of the sensor are plated by Ag.
If the sensors expose to an atmosphere, the pins will be black by sulfuration.
Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress
such as mounting, installation and etc. over longtime using.
3
XFGN Data sheet
Pre-amplified/5V Excitation/Gauge
Reflow Soldering process recommendation profile
Package
Surface
Temperature
(Degree C)
230
210
150
Room
Temp.
Time
a
a: Rump up rate
b: Pre-heating
c: Rump up rate
d: Heating
e: Rump down rate
Note ;
b
c
d
e
1 or 2 deg.C/sec.
150 to 180 deg.C,within 60 to120sec.
1 to 2 deg.C/sec.
max.230 deg.C,max.10sec. 210 deg.C,within 30sec.
1 or 2 deg.C/sec.
1 ) Temperature means Surface temperature of the sensor package.
2 ) Reflow process max. 2 times.
3 ) Do not wash the sensor.
4 ) Do not put the solder and flux on the sensor package.
If you have any questions regarding technical issues or specifications, please contact us.
Fujikura Ltd. Sensor Department
5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072
E-mail : [email protected]
4