XFPN,XFGN-6 Data sheet

XFPN,XFGN-6 Data sheet
Pre-amplified/5V Excitation/Gauge
Features
.
.
.
.
Applications
. Non-Invasive Blood Pressure(NIBP)monitor for home health care
. Vacuum cleaner
. Washing machine
Volt level output
On-chip amplification and temperature compensations
Pre-calibration of offset voltage and span
Surface mount package (XFGN)
Part number for ordering
XFGN - 6 025KP G S R
Model
XFPN
XFGN
Terminal leads direction (See Outline Diagram)
No mark :
Rated pressure (Pa)
Length of the pressure
port
(XFGN only)
Pressure type
6 : 6mm
G : Gauge (Positive pressure)
GV : Gauge (Negative pressure)
Pressure type
R
:
Terminal leads configuration
No mark : DIP (XFPN)
S : Surface mount package (XFGN)
Gauge pressure
XFPN
XFGN-6
Dual-In-line-Package (DIP)
Surface mount package,6mm pressure port
Model
Package configuration
Measurable pressure range (kPa)
0
24.5
0
100
0 25
0 50
0 100
0 200
XFPN-03KPGV
XFPN-100KPGV
XFPN-025KPG
XFPN-050KPG
XFPN-100KPG
XFPN-200KPG
Part number for ordering
XFPN-03KPGVR
XFPN-100KPGVR
XFPN-025KPGR
XFPN-050KPGR
XFPN-100KPGR
XFPN-200KPGR
XFGN-603KPGVSR
XFGN-6100KPGVSR
XFGN-6025KPGSR
XFGN-6050KPGSR
XFGN-6100KPGSR
XFGN-6200KPGSR
Specifications
Model/Rated pressure
03KPGV
100KPGV
025KPG
050KPG
100KPG
Recommended operating conditions
Pressure type
Gauge pressure
24.5
100
25
50
100
Rated pressure
0.255
1.020
0.255
1.020
1.020
Pressure media
Non-corrosive gas
Excitation voltage
5 0.25
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
Maximum excitation voltage
8
Operating temperature
10 80
Storage temperature
20 100
Operating humidity
30 80 (No dew condensation)
Electric performances/characteristics (Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25 )
Current consumption
less than 10
Output impedance
less than 10
Source current
less than 0.2
Sink current
less than 2
Mechanical response time
2 (For the reference)
Full scale span voltage
4.0
Offset voltage
0.5 0.1
Full scale span voltage
4.5 0.1
Accuracy
5.0
Note ;
Excluding input voltage error.
1
200KPG
Unit
200
2.040
kPa
kg/cm2
VDC
VDC
RH
mA
mA
mA
msec
V
V
V
FS/0 50
XFPN,XFGN-6 Data sheet
Pre-amplified/5V Excitation/Gauge
Outline dimensions
Unit : mm
XFPN
4
5
4.5
5
6
3
2
1
3
C0.5
3
2
4
0.6
Vent hole
R1.5
15.24(600mil)
14
1
Pressure port
0.8
max 15
2.2
0.5
6
8
5
0.2
4
12
Terminal leads
Labelled faceplate
6.8
2.8
Recommended footprint for PCB
6- 0.9(Diameter of through holes)
2.54 2.54
2.54 2.54
1.2
0.5
60
6- 1.8(Diameter of lands)
15.2
(Unit : mm)
Unit : mm
XFPN-R
4
0.2
8
0.8
Pressure port
2.2
0.5
3
14
R1.5
4
5
6
3 2
4.5
1
15.24(600mil)
5
max 15
6
4
5
12
C0.5
1
2
0.6
Vent hole
3
Terminal leads
Recommended footprint for PCB
2.54 2.54
6- 0.9(Diameter of through holes)
6- 1.8(Diameter of lands)
2.54 2.54
60
1.2
0.5
Labelled faceplate
2.8
6.8
15.2
2
(Unit : mm)
XFPN,XFGN-6 Data sheet
Pre-amplified/5V Excitation/Gauge
Outline dimensions
Unit : mm
XFPN-6
2.54 2.54
0.8
Pressure port
2
6
5
3
7
1
4
7
Vent hole
3
0.5
Projections
6
5
4
Recommended footprint for PCB
2-R0.5
1
Projections
2- 1(Holes for projections)
1.4
1.7
1
2
3
Land-pads
Labelled faceplate
6.2
10.3
2.54 2.54
0.8
MA
0.25
X.
15
3.5
9.5
6
Index
6.2
9.4
(Unit : mm)
Connection diagram
XFPN, XFGN-6
Vcc(DC5V)
Vcc
Vout
Vout
GND
C2
Remarks :
C1
GND
1) C1 : Connect 680pF capacitor within 2cm distance from
leads.
2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads.
3) 4 and 5 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or
each other.
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
3
E-mail : [email protected]