XFPN,XFGN-6 Data sheet Pre-amplified/5V Excitation/Gauge Features . . . . Applications . Non-Invasive Blood Pressure(NIBP)monitor for home health care . Vacuum cleaner . Washing machine Volt level output On-chip amplification and temperature compensations Pre-calibration of offset voltage and span Surface mount package (XFGN) Part number for ordering XFGN - 6 025KP G S R Model XFPN XFGN Terminal leads direction (See Outline Diagram) No mark : Rated pressure (Pa) Length of the pressure port (XFGN only) Pressure type 6 : 6mm G : Gauge (Positive pressure) GV : Gauge (Negative pressure) Pressure type R : Terminal leads configuration No mark : DIP (XFPN) S : Surface mount package (XFGN) Gauge pressure XFPN XFGN-6 Dual-In-line-Package (DIP) Surface mount package,6mm pressure port Model Package configuration Measurable pressure range (kPa) 0 24.5 0 100 0 25 0 50 0 100 0 200 XFPN-03KPGV XFPN-100KPGV XFPN-025KPG XFPN-050KPG XFPN-100KPG XFPN-200KPG Part number for ordering XFPN-03KPGVR XFPN-100KPGVR XFPN-025KPGR XFPN-050KPGR XFPN-100KPGR XFPN-200KPGR XFGN-603KPGVSR XFGN-6100KPGVSR XFGN-6025KPGSR XFGN-6050KPGSR XFGN-6100KPGSR XFGN-6200KPGSR Specifications Model/Rated pressure 03KPGV 100KPGV 025KPG 050KPG 100KPG Recommended operating conditions Pressure type Gauge pressure 24.5 100 25 50 100 Rated pressure 0.255 1.020 0.255 1.020 1.020 Pressure media Non-corrosive gas Excitation voltage 5 0.25 Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation voltage 8 Operating temperature 10 80 Storage temperature 20 100 Operating humidity 30 80 (No dew condensation) Electric performances/characteristics (Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25 ) Current consumption less than 10 Output impedance less than 10 Source current less than 0.2 Sink current less than 2 Mechanical response time 2 (For the reference) Full scale span voltage 4.0 Offset voltage 0.5 0.1 Full scale span voltage 4.5 0.1 Accuracy 5.0 Note ; Excluding input voltage error. 1 200KPG Unit 200 2.040 kPa kg/cm2 VDC VDC RH mA mA mA msec V V V FS/0 50 XFPN,XFGN-6 Data sheet Pre-amplified/5V Excitation/Gauge Outline dimensions Unit : mm XFPN 4 5 4.5 5 6 3 2 1 3 C0.5 3 2 4 0.6 Vent hole R1.5 15.24(600mil) 14 1 Pressure port 0.8 max 15 2.2 0.5 6 8 5 0.2 4 12 Terminal leads Labelled faceplate 6.8 2.8 Recommended footprint for PCB 6- 0.9(Diameter of through holes) 2.54 2.54 2.54 2.54 1.2 0.5 60 6- 1.8(Diameter of lands) 15.2 (Unit : mm) Unit : mm XFPN-R 4 0.2 8 0.8 Pressure port 2.2 0.5 3 14 R1.5 4 5 6 3 2 4.5 1 15.24(600mil) 5 max 15 6 4 5 12 C0.5 1 2 0.6 Vent hole 3 Terminal leads Recommended footprint for PCB 2.54 2.54 6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands) 2.54 2.54 60 1.2 0.5 Labelled faceplate 2.8 6.8 15.2 2 (Unit : mm) XFPN,XFGN-6 Data sheet Pre-amplified/5V Excitation/Gauge Outline dimensions Unit : mm XFPN-6 2.54 2.54 0.8 Pressure port 2 6 5 3 7 1 4 7 Vent hole 3 0.5 Projections 6 5 4 Recommended footprint for PCB 2-R0.5 1 Projections 2- 1(Holes for projections) 1.4 1.7 1 2 3 Land-pads Labelled faceplate 6.2 10.3 2.54 2.54 0.8 MA 0.25 X. 15 3.5 9.5 6 Index 6.2 9.4 (Unit : mm) Connection diagram XFPN, XFGN-6 Vcc(DC5V) Vcc Vout Vout GND C2 Remarks : C1 GND 1) C1 : Connect 680pF capacitor within 2cm distance from leads. 2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads. 3) 4 and 5 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or each other. Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 3 E-mail : [email protected]