X3GM-3,X3GM-6 Data sheet Pre-amplified/3V Excitation/Gauge Features . . . . . Applications . Industrial instrumentation . Pressure switch, Pneumatic device . Medical device 3V excitation, Battery operation available Volt level output On-chip amplification and temperature compensations Pre-calibration of offset voltage and span Non-corrosive liquid measurable (X3GMC only) Part number for ordering X3GM C - 3 025KP G S R Terminal leads direction (See Outline Diagram) R: Rated Pressure (Pa) Model X3GM Length of the pressure port Terminal leads configuration 3 : 3mm S : Surface mount package Pressure type 6 : 6mm Available pressure media G : Gauge (Positive pressure) No mark : Non-corrosive gas only GV : Gauge (Negative pressure) C : Non-corrosive gas and liquid GW : Gauge (Bipolar pressure) Pressure type Gauge pressure X3GM-3 X3GM-6 Surface mount package, 3mm pressure port Surface mount package, 6mm pressure port Model Package configuration Measurable pressure range (kPa) 100 100 0 100 0 25 0 50 0 100 0 200 0 1000 X3GM-3100KPGWSR X3GM-3100KPGVSR X3GM-3025KPGSR X3GM-3050KPGSR X3GM-3100KPGSR X3GM-3200KPGSR X3GM-3001MPGSR X3GM-3100KPGWSRH X3GM-3100KPGVSRH X3GM-3025KPGSRH X3GM-3050KPGSRH X3GM-3100KPGSRH X3GM-3200KPGSRH X3GM-3001MPGSRH X3GMC-3100KPGWSR X3GMC-3100KPGVSR X3GMC-3025KPGSR X3GMC-3050KPGSR X3GMC-3100KPGSR X3GMC-3200KPGSR X3GMC-3001MPGSR Part number for ordering X3GMC-3100KPGWSRH X3GM-6100KPGWSR X3GMC-3100KPGVSRH X3GM-6100KPGVSR X3GMC-3025KPGSRH X3GM-6025KPGSR X3GMC-3050KPGSRH X3GM-6050KPGSR X3GMC-3100KPGSRH X3GM-6100KPGSR X3GMC-3200KPGSRH X3GM-6200KPGSR X3GMC-3001MPGSRH X3GM-6001MPGSR X3GM-6100KPGWSRH X3GM-6100KPGVSRH X3GM-6025KPGSRH X3GM-6050KPGSRH X3GM-6100KPGSRH X3GM-6200KPGSRH X3GM-6001MPGSRH X3GMC-6100KPGWSR X3GMC-6100KPGVSR X3GMC-6025KPGSR X3GMC-6050KPGSR X3GMC-6100KPGSR X3GMC-6200KPGSR X3GMC-6001MPGSR X3GMC-6100KPGWSRH X3GMC-6100KPGVSRH X3GMC-6025KPGSRH X3GMC-6050KPGSRH X3GMC-6100KPGSRH X3GMC-6200KPGSRH X3GMC-6001MPGSRH Specifications Model/Rated pressure 100KPGW 100KPGV 025KPG 050KPG 100KPG 200KPG Recommended operating conditions Pressure type Gauge pressure 100 100 25 50 100 200 Rated pressure 1.020 1.020 0.255 0.510 1.020 2.040 Measurable pressure range 100 100 0 100 0 25 0 50 0 100 0 200 Pressure media 1 XFGM : Non-corrosive gas only, XFGMC : Non-corrosive gas and liquid Excitation voltage 3.0 0.3 Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation voltage 6 Operating temperature 10 80 Storage temperature 20 100 Operating humidity 30 80 (No dew condensation) Electric performances/characteristics (Excitation voltage Vcc=3.0V constant, Ambient temperature Ta=25 ) Current consumption less than 6 Output impedance less than 10 Source current less than 0.2 Sink current less than 2 Mechanical response time 2 (For the reference) Full scale span voltage 1.5 Offset voltage 2 0.5 0.0375 Full scale span voltage 2 2.0 0.0375 Accuracy 2 2.5 Note ; 1) Please consult us available liquid pressure media when you choose the C models. 2) Excluding input voltage error. 1 001MPG Unit 1000 10.20 0 1000 kPa kg/cm2 kPa VDC 1.5times of rated pressure VDC RH mA mA mA msec V V V FS/0 50 X3GM-3,X3GM-6 Data sheet Pre-amplified/3V Excitation/Gauge Outline dimensions Unit : mm X3GM-3 2.54 2.54 0.8 Pressure port 2 6 5 3 7 1 4 7 3 Vent hole 0.25 X. 6.5 MA 15 0.8 3.5 0.15 3 Index Recommended footprint for PCB 10.3 5 4 Labelled faceplate 1.7 1 2.54 2.54 1.4 6 1 2 9.4 Land-pads 3 (Unit : mm) Unit : mm X3GM-6 2.54 2.54 0.8 Pressure port 2 6 5 3 7 1 4 7 Vent hole 3 10.3 6 5 4 2-R0.5 3.5 Recommended footprint for PCB 2- 1(Holes for projections) 1.4 1.7 1 Projections 1 2 3 Labelled faceplate Land-pads 6.2 Projections 2.54 2.54 0.8 MA 0.5 X. 15 0.25 9.5 6 Index 6.2 9.4 (Unit : mm) 2 Pre-amplified/3V Excitation/Gauge X3GM-3,X3GM-6 Data sheet Connection diagram X3GM-3, X3GM-6 Vcc(DC3V) Vcc Vout Vout GND C2 C1 Remarks : 1)C1 : Connect 680pF capacitor within 2cm distance from leads. 2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads. GND 3)4 and 5 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or each other. Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 3 E-mail : [email protected]