JMK ZC-1072-10

ZC-1072-10
Operating voltage = 125 v~
Operating current (max) = 10 amperes
Frequency = dc - 400 Hz
Temperature range (storage) = -40 to 85 c
Temperature range (operating) = -20 to 60 c
Diel. withstanding voltage (ph - case) = 1000 v~
Diel. withstanding voltage (ph - ph) = 1000 vdc
Leakage current @ 125 v~, 60 hz = 0.6 ma max
Discharge voltage after 60 sec = 34 V max
Order p/n: ZC-1072-10
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
EUR
JMK Inc Glasgow G13 1DN Scotland UK
This filter provides very good common mode
and differential mode insertion loss for 10
amp single phase systems. This filter was
designed for military systems with requirements to meet the MIL-STD-461 emissions
specification. If a higher operating temperature is required contact the factory.
We can probably adjust the filter to meet your
requirements.
The standard construction is more than
adequate for most installation environments.
Should your application require operation in a
more severe environment JMK's engineering
staff can modify the mechanical construction
to meet the most severe design criteria.
Higher current models are also available
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]