(1/2) 001-01 / 20030823 / e9146_zgb_01u.fm ZGB-01U Series EMC Components EMC Filters for AC Power Supply Cased (Compact Size) FEATURES • These small and lightweight metal-cased EMC filters provide excellent EMC attenuation characteristics for differential mode noise components in the MF band. • Leakage current is maintained at less than 1mA. • Designed to ensure superior safety and reliability, easy implementation and maintenance. SAFETY STANDARDS Part No. ZGB22R5-01U ZGB2201-01U ZGB2202-01U ZGB2203-01U UL E62388 E62388 E62388 E62388 APPLICATIONS Digital applied devices (ECR, calculators, electronic scales, etc.), control devices, measurement devices, and other electronic equipment. 3 I 2 A 4 E 1 D SHAPES AND DIMENSIONS J Screw hole H F B G F C G Dimensions in mm Part No. A ZGB22R5-01U, 2201-01U, 2202-01U, 2203-01U 30 • Case: metal, terminal: lead wire (UL1015AWG#22) B 45 C 20 D 50 E 40 F 300 G 20 H M3 I 15 J 7.5 ELECTRICAL CHARACTERISTICS Part No. Rated voltage Eac(V) Rated current(A) Test voltage Eac(V)[Between terminal and case] Insulation resistance(MΩ) [DC. 500V, 1min/between terminal and case] Leakage current(mA)[250V • 60Hz] DC resistance(mΩ) Operating temperature range(°C)[Including self-temperature rise] With derating over(°C) Temperature rise(°C) Attenuation frequency range Differential mode at 40dB (MHz)[+5 to +35°C] Weight(g) • All specifications are subject to change without notice. ZGB22R5-01U 250 0.5 1500 ZGB2201-01U 250 1 1500 ZGB2202-01U 250 2 1500 ZGB2203-01U 250 3 1500 100min. 100min. 100min. 100min. 1max. 3000max. –10 to +85 55 30max. 1max. 1200max. –10 to +85 55 30max. 1max. 540max. –10 to +85 55 30max. 1max. 300max. –10 to +85 55 30max. 0.4 to 30 0.4 to 10 0.6 to 10 2 to 20 75 75 75 75 (2/2) 001-01 / 20030823 / e9146_zgb_01u.fm ZGB-01U Series EMC Components EMC Filters for AC Power Supply Cased (Compact Size) TYPICAL ELECTRICAL CHARACTERISTICS ATTENUATION vs. FREQUENCY CHARACTERISTICS ZGB22R5-01U ZGB2201-01U 80 80 60 40 Differential mode Attenuation(dB) 100 Attenuation(dB) 100 20 0 60 40 Differential mode 20 0.1 0.3 1 3 10 Frequency (MHz) 30 0 100 ZGB2202-01U 80 80 60 40 Differential mode Attenuation(dB) 100 Attenuation(dB) 0.3 1 3 10 Frequency (MHz) 30 100 ZGB2203-01U 100 60 40 Differential mode 20 0.1 0.3 1 3 10 Frequency (MHz) 30 100 4 Protective load 20 0 0.1 0 0.1 0.3 1 3 10 Frequency (MHz) 30 100 CIRCUIT DIAGRAM 1 2 3 Case GND INFORMATION Please note that products and some specifications have changed as indicated below. (1) Product Name Changes • Old series name ZGB12XX-11 • Old series name New series name [ZGB22XX-01U] ZGB22XX-01 New series products are all standardized to have the same size and dimensions. (2) Specification Improvement • Old series specifications ZGB12XX-11 Rated voltage: AC.125V Test voltage (between terminal and ground): AC.1000V Leakage current (125V, 60Hz): 0.4mA max. Regulatory approval: UL Display method: Label • Old series specifications ZGB22XX-01 Rated voltage: AC.250V Test voltage (between terminal and ground): AC.1500V Leakage current (250V, 60Hz): 1mA max. Regulatory approval: None Display method: Label • All specifications are subject to change without notice. • New series specifications [ZGB22XX-01U] Rated voltage: AC.250V Test voltage (between terminal and ground): AC.1500V Leakage current (125V, 60Hz): 0.4mA max. Leakage current (250V, 60Hz): 1mA max. Regulatory approval: UL Display method: Seal