JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50PA-420 LC HANDOVER TEST SYSTEM Frequency Range 800-2200 MHz Configuration 8 x 2 LC Handover Test System (See block diagram 092-5588) Impedance 50 Ohms nominal VSWR 1.5:1 maximum Attenuation Range 0-127 dB in 1 dB steps Attenuation Accuracy ± 0.4 dB or 2% of programmed (whichever is greater) Insertion Loss (ANT1-ANT8 to J1 or J2) 15.5 dB nominal at 800 MHz 18.5 dB nominal at 2200 MHz Power Divider Isolation 25 dB minimum RF Input Power +20 dBm average +30 dBm (no damage) Switching Speed 5 microseconds typical (after command is received and processed) (3 milliseconds typical processing time) AC Supply 100-240 VAC @ 47-63 Hz Manual Control Keypad and LCD display Remote Control Ethernet (10/100) and RS-232 Remote Commands Variable Handover Feedback Handover Fade Attenuator Feedback Fade Pause Set Attenuator Read Attenuator Change Baud Rate Identification RF Connector SMA or N female Operating Temperature Range 0ºC to +50ºC --CONTINUED-Page 1 of 2 JFW FORM E-7-F REV F (VHND Av Aw Vx Vy Tz) (FHND Av Aw Vx Vy Tz) (FAx y z t) (FFAx y z t) (PAUSEx) (SAx y) (RAx) (CBx) (IDN) JFW Industries, Inc. Phone: 317-887-1340 [email protected] www.jfwindustries.com SPECIFICATION SHEET JFW MODEL 50PA-420 LC HANDOVER TEST SYSTEM Physical Size ECR/ECN # Page 2 of 2 DATE See outline drawing 092-5589 REV APPR / DATE 15916 04/30/2008 05/28/2008 A TRS 04/30/2008 TRS 05/28/2008 15969 06/04/2008 B TRS 06/04/2008 ECR/ECN # 16179 JFW FORM E-7-F REV F DATE 08/07/2008 REV C APPR / DATE TRS 08/07/2008