Bulletin 700-SA Solid-State Relays Overview/Product Selection Bulletin 700-SA Table Of Contents • • • • • Product Selection . . . . . . . Accessories . . . . . . . . . . . . Specifications . . . . . . . . . . Approximate Dimensions . . . . . . . . . . . . 5 A (Resistive) Max. Continuous Load Current 264V AC or 125V DC Max. Load Voltage Range Photocoupler Isolation Between Control and Load Voltage LED Indicator for Input/Logic ON/OFF Status Monitoring 700-HN100, -HN125, -HN 202, or -HN108 Socket Compatible 31 32 34 36 Product Selection Input-to-Output Isolation Method Zero Cross Function LED Indicator Yes Photocoupler Rated Output (Load) Max. Current and Voltage Range 5 A @100…240V AC Yes — Rated Input Control Voltage Cat. No. Factory-stocked Item (Single Pack) 700-SAZY5Z25 ✔ 700-SANY3Z25 ✔ 5…24V DC 3 A @ 5…110V DC 31 Bulletin 700-SA Solid-State Relays Accessories Description Pkg. Quantity Cat. No. Factory-stocked Item Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction Order ten or multiples of ten 10 700-HN100 ✔ Specialty Socket 8-pin backwired socket with solder terminals Order ten or multiples of ten 10 700-HN108 ✔ Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style Construction Order must be for 10 sockets or multiples of 10. No retainer clip required. 10 700-HN125 ✔ DIN Rail Mounting Pack Standard 35 x 7.5 mm DIN Rail, 1 meter long, 10 rails per package. Order must be for 10 rails or multiples of 10. 10 199-DR1 ✔ Pre-printed identification tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 700-N40 Blank identification tags — contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 700-N41 Retainer Clip for Cat. No. 700-HN153 Sockets with 700-SA Relays Secures relay in socket. Order must be for 10 clips or multiples of 10. 10 700-HN158 ✔ 8-Pin Socket — can be used with or without timing attachment Order ten or multiples of ten 10 700-HN202 ✔ Cat. No. 700-HN100 Cat. No. 700-HN108 Cat. No. 700-HN125 Cat No. 199-DR1 Sample Retainer Clips 32 Bulletin 700-SA Solid-State Relays Accessories, Continued Description Multi-Function Multi-Range Time Module Pkg. Quantity Cat. No. 1 700-HT2 Factory-stocked Item Cat. No. 700-HT2 33 Bulletin 700-SA Solid-State Relays Specifications Control/Input Ratings Cat. No. Control Voltage Levels Rated Control Voltage Operating Control Voltage Range Impedance 5…24V DC 4…30V DC 1.5 K Ω (+20% -10%) 700-SAZY5Z25 700-SANY3Z25 Pick-up Voltage Drop-out Voltage 4V DC max. 1V DC min. Load/Output Ratings Applicable Load Cat. No. Rated Load Voltage Continuous Load Current (Resistive) Load Voltage Range Max. Inrush Current ➊ Max. ➋ — — — Min. 700-SAZY5Z25 100…240V AC 75…264V AC 0.1 A 5.0 A 80 A, @50/60 Hz for 1 cycle 700-SANY3Z25 5…110V DC 3…125V DC 0.1 A 3.0 A 12 A (10 ms) Characteristics Item 700-SAZY5Z25 Load Switching Method/Device 700-SANY3Z25 Triac Transistor Pick-up time 1/2 cycle of load power source + 1 ms max. 0.5 ms max. Drop-out time 1/2 cycle of load power source + 1 ms max. 2.5 ms max. Output ON voltage drop 1.6 V (RMS) max. 1.5 V max. Output Leakage current 5 mA max. (at 100V AC); 10 mA max. (at 200V AC) 5 mA max. (at 125V DC) Output VDRM VCEO (V) 600 150 Output di/dt (A/uS) 50 — Output dv/dt (V/uS) 500 — Output I2t (A2S) 41.6 — Output Tj (°C) Max. 125 150 Insulation resistance 100 MΩ min. (at 500V DC) Dielectric strength 1,500V AC, 50/60 Hz for 1 min. Vibration resistance (max.) 10…55 Hz, 1.5 mm double amplitude (10 G) 1,000 m/s2 (100 G) Shock resistance (max.) Ambient temperature Operating Storage –30…80°C (–22…176°F) with no icing or condensation –30…100°C (–22…212°F) with no icing or condensation Ambient humidity 45…85% (no condensation) Standards UL508, CSA C22.2 , VDE, CE Weight Approx. 70 g ➊ If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to “Inrush Current Resistivity” graphs below. ➋ Refer to the following graph "Load Current Vs. Ambient Temperature Characteristics" for additional load current details. Load Current vs. Ambient Temperature Characteristics 700-SA Load current (A) 700-SAZY5Z25 700-SANY3Z25 Inrush current (A. Peak) 700-SA Inrush Current Resistivity ➌ 700-SAZY5Z25 700-SANY3Z25 Ambient temperature (°C) Energizing time (ms) ➌ Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR. 34 Bulletin 700-SA Solid-State Relays Specifications, Continued Terminal Arrangement (Bottom View) (–) Load Load Load power supply ( Input ) (+) Input voltage – Note: + The plus and minus symbols shown in parentheses are for DC loads. Basic Application Considerations High Density Mounting of Multiple SSRs If multiple SSRs are installed side by side be aware that the outer case wall of the SSR serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current to half. Protective Component When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built-in surge suppression (Bulletins 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device . Select a varistor that meets the conditions of the load voltage outlined in the table below. Load Voltage Varistor Voltage 100…120V AC 240…270 V 200…240V AC 440…470 V 380…480V AC 820…1000 V Varistor Surge Resistance 1000 A min. For additional details applying solid-state relays, refer to pub. 700-AT001A-EN-E, "Solid-State Relay Application Guide" available at www.theautomationbookstore.com. 35 Bulletin 700-SA Solid-State Relays Approximate Dimensions Note: All units in millimeters unless otherwise indicated. Dimensions are not intended to be used for manufacturing purposes. 700-SA ➊ 35 max. 35 max. ➊ Bulletin 700-SA is compatible with cat. nos. 700-HN100, -108, -125, and -202 (sockets). 36 52.5 max.