Bulletin 700-SC Solid-State Relays Overview/Product Selection Bulletin 700-SC Table Of Contents • • • • • • Product Selection . . . . . . . Accessories . . . . . . . . . . . . Specifications . . . . . . . . . . Approximate Dimensions . . . . . . . . . . . . 3 A (resistive) Max. Continuous Load (Output) Current 264V AC, 48V DC or 125V DC Max. Load Voltage Range Options 5…24V DC or 110/220V AC Control (Input) Voltage Options LED Indicator (Optional) For Input/Logic ON/OFF Status Monitoring 700-HN103, 700-HN104, or 700-HN128 Socket Compatible Compatible with 700-AT1 or 700-AT2 Timer Module 37 38 39 41 Product Selection Input-to-Output Isolation Method Zero Cross Function Photocoupler Yes LED Indicator Rated Output (Load) Max. Current and Voltage Range 3 A @100…240V AC Photocoupler Phototriac 5…24V DC 700-SCZY3Z25 ✔ 100/110V AC 700-SCZY2A1 ✔ ✔ 200/220V AC 700-SCZY2A2 3 A @100…240V AC 24V DC 700-SCTY3Z24 ✔ No 3 A @ 4…48V DC 5…24V DC 700-SCNY3Z25 ✔ 4…24V DC 700-SCZN3Z26 ✔ 24V DC 700-SCTN3Z24 ✔ 3 A @ 4…48V DC 4…24V DC 700-SCNN3Z26 ✔ 2 A @ 5…110V DC 5…24V DC 700-SCNN2Z25 ✔ Yes 3 A @ 100…240V AC No No Photocoupler Cat. No. No Yes Phototriac 2 A @ 100…240V AC Factorystocked Item (Single Pack) Rated Input Control Voltage N/A 37 Bulletin 700-SC Solid-State Relays Accessories Description Pkg. Quantity Cat. No. Factory-stocked Item Screw Terminal Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction Order must be in ten or multiples of ten 1 700-HN103 ✔ Screw Terminal Socket – Panel or DIN Rail Mounting. Guarded Terminal Construction 14-blade miniature socket for use with Bulletin 700-SC relays. This socket has coil and contact separation as well as the ability to plug in optional plug in modules (700-A** accessories: LED, Surge Suppression, Timing Modules) 10 700-HN104 ✔ Screw Terminal Base Socket — Panel or DIN Rail Mounting; Open Style Construction Order must be in multiples of ten 10 700-HN128 ✔ DIN Rail Mounting Pack Standard 35 x 7.5 mm DIN Rail, 1 meter long, 10 rails per package. Order must be for 10 rails or multiples of 10. 10 199-DR1 ✔ Pre-printed identification tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 700-N40 Blank identification tags — contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 700-N41 Retainer Clip Secures relay in socket. Order must be for 10 clips or multiples of 10. 10 700-HN114(B)➊ ON-Delay Time Module Voltage Range: 12…24V AC/DC used with 700-HN153 socket 1 700-AT1 One Shot Timing Module Voltage Range: 12…24V AC/DC used with 700-HN153 socket 1 700-AT2 Cat. No. 700-HN103 Cat. No. 700-HN104 Cat. No. 700-HN128 Cat No. 199-DR1 Sample Retainer Clips ➊ Series B retainer clip must be used with Bulletin 700-SC 38 ✔ Bulletin 700-SC Solid-State Relays Specifications Control/Input Ratings Control Voltage Levels Cat. No. Rated Control Voltage Operating Control Voltage Range Impedance 700-SCZY3Z25 5…24V DC 4…28V DC 15 mA max. ➊ 4V DC max. 1V DC min. 700-SCZY2A1 100/110V AC 75…125V AC 41 KΩ± 20% 75V AC max. 20V AC min. 700-SCZY2A2 200/220V AC 150…250V AC 72 KΩ ± 20% 150V AC max. 40V AC min. 700-SCTY3Z24 24V DC 19.2…28.8V DC 2 KΩ ± 20% 19.2V DC max. 4V DC max. Pick-up Voltage 700-SCNY3Z25 5…24V DC 4…28V DC 1.5 KΩ + 20%/–10% ➋ 700-SCZN3Z26 4…24V DC 3…28V DC 15 mA max. ➊ 3V DC max. 700-SCTN3Z24 24V DC 19.2…28.8V DC 2 kΩ ± 20% 19.2V DC max. 700-SCNN3Z26 4…24V DC 700-SCNN2Z25 5…24V DC 3…28V DC 1.5 KΩ + 20%/–10% ➋ 3V DC max. Drop-out Voltage 1V DC min. Load/Output Ratings Applicable Load Cat. No. Rated Load Voltage Load Voltage Range — — — Continuous Load Current (Resistive) Min. Max. ➍ 0.1 A 3A Max. Inrush Current ➌ — 700-SCZY3Z25 700-SCTY3Z24 700-SCZN3Z26 100…240V AC 75…264V AC 700-SCTN3Z24 700-SCZY2A1 700-SCZY2A2 100…240V AC 700-SCNN3Z25 700-SCNN2Z25 0.1 A 2A 4…48V DC 3…52.8V DC 0.1 A 3A 18 A (10 ms) 5…110V DC 3…125V DC 0.1 A 2A 10 A (10 ms) 700-SCNY3Z26 ➊ ➋ ➌ ➍ 45 A (@50/60 Hz, 1 cycle) With constant current input circuit system. SSR impedance varies with a change in input voltage. Input impedance attains its maximum at the operating voltage. If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to “Inrush Current Resistivity” graphs on page 40 for details. Refer to the following "Load Current Versus Ambient Temperature Characteristics" graphs on page 40 for additional load current details. Characteristics Cat. No. 700-SCZ…. 700-SCT 700-SCNN3… Triac Load Switching Method/Device 700-SCNN2… Transistor 1/2 of load power source + 1 ms max. (DC input) 1 ms max 0.5 ms max 0.5 ms max 1/2 of load power source + 1 ms max 2 ms max 2.5 ms max 1.6 V (RMS) max 1.6V (RMS) 1.5 V max. 1.5V max. Output Leakage Current 5 mA max (@ 100 V AC) 10 mA max (@ 200 V AC) 2.5 mA max (@ 100 V AC) 5 mA max (at 200 V AC) 5 mA max (@ 50 V DC) 0.1 mA max (@ 100 V DC) Output VDRM, VCEO (V) 600 600 80 80 Output di/dt (A/uS) 50 50 — — Output dv/dt (V/uS) 250 250 — — Output I2t (A2S) 18 18 — — Output Tj °C Max. 125 125 150 150 Pick-up Time 3/2 of load power source + 1 ms max. (AC input) 1/2 of load power source + 1 ms max. (DC input) Drop-out Time 3/2 of load power source + 1 ms max. (AC input) Output ON Voltage Drop Insulation Resistance 100 MΩ min (@ 500V DC) Dielectric Strength 1,500 V AC, 50/60 Hz for 1 minute Vibration Resistance (max.) 10…55 Hz, 1.5 mm double amplitude (10 G) Shock Resistance (max.) 1,000 m/s2 (100 G) Ambient Temperature Operating: -30°C…80°C (-22...176°F) with no icing or condensation Storage: -30°C…100°C (-22...212°F) with no icing or condensation 39 Bulletin 700-SC Solid-State Relays Specifications, Continued Characteristics Standards UL508, CSA C 22.2, CE, VDE Ambient Humidity Operating: 45%…85% (no condensation) Weight Approx. 50 g Load Current Versus Ambient Temperature Characteristics 700-SC_ _2... Load current (A) Load current (A) 700-SC_ _3... Ambient temperature (°C) Ambient temperature (°C) Inrush Current Resistivity➊ Inrush current (A. Peak) 700-SCNY3 700-SCNN2... Inrush current (A. Peak) 700-SCNN3... 700-SCT... Inrush current (A. Peak) 700-SCZ.... 10 Energizing time (ms) Energizing time (ms) 20 Energizing time (ms) ➊ Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR. 40 Bulletin 700-SC Solid-State Relays Approximate Dimensions Note: Bulletin 700-SC is compatible with the 700-HN103, 700-HN104, and 700-HN128 sockets. All units in millimeters unless otherwise indicated. Dimensions are not intended for manufacturing purposes. Terminal Arrangement/ Internal Connections (Bottom View) 28 max. 1 4 5 8(+) 9 Load Load (+) 12(–) (–) 21.5 max. 13 36.5 max. Input 14 – 42.5 max. – Cat, No 700-SC… ➊ Note: Load power supply + Input voltage + The plus and minus symbols shown in parentheses are for DC loads. ➊ Bulletin 700-SC is compatible with cat. nos. 700-HN103, -HN104, and -HN128 socket. Basic Application Considerations For Bulletin 700-SC Connection For DC Load Switching, Bulletin 700-SC will operate properly if the load is connected to either the positive or negative SSR load terminal. High-density Mounting of Multiple SSRs If multiple relays are mounted side by side, be aware that the outer wall of each SSR works as a radiator. The SSR casing serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half. Protective Component When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built-in surge suppression (Bulletins 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device . Select a varistor that meets the conditions of the load voltage outlined in the table below. Note: For additional details applying solid-state relays, refer to pub. number 700-AT001A-EN-E, "Solid-State Relay Application Guide." Document available at www.theautomationbookstore.com. Load Voltage Varistor Voltage 100…120V AC 240…270 V 200…240V AC 440…470 V 380…480V AC 820…1000 V Varistor Surge Resistance 1000 A min. 41