ETC 8534-0024

85 Series
Miniature Plug-in Timers 5 - 10 A
• Six time scales, from 0.1s to 10h
• Each timer has 2 functions
• Supply voltage: 12, 24, 48, 110/125 V AC/DC (non polarized);
230/240 V AC
• Functions and time scales set by DIP switches situati sulla parte superiore del relè
• LED indication
• 2 CO (DPDT), 3 CO (3PDT) 10 A 250 V AC1 or 4 CO (4PDT) 5 A 252 V AC1
contacts available
• Sockets and accessories: see 94 series
• Conforms to EN 61812-1 standard
• Approvals (according to type): CSA, cULus
INDUSTRIAL
APPLIANCES
INDUSTRIAL
AUTOMATION
11
85 Series
Miniature Plug-in Timers 5 - 10 A
85.54
85.32
®
®
C
C
US
MINIATURE PLUG-IN TIMERS 5 - 10 A
TYPE 85.32 2 CO (DPDT) 10 A
TYPE 85.33 3 CO (3PDT) 10 A
TYPE 85.34 4 CO (4PDT) 5 A
- Functions available, see page 13:
ON delay (AI)
ON pulse (DI)
- 2.0 x 0.5 mm terminals
- LED indication: red = relay ON
green = power ON
- Mounting: see 94 series sockets
- Ordering information: see page 15
US
MINIATURE PLUG-IN TIMERS 5 - 10 A
TYPE 85.52 2 CO (DPDT) 10 A
TYPE 85.53 3 CO (3PDT) 10 A
TYPE 85.54 4 CO (4PDT) 5 A
- Functions available, see page 13:
symmetrical recycler: pulse start (SW)
symmetrical recycler: pause start (SP)
- 2.0 x 0.5 mm terminals
- LED indication: red = relay ON
green = power ON
- Mounting: see 94 series sockets
- Ordering information: see page 15
27.7
1.9
14.5
59.1
20.6
3.6
20.6
3.7
13.2
3.7
1
5 4
8
12
9
13
1
6.6
4 2
14
85.32 / 85.52
5
8
7
U
12
3.7
13
3.7
3
3.7
6
9
14
U
85.33 / 85.53
1
5 2
4.4
6
10
9
3.7
11
13
4.1
7 4
3
8
12
14
U
85.34 / 85.54
6.1
7.2
58
20.6
6.3
6.7
85 Series
Miniature Plug-in Timers 5 - 10 A
EMC SPECIFICATIONS
TYPE OF TEST
REFERENCE STANDARD
ELECTROSTATIC DISCHARGE - contact discharge
EN 61000-4-2
n.a.
- air discharge
8 kV
RADIO-FREQUENCY ELECTROMAGNETIC FIELD (80 ÷ 1000 MHz)
ENV 50140 (IEC 1000-4-3)
15 V/m
EN 61000-4-4
4 kV
EN 61000-4-5
4 kV
ENV 50141 (IEC 1000-4-6)
10 V
EN 61000-4-8
30 A/m
EN 55022
class B
FAST TRANSIENTS (burst) (5-50 ns, 5 kHz) on Supply terminals
SURGES (1.2/50 µs) on Supply terminals
- common mode
- differential mode
2 kV
RADIO-FREQUENCY COMMON MODE (0.15 ÷ 80 MHz)
on Supply terminals
POWER-FREQUENCY (50 Hz)
RADIATED AND CONDUCTED EMISSION
DESCRIPTION OF THE FUNCTIONS
The (C) indicated in the diagrams refers to the position of the NO contacts.
When the red LED (C) is illuminated the NO contact are closed.
U = SUPPLY VOLTAGE
Types
85.32
85.33
85.34
C = RELAY CONTACT (NO)
U
C
1234
t<T
T
(DI) ON pulse.
Apply power to timer.
Contact transfers immediately.
After preset time has elapsed, contact returns to original position.
U
12 3 4
Types
85.52
85.53
85.54
C
t<T
T
U
C
12 3 4
T
T
T
T
t<T
U
C
12 3 4
T
T
T
T
(AI) ON delay.
Apply power to timer.
Contact transfers after preset time has elapsed.
Reset occurs when power is removed.
T
t<T
(SW) Symmetrical recycler: pulse start.
Apply power to timer.
First transfer of contact occurs as soon as power is applied.
The timer now cycles between ON and OFF as long as
power is applied. The ratio is 1:1 (time off = time on).
(SP) Symmetrical recycler: pause start.
Apply power to timer.
First transfer of contact occurs after preset time has elapsed.
The timer now cycles between OFF and ON as long as power
(time off = time on).
TIME SCALES
(0.1...1) s
(1...10) s
(10...60) s
(1...10) min
(10...60) min
(1...10) h
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
13
85 Series
Miniature Plug-in Timers 5 - 10 A
TECHNICAL DATA
SUPPLY VOLTAGE (UN)
12, 24, 48, 110/125 V AC/DC (non polarized)
230/240 V AC
OPERATING RANGE
AC (50/60 Hz)/DC: (0.85...1.1)UN
POWER CONSUMPTION
AC: ≤ 2 VA
DIELECTRIC STRENGTH
2 (DPDT) - 3 CO (3PDT)
4 CO (4PDT)
between coil and contacts:
2,000 V
2,000 V
between open contacts:
1,000 V
1,000 V
between adjacent contacts:
2,000 V
1,550 V
1,500 V
1,500 V
DC: ≤ 2 W
between frame and live parts:
MECHANICAL LIFE
10 · 106 cycles
PROTECTION CATEGORY
IP 40
DELAY SETTING
0.1 s...10h (see time scales)
REPEATABILITY
± 2%
SETTING ACCURACY - FULL RANGE
± 5%
RECOVERY TIME
≤ 20 ms
AMBIENT TEMPERATURE
(–20...+60)°C
POWER LOST IN THE ENVIRONMENT
85.x2.8.230
85.x3.8.230
85.x4.8.230
- without load:
0.6 W
0.6 W
0.6 W
- at full load:
3.7 W
4.7 W
3.3 W
WORKING CONDITIONS: in conformity with EC Directive on EMC (89/336), the timer has a high level of immunity, both from radiated and
conducted disturbances (according to EN 61812-1). However, the timer (and its supply and control wiring) must be installed as far as possible from
disturbance sources (such as transformers contactors, circuit-breakers and their power cables).
CONTACT SPECIFICATIONS
RATED CURRENT
MAXIMUM PEAK CURRENT
3 CO (3PDT)
4 CO (4PDT)
10 A
10 A
5A
20 A
20 A
10 A
RATED VOLTAGE
250 V AC
250 V AC
250 V AC
MAXIMUM SWITCHING VOLTAGE
400 V AC
400 V AC
400 V AC
NOMINAL RATE IN AC1
2,500 VA
2,500 VA
1,250 VA
500 VA
500 VA
250 VA
see diagram H 85
see diagram H 85
see diagram H 85
NOMINAL RATE IN AC15 (230 V)
BREAKING CAPACITY IN DC1
SINGLE PHASE MOTOR RATING (230 V AC)
ELECTRICAL LIFE IN AC1
CONTACT RESISTANCE: initial
CONTACT MATERIAL
14
2 CO (DPDT)
0.37 kW/0.6 HP
0.37 kW/0.6 HP
0.125 kW/0.2 HP
see diagram F 85/2
see diagram F 85/2
see F 85/1
≤ 50 mΩ
≤ 50 mΩ
≤ 50 mΩ
AgNi
AgNi
AgNi
85 Series
Miniature Plug-in Timers 5 - 10 A
F 85/1
F 85/2
7
10
CYCLES
CYCLES
107
106
105
6
10
5
0
0.5
1.5
1.0
10
2
0
1
LOAD (kVA)
2
3
4
LOAD (kVA)
DC contact life vs AC1 load. 4 CO types (5 A)
Contact life vs AC1 load. 2 - 3 CO types (10 A)
H 85
MAX SWITCHING CURRENT (A)
20
10
A
B
C
D
6
1
4
2
1
0.6
0.4
0.2
0.1
20
60
100
140
180
220
VOLTAGE DC (V)
Breaking capacity for DC1 load.
1 = 4 CO type
A = load applied to 1 contact
B = load applied to 2 contacts in series
C = load applied to 3 contacts in series
D = load applied to 4 contacts in series
ORDERING INFORMATION
Example: 85 series timer, 4 CO (4PDT), 24 V AC/DC supply voltage with AI - DI functions.
8 5
3
Series
Type
3 = Functions: AI - DI
5 = Functions: SW - SP
4
No. of poles
2 = 2 CO (DPDT) - 10A
3 = 3 CO (3PDT) - 10A
4 = 4 CO (4PDT) - 5A
0
0 2 4
Coil version
0 = AC (50/60 Hz)/DC
8 = AC (50/60 Hz)
for 230 V only
0
0
0
0
Coil voltage
012 = 12 V AC/DC
024 = 24 V AC/DC
048 = 48 V AC/DC
110 = 110/125 V AC/DC
230 = 230/240 V AC
15
94 Series - Sockets and Accessories
for 85 Series Timers
A range of sockets and accessories for 85 series timers
Features include:
• PCB, screw terminal, panel or 35 mm rail (EN 50022) mount versions
• Flammability in conformity with UL 94
• Approvals (according to type): BBJ, CSA, DEMKO, CS - IMQ, SEV, cULus
16
94 Series - Sockets and Accessories
for 85 Series Timers
94.22
94.14
P.C.B. SOCKETS
TYPE 94.12 for types 85.32 - 85.52
TYPE 94.13 for types 85.33 - 85.53
TYPE 94.14 for types 85.34 - 85.54
PANEL MOUNT SOLDER SOCKETS (1 mm thick panel mount)
TYPE 94.22 for types 85.32 - 85.52
TYPE 94.23 for types 85.33 - 85.53
TYPE 94.24 for types 85.34 - 85.54
CHARACTERISTICS
- LOAD: 10 A 250 V
- ISOLATION RESISTANCE: ≥ 103 MΩ
- DIELECTRIC STRENGTH: ≥ 2 kV AC
- MATERIAL: self-extinguishing PPEm (V1)
- CONNECTIONS: Cu Sn 6 tin plated
CHARACTERISTICS
- LOAD: 10 A 250 V
- ISOLATION RESISTANCE: ≥ 103 MΩ
- DIELECTRIC STRENGTH: ≥ 2 kV AC
- MATERIAL: polycarbonate (PC)
- CONNECTIONS: Cu Sn 6 silver plated
=
6.6
=
=
=
=
29.5
5
11.5
25.5
29.5
29.5
29.5
25.5
7.5
=
94.22
5.3
4.1
1.5
29.5
1.5
7.5
6.3
21.5
94.23
94.24
14.5
=
5.3
4.1
6.5
1.5
29.5
6.3
6.5
5.3
4.1
4.4
=
=
6.3
6.5
13.2
13.5
94.14
21.5
25.8
94.13
21.5
11.5
1
94.12
=
5
29.5
21.5
29.5
21.5
29.5
21.5
7.5
=
=
21.5
21.5
21.5
94.12
94.13
94.14
21.8
17
94 Series - Sockets and Accessories
for 85 Series Timers
94.64
94.34
PANEL MOUNT SOLDER SOCKETS (M3 screw mount)
TYPE 94.32 for types 85.32 - 85.52
TYPE 94.33 for types 85.33 - 85.53
TYPE 94.34 for types 85.34 - 85.54
CLAMP TERMINALS SOCKETS
(panel or 35 mm rail - EN 50022- mount)
TYPE 94.62 for types 85.32 - 85.52
TYPE 94.64 for types 85.34 - 85.54
Accessories: TYPE 094.81 retaining clip
CHARACTERISTICS
- LOAD: 10 A 250 V
- ISOLATION RESISTANCE: ≥ 103 MΩ
- DIELECTRIC STRENGTH: ≥ 2 kV AC
- MATERIAL: self-extinguishing PPEm (V1)
- CONNECTIONS: Cu Sn 6 tin plated
26
22.5
3.1
=
3.1
94.34
=
94.33
20.5
66.5
40.5
66.5
94.32
33
26
22.5
=
16.5
13.5
=
21.5
40.5
21.5
40.5
21.5
CHARACTERISTICS
- LOAD: 10 A 250 V
- ISOLATION RESISTANCE: ≥ 103 MΩ
- DIELECTRIC STRENGTH: ≥ 2 kV AC
- MATERIAL: self-extinguishing PPEm (V1)
- CONNECTIONS: Cu Zn 33 nickel plated
- PROTECTION CATEGORY: IP 20
- Non removable pozidrive slotted terminal screws.
- Identification label.
7.5
3.2
=
34
26.5
=
17.5
44
8
14
5
NO
44
8
34
7
24
6
14
5
NO
42
4
12
1
NC
42
4
32
3
22
2
12
1
NC
A2
14
A1
13
COIL
A2
14
A1
13
COIL
41
12
11
9
COM
41
12
11
9
COM
7.5
22.5
94.62
18
31
11
21
10
94.64
94 Series - Sockets and Accessories
for 85 Series Timers
94.74
94.82
SCREW TERMINALS SOCKETS
(panel or 35 mm rail - EN 50022- mount)
TYPE 94.73 for types 85.32 - 85.52
TYPE 94.74 for types 85.34 - 85.54
Accessories: TYPE 094.81 retaining clip
SCREW TERMINALS SOCKETS
(panel or 35 mm rail - EN 50022- mount)
TYPE 94.82 for types 85.32 - 85.52
Accessories: TYPE 094.81 retaining clip
CHARACTERISTICS
- LOAD: 10 A 250 V
- ISOLATION RESISTANCE: ≥ 103 MΩ
- DIELECTRIC STRENGTH: ≥ 2 kV AC
- MATERIAL: self-extinguishing PPEm (V1)
- CONNECTIONS: Cu Zn 33 nickel plated
- PROTECTION CATEGORY: IP 20
- Non removable pozidrive slotted terminal screws.
- Identification label.
CHARACTERISTICS
- LOAD: 10 A 250 V
- ISOLATION RESISTANCE: ≥ 103 MΩ
- DIELECTRIC STRENGTH: ≥ 2 kV AC
- MATERIAL: self-extinguishing PPEm (V1)
- CONNECTIONS: Cu Zn 33 nickel plated
- PROTECTION CATEGORY: IP 20
- Non removable pozidrive slotted terminal screws.
- Identification label.
29.5
71.3
3
23
24
30
36.3
Ø 4.2
4.1
68
70.5
34.2
23
24
26
30
27
26
34
6
24
5
14
4
NO
44
8
34
7
24
6
14
5
32
3
22
2
12
1
NC
42
4
32
3
22
2
12
1
A2
31
9
21
8
94.73
A1
COIL
A2
14
11
7
COM
41
12
31
11
21
10
94.74
NO
42
4
12
1
NC
44
8
14
5
NO
41
12
11
9
COM
A2
14
A1
13
COIL
NC
A1
13
COIL
11
9
COM
19
94 Series - Sockets and Accessories
for 85 Series Timers
94.04
094.06
CLAMP TERMINALS SOCKETS
(panel or 35 mm rail - EN 50022- mount)
TYPE 94.02 for types 85.32 - 85.52
TYPE 94.04 for types 85.34 - 85.54
Accessories: TYPE 094.81 retaining clip
Accessories: TYPE 094.06 6-way jumper link
6-WAY JUMPER LINK
TYPE 094.06 for socket 94.02 and 94.04
CHARACTERISTICS
- LOAD: 10 A 250 V
CHARACTERISTICS
- LOAD: 10 A 250 V
- ISOLATION RESISTANCE: ≥ 103 MΩ
- DIELECTRIC STRENGTH: ≥ 2 kV AC
- MATERIAL: self-extinguishing PA 6 20% FV (V1)
- CONNECTIONS: Cu Zn 33 nickel plated
- PROTECTION CATEGORY: IP 20
- Non removable pozidrive slotted terminal screws.
- Identification label.
61
26
27
17.5
135
17.5
3.3
27
10.3
7
5.1
76
0.75
32
41
12
11
9
COM
41
12
31
11
21
10
11
9
COM
44
8
14
5
NO
44
8
34
7
24
6
14
5
NO
42
4
12
1
NC
42
4
32
3
22
2
12
1
NC
A2
14
A1
13
A2
14
A1
13
94.02
20
COIL
94.04
COIL
35.5
26.25
27
27
27
26.25