ETC 5512-9024

55 Series - Miniature General
Purpose relays 5 - 10 - 16 A
A range of miniature general purpose relays, with 1, 2, 3 or 4 CO contacts
Features include:
• P.C.B. version
• AC or DC coils
• B250 insulation group (in accordance with VDE 0110)
• Can be used with supply status indication, coil protection and timer modules
• Approvals (according to type): BBJ, BEAB, CSA, DEMKO, FIMKO, GOST, IMQ,
NEMKO, RINA, SEMKO, SEV, cUL, UTE, VDE
INDUSTRIAL
AUTOMATION
AUTOMATIC
GATES
TEXTILE
MACHINES
INDUSTRIAL
APPLIANCES
PLASTIC
MOULDING
MACHINES
ELECTRONIC
APPLIANCES
WHITE
GOODS
MEDICAL
EQUIPMENT
43
55 Series - Miniature General
Purpose relays 5 - 10 - 16 A
55.11
55.12
GOST
RINA
RINA
C
MINIATURE GENERAL PURPOSE RELAYS 1 CO (SPDT) 16 A
TYPE 55.11 P.C.B. mount
- Tin plated brass connections:
1.2 x 0.5 mm for P.C.B. versions
- Standard contact material: AgCdO (contact option not available)
- Options: see coding table page 49
- Ordering information: see page 49
C
MINIATURE GENERAL PURPOSE RELAYS 2 CO (DPDT) 10 A
TYPE 55.12 P.C.B. mount
- Tin plated brass connections:
1.2 x 0.5 mm for P.C.B. versions
- Standard contact material: AgNi
- Options: see coding table page 49
- Ordering information: see page 49
20.7
27.7
35
27.7
6.1
5
35
20.7
GOST
BEAB
1.9
BEAB
3.75
3.75 13.2
6.6
3.75 13.2
6.35 4.1 4.3
copper side view
6.6
20.6
13.2
3.7
3.7
13.2
3.7
1
8
9
12
14
1.5
5
13
44
4.1
4
6.3
6.7
27.5
27.5
1.5
1-4 5-8
1
6.35 4.1 4.3
copper side view
20.6
3.7
3.75
9 - 12
13
14
1
5
4
8
4.1
4
5
8
9
12
13
14
6.3
6.7
9
12
13
14
55 Series - Miniature General
Purpose relays 5 - 10 - 16 A
55.13
55.14
GOST
GOST
RINA
RINA
27.7
27.7
35.5
20.7
6.1
5
35
20.7
MINIATURE GENERAL PURPOSE RELAYS 4 CO (4PDT) 5 A
TYPE 55.14 P.C.B. mount
- Tin plated brass connections:
1.2 x 0.5 mm for P.C.B. versions
- Standard contact material: AgNi
- Options: see coding table page 49
- Ordering information: see page 49
1.9
MINIATURE GENERAL PURPOSE RELAYS 3 CO (3PDT) 10 A
TYPE 55.13 P.C.B. mount
- Tin plated brass connections:
1.2 x 0.5 mm for P.C.B. versions
- Standard contact material: AgNi
- Options see coding table page 49
- Ordering information: see page 49
3.75
6.6
3.75
6.6
6.35 4.1 4.3
3.75
copper side view
5 3
6
3.7
4.1
3
4
5
6
7
8
9
13
4 2
14
6.3
6.7
1.5
2
6.35 4.1 4.3
20.6
1
3.7
8
7
13
9
14
27.5
1.5
27.5
1
6.6
copper side view
20.6
6.6 6.6
3.7
3.75
4.4
4.4
1
2
3
5 2
7 4
6 3
8
4.1
4
5
6
7
8
9
10
11
12
13
1
3.7
14
6.3
6.7
9
10
13
11
12
14
45
55 Series - Miniature General
Purpose relays 5 - 10 - 16 A
TECHNICAL DATA
DIELECTRIC STRENGTH
1 - 2 - 3 CO
tested at leakage current
≤ 10 mA for 1 min at 50 Hz
2,000 V
2,000 V
between open contacts
1,000 V
1,000 V
between adjacent contacts
2,000 V
2,000 V
between frame and live parts
1,500 V
1,500 V
SURGE TEST (1.2/50 µs) between coil and contacts
2,500 V
ISOLATION RESISTANCE
≥ 10 · 103 MΩ
ISOLATION GROUP
B 250
MAXIMUM SWITCHING FREQUENCY
- without load
- at rated load
36,000 cycles/h
1,800 cycles/h (5 - 10 A)
600 cycles/h (16 A)
AMBIENT TEMPERATURE
(–40 ... +70)°C
20 · 106 cycles version AC
MECHANICAL LIFE
50 · 106 cycles version DC
PROTECTION CATEGORY OF ENCLOSURES
IP 40
OPERATE AND RELEASE TIME
TYPE OF DUTY
DIELECTRIC TEST
TYPE OF RELAY
46
4 CO
between coil and contacts
- pick-up time (0 to UN)
≤ 10 ms (including contact bounce)
- drop-out time (UN to 0)
≤ 15 ms (including contact bounce)
continuous
2
all-or-nothing
55 Series - Miniature General
Purpose relays 5 - 10 - 16 A
CONTACT SPECIFICATIONS
RATED CURRENT
MAXIMUM PEAK CURRENT
NOMINAL RATE IN AC1
NOMINAL RATE IN AC15
RATED VOLTAGE
MAXIMUM SWITCHING VOLTAGE
BREAKING CAPACITY IN DC1
SINGLE PHASE HP MOTOR RATING AT 250 V
CONTACT RESISTANCE: - initial
MINIMUM SWITCHING LOAD
STANDARD CONTACT MATERIAL
2 CO (SPDT)
3 CO (3PDT)
4 CO (4PDT)
10 A
10 A
5A
20 A
20 A
10 A
2,500 V A
2,500 V A
1,250 V A
500 V A
500 V A
250 V A
250 V AC
250 V AC
250 V AC
400 V AC
400 V AC
400 V AC
see diagram H 55
0.8 kW/1.2 HP
0.37 kW/0.6 HP
0.37 kW/0.6 HP
0.12 kW/0.2 HP
≤ 50 mΩ
≤ 50 mΩ
≤ 50 mΩ
≤ 50 mΩ
500 mW (10 V/5 mA) 300 mW (5 V/5 mA) 300 mW (5 V/5 mA) 300 mW (5 V/5 mA)
AgCdO
AgNi
AgNi
AgNi
F 55/1
F 55/2
CYCLES
107
CYCLES
1 CO (SPDT)
16 A
30 A
4,000 V A
750 V A
250 V AC
400 V AC
106
10
5
0
0.5
1.5
1.0
10
7
10
6
10
5
2
0
1
LOAD (kVA)
2
3
LOAD (kVA)
Contact life vs AC1 load.
4 CO relay type (5 A) at 1800 cycles/h.
Contact life vs AC1 load.
1 CO relay type (16 A) at 600 cycles/h.
2 - 3 CO relay type (10 A) at 1800 cycles/h.
K 55
H 55
A
MAX SWITCHING CURRENT (A)
B
1
C
2
10
D
6
3
4
2
1
0.6
0.4
0.8
k
0.6
0.4
1
0.2
0.1
1
k REDUCTION FACTOR
20
4
0.8
0.6
0.4
0.2
COS ϕ
20
60
100
140
180
220
DC VOLTAGE (V)
Breaking capacity for DC1 load.
1 - 1 CO type (600 cycles/h)
2 - 2 - 3 CO type (1800 cycles/h)
3 - 4 CO type (1800 cycles/h)
A = load applied to 1 contact
B = load applied to 2 contacts in series
C = load applied to 3 contacts in series
D = load applied to 4 contacts in series
Load reduction factor vs cos ϕ.
47
55 Series - Miniature General
Purpose relays 5 - 10 - 16 A
COIL SPECIFICATIONS
RATED POWER
VERSIONS:
AC - alternating current 50/60 Hz
DC - direct current
DI - DC coil with a diode in parallel
CONDUCTED DISTURBANCE IMMUNITY
(0.8 ... 1.1) UN
≤ 0.8 UN
≤ 0.5 UN
MUST DROP-OUT VOLTAGE
≥ 0.2 UN
≥ 0.1 UN
150 A
200 A
F (+155°C)
F (+155°C)
50°C/W
50°C/W
NOMINAL MAGNETOMOTIVE FORCE
THERMAL INSULATION CLASS OF WIRE
SURGE (acc. to EN 61000 - 4 - 5)
level 4 (4 kV)
THERMAL RESISTANCE
AC VERSION DATA
(R values relate to +20°C. Tolerance of R and I values: ±10 %.)
U min
(V)
4.8
9.6
19.2
38.4
48
88
100
184
192
UN (V)
6
12
24
48
60
110
125
230
240
Resistance
U max
(V)
6.6
13.2
26.4
52.8
66
121
137.5
253
264
R (Ω)
12
50
190
770
1,200
3,940
4,700
17,000
19,100
Nominal
absorption
I a UN 50 Hz
(mA)
234
117
58.3
29.2
23.3
12.7
11.2
6.3
5.8
DC VERSION DATA
(R values relate to +20°C. Tolerance of R and I values: ±10 %.)
Rated
voltage
Operating range
U min
(V)
4.8
9.6
19.2
38.4
48
88
100
UN (V)
6
12
24
48
60
110
125
R 55
Umin
(0.8 ... 1.1) UN
OPERATING RANGE
level 4 (4 kV)
Operating range
DC
1W
HOLDING VOLTAGE
BURST (acc. to EN 61000 - 4 - 4)
Rated
voltage
AC
1.5 VA
U max
(V)
6.6
13.2
26.4
52.8
66
121
137
Nominal
absorption
I a UN
(mA)
150
86
40
20
15
8.8
7.2
Resistance
R (Ω)
40
140
600
2,400
4,000
12,500
17,300
S 55/1
70
UN
TEMPERATURE RISE “∆t” (°C)
1
0.9
0.8
0.7
0.6
60
50
1.1 UN
40
UN
30
0.8 UN
20
10
0.5
-40
-20
0
20
40
60
80
100
0
120
10
DC coil min pick-up voltage vs ambient temperature.
Umin = pick-up voltage
UN = rated voltage
50
1.1 UN
40
UN
30
0.8 UN
10
50
60
60
50
40
1.1 UN
30
UN
20
0.8 UN
10
0
0
10
20
30
40
50
60
HEATING (min)
48
40
S 55/3
70
TEMPERATURE RISE “∆t” (°C)
TEMPERATURE RISE “∆t” (°C)
60
20
30
Temperature rise "∆t " vs applied voltage. DC coils.
S 55/2
70
20
HEATING (min)
AMBIENT TEMPERATURE (C°)
Temperature rise "∆t " vs applied voltage. AC - 50 Hz coils.
10
20
30
40
50
60
HEATING (min)
Temperature rise "∆t " vs applied voltage. AC - 60 Hz coils.
55 Series - Miniature General
Purpose relays 5 - 10 - 16 A
ORDERING INFORMATION
Example: a 55 series P.C.B. relay, 4 CO (4PDT) contacts, coil rated 12 V DC.
5 5
4
1
9
Coil version
3 = DC diode in parallel
to the coil (+A1/13) #
8 = AC (50/60 Hz)
9 = DC
No. of poles
1 = 1 CO (SPDT)
2 = 2 CO (DPDT)
3 = 3 CO (3PDT)
4 = 4 CO (4PDT)
Series
0
0 1 2
0
0
0
Contact material
and contact circuit
00 = Standard
20 = AgCdO
50 = AgNi + 5µm Au #
Options
Coil voltage
00 = Standard
006 =
6V
01 = Sealed (for 55.12, 55.13 and 55.14 only)
012 = 12 V
024 = 24 V
048 = 48 V
060 = 60 V
110 = 110 V
120 = 120 V AC only
230 = 230 V AC only
240 = 240 V AC only
Type
1 = P.C.B.
OPTIONS
13
14
Coil version = 3
13
14
Option = 0030
SEALED VERSION (0001)
Recommended for automatic soldering
and cleaning processes.
Not available for 1 CO (SPDT) relay.
13
14
Options = 0060 - 0070
13
14
Options = 0080 - 0090
REMOVE VENTILATION PIP
The sealed version has a removable
pip to avoid ozone accumulation when
relay is operating.
49