40 Series Miniature P.C.B. Relays 5-10-16 A A range of miniature P.C.B. relays, with 1or 2 CO (SPDT or DPDT) contacts Features include: • 1 CO (SPDT) contacts rated at 10 A or 16 A or 2 CO (DPDT) contacts rated at 5 A • NO contact circuits available • P.C.B. version • AC, DC, DC sensitive or single bistable coil versions available • Can be used with supply status, coil protection and timer modules • Sealed version available. Sealed version has special removable pip to avoid ozone accumulation when relay is operating • 8 mm between coil and contacts in accordance with VDE 0700 • Sockets and accessories: see 95 series, 99.01, 99.02, 86.10 and 86.20 • Approvals (according to type): BBJ, BEAB, CSA, DEMKO, FIMKO, GOST, IMQ, NEMKO, RINA, SEMKO, SEV, cUL, UTE, VDE TIMERS ALARM SYSTEMS INDUSTRIAL APPLIANCES INDUSTRIAL AUTOMATION BURNERS AIR CONDITIONING ELECTRONIC APPLIANCES MEDICAL EQUIPMENT IIII I II I I II I WHITE-GOODS I III AUTOMATIC GATES 9 40 Series Miniature P.C.B. Relays 5-10-16 A 40.52 40.31 GOST BEAB RINA RINA C MINIATURE P.C.B. RELAYS 10 A TYPE 40.31 1 CO (SPDT) 3.5 mm pinning TYPE 40.51 1 CO (SPDT) 5 mm pinning - Tin plated pins for P.C.B. - Standard contact material: AgNi Options: TYPE 40.31-0300 1 NO (SPST-NO) 3.5 mm pinning TYPE 40.51-0300 1 NO (SPST-NO) 5 mm pinning - Options: see coding table page 17 - Ordering information: see page 17 MINIATURE P.C.B. RELAY 5 A TYPE 40.52 2 CO (DPDT) 5 mm pinning - Tin plated pins for P.C.B. - Standard contact material: AgNi Options: TYPE 40.52-0300 2 NO (DPST-NO) 5 mm pinning - Options: see coding table page 17 - Ordering information: see page 17 12.4 29 0.4 0.4 1 copper side view 0.4 0.4 0.4 copper side view 5 5 7.5 = 1.5 7.5 = 1.5 12.4 = = A A 3 20 6 29 A: 40.31 = 3.5 mm A: 40.51 = 5 mm 10 0.4 3 20 29 6 12.4 1 5 5 25 29 C 25 12.4 GOST BEAB 40 Series Miniature P.C.B. Relays 5-10-16 A 12 14 TYPE 40.31 (1 CO - SPDT) 14 11 12 11 A1 TYPE 40.31 (1 SPST-NO) A2 A1 A2 14 14 11 11 A1 A2 A1 A2 40.61 GOST BEAB RINA 12 14 TYPE 40.51 (1 CO - SPDT) 14 C 21 MINIATURE P.C.B. RELAY 16 A TYPE 40.61 1 CO (SPDT) 5 mm pinning - Tin plated pins for P.C.B. - Standard contact material: AgCdO Options: TYPE 40.61-0300 1 NO (SPST-NO) 5 mm pinning - Options: see coding table page 17 - Ordering information: see page 17 12 21 A1 TYPE 40.51 (1 SPST-NO) A2 A1 A2 14 14 21 21 A1 TYPE 40.52 (2 CO - DPDT) 14 12.4 29 A2 A1 A2 12 14 22 11 12 24 21 22 A1 A2 14 11 24 21 A1 A2 11 24 21 A2 25 A1 5 TYPE 40.52 (2 DPST-NO) 1 0.4 14 0.4 24 11 21 A1 A2 copper side view TYPE 40.61 (1 CO - SPDT) 14 (22) 12 14 11 12 24 21 22 A1 A2 14 11 24 21 (24) 5 5 = 3 20 29 6 A1 (21) A2 12.4 1.5 7.5 = 11 TYPE 40.61 (1 SPST-NO) 14 (24) 11 (21) A1 A2 A1 A2 11 40 Series Miniature P.C.B. Relays 5-10-16 A TECHNICAL DATA DIELECTRIC STRENGTH tested at leakage current ≤ 10 mA for 1 min at 50 Hz between coil and contacts 4,000 V between open contacts 1,000 V between adjacent contacts 2,000 V between frame and live parts relay without external ground SURGE TEST (1.2/50 µs) BETWEEN COIL AND CONTACTS 6,000 V ISOLATION RESISTANCE ≥ 20 · 103 MΩ ISOLATION GROUP C 250 (1 CO) B 250 (2 CO) ≥ 8 mm between coil and contacts according to VDE 0700 ISOLATION DISTANCES MAXIMUM SWITCHING FREQUENCY - without load - at rated load 36,000 cycles/h 1,800 cycles/h (5 - 10 A) 600 cycles/h (16 A) AMBIENT TEMPERATURE (–40 ... +70)°C MECHANICAL LIFE 10 · 106 cycles version AC 20 · 106 cycles version DC PROTECTION CATEGORY OF ENCLOSURES IP 40 IP 67 (sealed version option) OPERATE AND RELEASE TIME (STANDARD) - pick-up time (0 to UN) ≤ 10 ms (including contact bounce) - drop-out time (UN to 0) ≤ 10 ms (including contact bounce) OPERATE AND RELEASE TIME (SENSITIVE) - pick-up time (0 to UN) - drop-out time (UN to 0) TYPE OF DUTY DIELECTRIC TEST TYPE OF RELAY 12 ≤ 15 ms (including contact bounce) ≤ 12 ms (including contact bounce) continuous 4 1 CO 2 2 CO all-or-nothing 40 Series Miniature P.C.B. Relays 5-10-16 A CONTACT SPECIFICATIONS 40.31 - 40.51 40.52 40.61 RATED CURRENT 10 A 5A 16 A MAXIMUM PEAK CURRENT 20 A 10 A 30 A 2,500 V A 1,250 V A 4,000 V A NOMINAL RATE IN AC1 500 V A 250 V A 750 V A RATED VOLTAGE NOMINAL RATE IN AC15 250 V AC 250 V AC 250 V AC MAXIMUM SWITCHING VOLTAGE 400 V AC 400 V AC 400 V AC BREAKING CAPACITY IN DC1 see diagram H 40 see diagram H 40 see diagram H 40 SINGLE PHASE HP MOTOR RATING AT 250 V 0.37 kW/0.6 HP 0.185 kW/0.2 HP 0.55 kW/0.8 HP CONTACT RESISTANCE: - initial ≤ 50 mΩ ≤ 50 mΩ ≤ 50 mΩ MINIMUM SWITCHING LOAD 300 mW (5 V/5 mA) 300 mW (5 V/5 mA) 300 mW (10 V/5 mA) AgNi AgNi AgCdO STANDARD CONTACT MATERIAL F 40/1 F 40/2 7 10 7 CYCLES CYCLES 10 106 106 105 105 0.50 0 0 1 1 2 3 LOAD (kVA) LOAD (kVA) Contact life vs AC1 load. Type 40.52 (5 A) at 1800 cycles/h. Contact life vs AC1 load. Type 40.31 - 40.51 (10 A) at 1800 cycles/h. Type 40.61 (16 A) at 600 cycles/h. H 40 A 1 10 2 B 6 K 40 4 1 k REDUCTION FACTOR DC BREAKING CURRENT (A) 20 3 2 1 0.6 0.4 0.2 0.8 k 0.6 0.4 1 0.1 20 4 60 100 140 DC VOLTAGE (V) Breaking capacity for DC1 load. 1 - type 40.61 at 600 cycles/h 2 - type 40.31 - 40.51 at 1800 cycles/h 3 - type 40.52 at 1800 cycles/h A - load applied to 1 contact B - load applied to 2 contacts in series 180 0.8 0.6 0.4 0.2 220 COS ϕ Load reduction factor vs cos ϕ. 13 40 Series Miniature P.C.B. Relays 5-10-16 A CONTACT SPECIFICATIONS VERSIONS: AC - alternating current 50/60 Hz DC - direct current S sensitive - DC voltage with low absorption AC DC RATED POWER 1.2 VA 0.65 W 0.5 W MINIMUM POWER 0.6 VA 0.35 W 0.25 W see diagram R 40/2 OPERATING RANGE (0.8 to 1.1) UN see diagram R 40/1 HOLDING VOLTAGE ≤ 0.8 UN ≤ 0.4 UN ≤ 0.4 UN MUST DROP-OUT VOLTAGE ≥ 0.2 UN ≥ 0.1 UN ≥ 0.1 UN NOMINAL MAGNETOMOTIVE FORCE THERMAL INSULATION CLASS OF WIRE 200 A 180 A 150 A F (+155°C) F (+155°C) F (+155°C) 68°C/W 68°C/W 68°C/W THERMAL RESISTANCE CONDUCTED DISTURBANCE IMMUNITY BURST (acc. to EN 61000 - 4 - 4) livel 4 (4 kV) SURGE (acc. to EN 61000 - 4 - 5) livel 4 (4 kV) DC VERSION DATA (0.5 W sensitive) R values relate to +20°C. Tolerance of R and I values: ± 10%. DC VERSION DATA (0.65 W standard) R values relate to +20°C. Tolerance of R and I values: ± 10%. Nominal voltage UN Umin Umax R Nominal coil absorption I V V V Ω mA Operating range Resistance Nominal voltage UN V Umin* Umax R Nominal coil absorption I V V Ω mA Operating range Resistance 5 3.65 7.5 38 130 5 3.7 8.8 50 100 6 4.4 9 55 109 6 4.4 10.5 75 80 7 5.1 10.5 75 93 7 5.1 12.2 100 70 9 6.6 13.5 125 72 9 6.6 15.8 160 56 12 8.8 18 220 55 12 8.8 21 300 40 14 10.2 21 300 47 14 10.2 24.5 400 35 18 13.1 27 500 36 18 13.2 31.5 650 27.7 21 15.3 31.5 700 30 21 15.4 36.9 900 23.3 24 17.5 36 900 27 24 17.5 42 1,200 20 28 20.5 42 1,200 23 28 20.5 49 1,600 17.5 36 26.3 54 2,000 18 36 26.3 63 2,600 13.8 48 35 72 3,500 14 48 35 84 4,800 10 60 43.8 90 5,500 11 90 65.7 135 12,500 7.2 110 80.3 165 18,000 6.1 60 43.8 105 7,200 8.3 90 65.7 157 16,200 5.5 110 80.3 192 23,500 4.7 *Umin = 0.8 UN for 40.61 AC VERSION DATA R values relate to +20°C. Tolerance of R and I values: ± 10%. 14 Sensitive DC Nominal voltage UN Umin Umax R Nominal coil absorption UN 50 Hz I V V V Ω mA Operating range Resistance 6 4.8 6.6 21 168 12 9.6 13.2 80 90 24 19.2 26.4 320 45 48 38.4 52.8 1,350 21 60 48 66 2,100 16.8 110 88 121 6,900 9.4 120 96 132 9,000 8.4 230 184 253 28,000 4.5 240 192 264 31,500 4.1 40 Series Miniature P.C.B. Relays 5-10-16 A CONTACT SPECIFICATIONS R 40/1 2.5 R 40/2 2.5 Umin UN Umin UN 1 2 1 2 1.5 1.5 1 1 2 0.5 -20 -10 0 10 20 30 40 2 50 60 70 80 90 0.5 -20 -10 AMBIENT TEMPERATURE (°C) 0 10 20 30 40 50 60 70 80 90 AMBIENT TEMPERATURE (°C) Operating range ( DC type) vs ambient temperature. 1 - Max coil voltage permitted 2 - Min pick-up voltage with coil at ambient temperature Operating range ( DC sensitive type) vs ambient temperature. 1 - Max coil voltage permitted 2 - Min pick-up voltage with coil at ambient temperature S 40/1 80 1.5 UN TEMPERATURE RISE “∆t” (°C) 70 60 50 1.2 UN 40 UN 30 20 0.73 UN 10 10 20 30 40 50 60 HEATING TIME (min) Temperature rise "∆t " vs applied voltage. DC coils. S 40/2 S 40/3 80 80 70 60 1.1 UN 50 UN 40 30 0.8 UN 20 10 0 10 20 30 40 50 60 HEATING TIME (min) Temperature rise "∆t " vs applied voltage. AC 50 Hz coils. TEMPERATURE RISE “∆t” (°C) TEMPERATURE RISE “∆t” (°C) 70 60 1.1 UN 50 UN 40 30 0.8 UN 20 10 0 10 20 30 40 50 60 HEATING TIME (min) Temperature rise "∆t " vs applied voltage. AC 60 Hz coils. 15 40 Series Miniature P.C.B. Relays 5-10-16 A COIL SPECIFICATIONS RATERD POWER 1.1 W MINIMUM POWER 0.7 W OPERATING RANGE (0.8 ... 1.1) UN NOMINAL MAGNETOMOTIVE FORCE 230 A MINIMUM IMPULSE DURATION 20 ms MAXIMUM IMPULSE DURATION continuos THERMAL INSULATION CLASS OF WIRE F (+155°C) DRIVING CIRCUIT (AC - DC) AC DC A D A B coil V~ coil RAC V— RAC ~ 1.3 · RDC D = (for example) 1N4007 A push once to pick-up A push once to pick-up B push once to drop-out B push once to drop-out AC/DC VERSION DATA (bistable) R values relate to +20°C. Tolerance of R and I values: ± 10%. Nominal voltage UN Operating range Umin Umax V V V 5 4 6 4.8 Resistance Nominal coil DC: Release absorption resistance** R I RDC Ω mA Ω 5.5 23 215 37 6.6 33 165 62 12 9.6 13.2 130 83 220 24 19.2 26.4 520 40 910 2,100 21 3,600 11,000 10 16,500 48 110 38.4 88 52.8 121 ** RDC = Resistance in DC, RAC = 1.3 x RDC 16 B RDC 40 Series Miniature P.C.B. Relays 5-10-16 A ORDERING INFORMATION Example: a 40 series P.C.B. relay with 2 CO (DPDT) contact, coil rated at 12 V AC. 4 0 5 Series 8 2 No. of poles 1 = 1 CO for 40.31 40.51 40.61 2 = 2 CO for 40.52 Coil version 6 = AC/DC bistable 7 = DC sensitive 8 = AC (50/60 Hz) 9 = DC Type 3 = 3.5 mm pinning 5 = 5 mm pinning 6 = 5 mm pinning ** not available for 40.61 # not available for bistable version ## not available for sensitive DC and bistable versions Code 0 0 0 1 2 Contact material and contact circuit 00 = Standard AgNi for 40.31, 51, 52 AgCdO for 40.61 03 = Contact NO 20 = AgCdO 40 = AgSnO2 50 = AgNi + Au (5µm)** Supply voltage 005 = 5 V DC only 006 = 6 V 007 = 7 V DC only 009 = 9 V DC only 012 = 12 V 014 = 14 V DC only 018 = 18 V DC only 021 = 21 V DC only 024 = 24 V 028 036 048 060 090 110 120 230 240 = = = = = = = = = 28 36 48 60 90 110 120 230 240 0 0 Special applications 00 = Standard 01 = Sealed version (IP67) # 03 = High temperature (+125°C) sealed version## V V V V V V V V V DC only DC only DC only AC only AC only AC only Coil type Cover colour 9 DC Direct current transparent blue cover 8 AC Alternating current at 50/60 Hz transparent orange cover 7 S Sensitive - DC with low consumption transparent blue cover 6 BS Bistable (single winding) transparent green cover OPTION SEALED VERSION Suitable for automated soldering and washing processes. REMOVABLE VENTILATION PIP Sealed version has special removable pip to avoid ozone accumulation when the relay is operating. 17 95 Series - Sockets and Accessories for 40 Series Relays A range of sockets and accessories for 40 series relays • P.C.B. version • Flammability in accordance with UL 94 • Approvals (according to type): BBJ, CSA, IMQ, SEV, cULus 18 95 Series - Sockets and Accessories for 40 Series Relays 95.15 ® C C V US P.C.B. SOCKETS TYPE 95.13 for types 40.31 - 41.31 TYPE 95.15 for types 40.51 - 40.52 - 40.61 Accessories: TYPE 095.51 metal retaining clip Accessories: TYPE 095.52 plastic retaining clip CHARACTERISTICS - LOAD: 10 A 250 V - ISOLATION RESISTANCE: ≥ 103 MΩ - DIELECTRIC STRENGTH: ≥ 2 kV AC - MATERIAL: self-extinguishing PPEm (V1) - CONNECTIONS: CuSn6 tin plated 10 3.5 30 20 3.5 20 30 3.5 7.5 3.5 13 4 13 7.5 95.13 13 4 10 7.5 30 20 5 20 30 5 5 5 13 7.5 95.15 19