ETC 6531-8110-0300

65 Series
Power Relays 20 - 30 A
A range of power relays for switching heavy duty loads (up to 7.5 kVA in AC1)
• Top and rear DIN rail mount, top and rear mount flange options
• AC or DC coils
• 3 mm gap between open contacts on NO (AC coil version), FASTON 250 (6.3 x 0.8 mm)
versions
• Approvals (according to type): IMQ, CSA, SEMKO, SEV, cUL, VDE
WHITE
GOODS
CONDITIONING
COFFEE
MACHINES
AUTOMATIC
GATES
IIII
I II I
I II I
VOLTAGE
STABILIZERS
I III
FOOTWEAR
MACHINES
87
65 Series
Power Relays 20 - 30 A
65.31
C
DOUBLE BREAKING FASTON 250 RELAY
TYPE 65.31 1 NO + 1 NC (SPDT-NC-NO) 20 A
- Flange mount with 3 to 3.5 mm Ø screws
- Tin plated brass connections (6.3 x 0.8 mm)
- Standard contact material: Ag CdO
Options:
TYPE 65.31 - 0300 1 NO (SPST-NO) 30 A
- 1.5 + 1.5 mm gap between open contacts
- Ordering information: see page 93
36.5
9.5
42
32.2
9.1
14
14
11
9.1
13.1
21
b
65.31
6.4 4
14
22
a
13
11
a
b
65.31 - 0300
3.6
88
3.5
7
52
42
3
3.6
3.5
32.2
65 Series
Power Relays 20 - 30 A
TECHNICAL DATA
DIELECTRIC STRENGTH
tested at leakage current
≤ 10 mA for 1 min at 50 Hz
between coil and contacts
2,000 V
between open contacts
1,500 V
between open contacts NO version
2,500 V
between adjacent contacts
2,500 V
between frame and live parts
2,000 V
SURGE TEST (1.2/50 µs) between coil and contacts
2,500 V
ISOLATION RESISTANCE
≥ 20 · 103 MΩ
ISOLATION GROUP
C 250
MAXIMUM SWITCHING FREQUENCY
- without load
36,000 cycles/h
- at rated load
600 cycles/h
AMBIENT TEMPERATURE
(–40 ... +50)°C
MECHANICAL LIFE
10 · 106 cycles version AC
PROTECTION CATEGORY OF ENCLOSURES
IP 40
OPERATE AND RELEASE TIME
CO
NO
≤ 20 ms (including contact bounce)
≤ 25 ms (including contact bounce)
≤ 20 ms (including contact bounce)
—
Option = +75°C
30 · 106 cycles version DC
- pick-up time (0 to UN)
- drop-out time (UN to 0)
TYPE OF DUTY
DIELECTRIC TEST
TYPE OF RELAY
continuous
2
all-or-nothing
89
65 Series
Power Relays 20 - 30 A
CONTACT SPECIFICATIONS
65.31
65.31 NO
RATED CURRENT
20 A
30 A
MAXIMUM PEAK CURRENT
40 A
50 A
5,000 VA
7,500 VA
NOMINAL RATE IN AC1
NOMINAL RATE IN AC15
1,000 VA
1,250 VA
RATED VOLTAGE
250 V AC
250 V AC
MAXIMUM SWITCHING VOLTAGE
400 V AC
400 V AC
see diagram H 65
see diagram H 65
1.1 kW/1.5 HP
1.5 kW/2 HP
BREAKING CAPACITY IN DC1
SINGLE PHASE HP MOTOR RATING
CONTACT RESISTANCE: - initial
≤ 50 mΩ
≤ 50 mΩ
MINIMUM SWITCHING LOAD
1,000 mW (10 V/10 mA)
1,000 mW (10 V/10 mA)
AgCdO
AgCdO
STANDARD CONTACT MATERIAL
F 65
20
MAX SWITCHING CURRENT (A)
5 · 10
CYCLES
H 65
30
6
5 · 105
1
10
6
4
2
1
0.4
0.2
0.1
5 · 104
1
3
5
7
KVA
B
A
0.6
20
100
140
180
VOLTAGE DC (V)
LOAD (kVA)
Breaking capacity for DC1 load at 600 cycles/h.
Load applied to 1 contact.
A - types 65.31 - 65.61
B - NO versions
Contact life vs AC1 load at 600 cycles/h.
1 - types 65.31 and 65.31-0300; 65.61 and 65.61-0300
K 65
REDUCTION FACTOR
K
1
0.8
0.6
0.4
1
0.8
0.6
0.4
COS ϕ
Load reduction factor vs cos ϕ.
90
60
0.2
220
65 Series
Power Relays 20 - 30 A
COIL SPECIFICATIONS
VERSIONS:
AC - alternating current 50/60 Hz
DC - direct current
AC
RATED POWER
DC
2.2 VA
1.3 W
OPERATING RANGE
(0.8 ... 1.1) UN
(0.8 ... 1.1) UN
HOLDING VOLTAGE
≤ 0.8 UN
≤ 0.6 UN
MUST DROP-OUT VOLTAGE
≥ 0.2 UN
≥ 0.1 UN
NOMINAL MAGNETOMOTIVE FORCE
THERMAL INSULATION CLASS OF WIRE
THERMAL RESISTANCE
CONDUCTED DISTURBANCE IMMUNITY
180 A
250 A
F (+155°C)
F (+155°C)
41°C/W
41°C/W
BURST (acc. to EN 61000 - 4 - 4)
livel 4 (4 kV)
SURGE (acc. to EN 61000 - 4 - 5)
livel 4 (4 kV)
AC VERSION DATA
R values relate to +20°C. Tolerance of R and I values: ± 10%.
Rated
voltage
Operating range
UN
Umin
V
V
U
Resistance
Nominal coil
absorption
max
R
UN 50 Hz I
V
Ω
mA
6
4.8
6.6
12
9.6
13.2
4.6
19
367
183
24
19.2
26.4
80
91.7
48
38.4
52.8
320
45.8
60
48
66
500
110
88
121
1,800
36.7
20
120
96
132
1,940
18.6
230
184
253
7,250
10.4
240
192
264
8,500
9.2
DC VERSION DATA
R values relate to +20°C. Tolerance of R and I values: ± 10%.
Rated
Resistance Nominal coil
Operating range
voltage
absorption
UN
Umin
V
V
U
max
R
V
Ω
I
mA
6
5.1
6.6
28
214
12
10.2
13.2
110
109
24
20.4
26.4
445
53.9
48
40.8
52.8
1,770
27.1
60
51
66
2,760
21.7
121
9,420
11.7
110
93.5
91
65 Series
Power Relays 20 - 30 A
COIL SPECIFICATIONS
R 65
Umin
S 65/1
1
70
TEMPERATURE RISE “∆t” (°C)
UN
0.9
0.8
0.7
0.6
60
1.1 UN
50
UN
40
30
0.8 UN
20
10
0.5
0
- 40
-20
0
20
40
60
10
80
AMBIENT TEMPERATURE (°C)
20
30
60 min
Temperature rise "∆t " vs applied voltage. DC coils.
S 65/2
S 65/3
70
70
60
60
50
1.1 UN
40
UN
30
0.8 UN
20
10
0
TEMPERATURE RISE “∆t” (°C)
TEMPERATURE RISE “∆t” (°C)
50
HEATING TIME (min)
DC coil min pick-up voltage vs ambient temperature.
Umin = pick-up voltage
UN = rated voltage
50
1.1 UN
40
UN
30
0.8 UN
20
10
0
10
20
30
40
50
60 min
HEATING TIME (min)
Temperature rise "∆t " vs applied voltage. AC 50 Hz coils.
92
40
10
20
30
40
50
60 min
HEATING TIME (min)
Temperature rise "∆t " vs applied voltage. AC 60 Hz coils.
65 Series
Power Relays 20 - 30 A
ORDERING INFORMATION
Example: a 65 series power relays with 1 CO contact with a 12 V DC coil.
6 5
Series
3
1
No. of poles
1 = 1 CO
0 1 2
9
Coil version
8 = AC (50/60 Hz)
9 = DC
Type
3 = FASTON 250,
with rear flange mount
Coil rated voltage
6V
006 =
012 = 12 V
024 = 24 V
048 = 48 V
060 = 60 V
110 = 110 V
125 = 125 V
230 = 230 V
0
0
0
0
Contact material and
contact circuit
00 = Standard
03 = NO
Light and mechanical
indicators
00 = Standard
05 = Top flange mount
07 = Top DIN rail mount
08 = Rear DIN rail mount
OPTIONS