ETC 8534A

Piezoresistive Pressure Transducer
ENDEVCO
MODEL
8534A
Model 8534A -10, -20,
-50 and -100
•
•
•
•
10 to 100 psia
300 mV Full Scale
Rugged, Subminiature
0.065 Inch Diameter
DESCRIPTION
The ENDEVCO® Model 8534A is a rugged, subminiature piezoresistive pressure transducer for measuring
absolute pressure. It has a case diameter of only 0.065
inch (1.65 mm) and is available in ranges from 10 to
100 psia full scale. Full scale output is 300 mV with high
overload capability and high frequency response.
Actual size
.050 (1.27) DIA. X 27/33 (686/838)
4 CONDUCTOR CABLE
ENDEVCO pressure transducers feature an active fourarm strain gage bridge diffused into a sculptured silicon
diaphragm for maximum sensitivity and wideband
frequency response. Self-contained hybrid temperature
compensation provides stable performance over the wide
temperature range of 0°F to +200°F (-18°C to +93°C).
ENDEVCO transducers also feature excellent linearity
(even to 3X range), high shock resistance, and high
stability during temperature transients.
.450
(11.43)
TINNED LEADS
.063/.067 DIA.
(1.60/1.70)
SILVER PLATED SHIELD
PRESSURE
VESSEL
BONDED IN PLACE
WITH RTV
CASE
The Model 8534A can be installed in locations which are
difficult to reach. Its small size permits flush mounting on
curved surfaces. Its high sensitivity combined with small
size and high resonance makes the 8534A suitable for use
on small-scale models in wind tunnels.
RED + IN
NO RTV
.10 MIN.
(2.5)
NOMINAL
.30
(7.6)
GRN + OUT
.071/.075 DIA.
(1.80/1.90)
BLK - IN
ENDEVCO Model 136 Three-Channel System, Model
4430A Signal Conditioner, or Model 68207 BCAS™
Computer Controlled Systems are recommended as signal conditioner and power supply.
MOUNTING DETAIL
WHT - OUT
STANDARD TOLERANCE
INCHES
(MILLIMETERS)
.XX = +/- .03 (.X = +/- .8)
.XXX = +/- .010 (.XX = +/- .25)
SPECIFICATIONS
CERTIFIED PERFORMANCE: All specifications assume +75°F (+24°C) and 10 Vdc excitation unless otherwise stated. The following parameters
are 100% tested. Calibration data, traceable to the National Institute of Standards and Technology (NIST), is supplied.
RANGE [1]
SENSITIVITY [1]
COMBINED: NON-LINEARITY, NON REPEATABILITY,
PRESSURE HYSTERESIS [2]
Non-Linearity, Independent
Non-Repeatability
Pressure Hysteresis
ZERO MEASURAND OUTPUT [3]
ZERO SHIFT AFTER 3X RANGE
THERMAL ZERO SHIFT
From 0°F to +200°F (-18°C to +93°C)
THERMAL SENSITIVITY SHIFT
From 0°F to +200°F (-18°C to +93°C)
UNITS
psia
mV/psia
8534A-10
0 -10
30 ±10
-20
0 - 20
15 ±5
-50
0 - 50
6 ±2
-100
0 - 100
3 ±1
% FSO RSS Max
% FSO Typ
% FSO Typ
% FSO Typ
mV Max
±% 3X FSO Max
(Typ)
1.0
0.5
0.1
0.1
±10
0.2
(0.02)
0.50
0.2
0.1
0.1
±10
0.2
(0.02)
0.50
0.2
0.1
0.1
±10
0.2
(0.02)
0.50
0.2
0.1
0.1
±10
0.2
(0.02)
±% FSO Max
3
3
3
3
±% Max
4
4
4
4
ENDEVCO
Piezoresistive Pressure Transducer
MODEL
8534A
SPECIFICATIONS—continued
TYPICAL PERFORMANCE CHARACTERISTICS: The following parameters are established from testing of sample units.
RESONANCE FREQUENCY
NON-LINEARITY AT 3X RANGE
THERMAL TRANSIENT RESPONSE PER
ISA-S37.10, PARA. 6.7, PROCEDURE l [4]
PHOTOFLASH RESPONSE [5]
WARM-UP TIME [6]
ACCELERATION SENSITIVITY
Longitudinal
Lateral
BURST PRESSURE (Diaphragm)
ELECTRICAL
FULL SCALE OUTPUT
SUPPLY VOLTAGE [5]
ELECTRICAL CONFIGURATION
POLARITY
RESISTANCE
Input
Output
Isolation
NOISE
MECHANICAL
CASE MATERIAL
CABLE, INTEGRAL
DEAD VOLUME
MOUNTING
WEIGHT (excluding lead wires)
ENVIRONMENTAL
MEDIA
TEMPERATURE [7]
VIBRATION
ACCELERATION
SHOCK
HUMIDITY
Units
Hz
% 3X FSO
psi/°F
psi/°C
Equiv. psi
ms
8534A-10
140 000
1.0
0.001
0.002
0.1
1
-20
200 000
1.0
0.003
0.005
0.5
1
-50
370 000
1.0
0.005
0.009
1.0
1
-100
410 000
0.5
0.01
0.02
1.0
1
Equiv. psi/g
Equiv. psi/g
psi Min
0.00015
0.00006
100
0.0002
0.00005
150
0.0003
0.0002
200
0.0006
0.0004
400
300 ±100 mV at 10.0 Vdc
10.0 Vdc recommended, 18 Vdc maximum
Active four-arm piezoresistive bridge
Positive output for increasing pressure
2000 ±800 ohms
1600 ±500 ohms
100 megohms minimum at 50 Volts; leads to case, leads to shield, shield to case
5 microvolts rms typical, dc to 50 000 Hz; 50 microvolts rms maximum, dc to 50 000 Hz
Nickel -Iron Alloy
Four conductor No. 36 AWG Teflon® insulated leads, braided shield, Teflon jacket
30 ±3 inches, (760 ±76 mm)
0.000015 cubic inches (0.0002 cc)
Bond into #49 drill hole (1.85 mm) using RTV, such as DOW CORNING Silastic® 738;
RTV is not permitted within 0.10 inch (2.5 mm) of unit's face
0.08 gram (cable weighs 3.6 grams/meter)
Internal seals are epoxy and are compatible with clean dry gas media. Media is exposed
to nickel-iron alloy. Parylene C, and epoxy. For use in water or corrosive media, contact
the factory for modifications and installation precautions which may be taken to extend
service life.
-65°F to +250°F (-54°C to +121°C)
1000 g pk
1000 g
20 000 g, 100 microsecond haversine pulse
Isolation resistance greater than 100 megohms at 50 volts, per MIL-STD-202E, Method
103B, Test Condition B
CALIBRATION DATA
Data supplied for all parameters in Certified Performance section. Optional calibrations available for all parameters in Typical Performance
section.
OPTIONAL ACCESSORY
25034
4 CONDUCTOR SHIELDED CABLE
NOTES
1. 1 psi = 6.895 kPa = 0.069 bar.
2. FSO (Full Scale Output) is defined as transducer output
change from 0 psia to + full scale pressure.
3. Zero Measurand Output (ZMO) is the transducer output with
0 psia applied.
4. Use of excitation voltages other than 10.0 Vdc requires manufacture and calibration at that since thermal errors increase
with high excitation voltages.
5. Per ISA-S37.10, Para 6.7, Procedure II.
6. Warm-up time is defined as elapsed time from excitation voltage "turn on" until the transducer output is within ±1% of reading accuracy.
7. Units can be compensated over any 200°F (93°C) span from
-65°F to +250°F (-54°C to +121°C)
NOTE: Tighter specifications are available on special order.
Continued product improvement necessitates that Endevco reserve the right to modify these specifications without notice. Endevco maintains a program of constant
surveillance over all products to ensure a high level of reliability. This program includes attention to reliability factors during product design, the support of stringent
Quality Control requirements, and compulsory corrective action procedures. These measures, together with conservative specifications have made the name Endevco
synonymous with reliability.
ENDEVCO CORPORATION, 30700 RANCHO VIEJO ROAD, SAN JUAN CAPISTRANO, CA 92675 USA (949) 493-8181 fax (949) 661-7231
0298