ETC 9422CGJ50

Motor control
Accurate and reliable control
of motors
Te Sys range provide you more simplicity, compactness,
openness and flexibility
... so man y evolutions and new items to aid your productivity.
TeSys
For a new start!
A range
of simple,
compact and
advanced
components
for power control
and protection.
New horizons are opening up to you. Increase your productivity adopt our solutions which help to simplify setting-up.
Motor starters
b Ready-to-use component combinations,
designed to work together in perfect harmony.
b Saf e operation and level of coordination
guaranteed by a major manufacturer.
Power circuit control
b A wide range of components.
b Solutions for a variety of power control
applications: lighting, capacitor switching,
heating, changeover contactor pairs, resistive
loads, upstream protection.
The essential
guide
A simplified
selection guide
enabling you to
quickly select
motor starters.
5/0
Contents
Motor control components
TeSys contactors ................................................................. 5/2 to 5/9
b Contactors , models K, D, F
TeSys protection components ...................................... 5/10 to 5/21
b Manual motor star ters
b Switch-disconnector-fuses
b Thermal overload relays
b Electronic thermal overload relays
b Multifunction protection relays
b Switch disconnectors Mini Vario and Vario
TeSys starters ................................................................. 5/22 to 5/25
b Self-protected starter, U-Line
b Solid state overload relay system, U-Line
5
IEC type industrial control relays .................................. 5/26 to 5/29
b TeSys type CA2K, CA3K and CA4K
b TeSys type CAD
TeSys U - LU9
Control increases in power
NEMA type ....................................................................... 5/30 to 5/49
b Contactors and starters
b Combination starters
b Solid state overload relays Motor Logic®
b Definite purpose contactors
b Lighting contactors
b Manual starters and switches
b Accessories
b Industrial control relays
b Circuit breaker operating mechanisms
b Disconnect switches
Simply Smart benefits
Introducing the 1st intellig ent starter
capable of integrating motor control,
control and changeo ver functions in a
unit 45 mm wide! Simple in its modular
format, it is also open to standard buses
and can monitor your applications via the
web.
Applications
b Industr y: ideal solution when the motor
starter needs to be decentralized in the
machine or the process
5/1
TeSys
Contactors
K-line
0.5–10 Hp
Connections
■ screw clamp terminals
Rated operational current
Ie max AC-3 (Ue - 440V)
6A
9A
Ie AC-1 (θ - 40° C)
-
20 A
12 A
-
Rated operational power
220/240 V
2 Hp
3 Hp
4 Hp
in category AC3
380/400 V–415/440 V
3 Hp
5 Hp
7.5 Hp
660/690 V–500 V
4 Hp
5 Hp
5 Hp
Contactor type (1)(2)
AC
LC1K06••
LC1K09••
LC1K12••
DC
LP1K06•• or LP4K06••
LP1K09 or LP4K09••
LP1K12 or LP4K12••
Reversing contactor type (2)
AC
LC2K06
LC2K09
LC2K12
with mechanical interlock
DC
LP2K06 or LP5K06
LP2K09 or LP5K09
LP2K12 or LP5K12
■ spring terminals
Add the figure 3 before the voltage code. Example LC1K0610•• becomes LC1K06103••
■ slip-on connectors, 1 x 6.35 or 2 x 2.8
5
Add the figure 7 before the voltage code. Example LC1K0610•• becomes LC1K06107••
■ solder pins for printed circuit boards
Add the figure 5 before the voltage code. Example LC1K0610•• becomes LC1K06105••
(1) Basic catalog number, to be completed by adding 01 for N.C. auxiliary contact, or 10 for N.O. auxiliary contact.
(2) Basic catalog number to be completed by adding the coil voltage. Example (including auxiliary contact) LC1RO601G7.
Standard control circuit voltages
AC supply
Contactors LC1K (0.8–1.15 Uc) (0.85–1.1UC)
Volts
12
20
24
36
42
48
110
115
120
127
200/208
220/230
230
230/240
50/60 Hz
J7
Z7
B7
C7
D7
E7
F7
FE7
G7
FC7
L7
M7
P7
U7
Volts
256
277
380/400
400
400/415
440
480
500
575
600
660/690
50/60 Hz
W7
UE7
Q7
V7
N7
R7
T7
S7
SC7
X7
Y7
Example of complete catalog number LC1K0910P7.
DC supply
Contactors LP1K (0.8–1.15 Uc)
Volts
12
20
24
36
48
60
72
100
110
125
155
174
200
220
230
240
250
Code
JD
ZD
BD
CD
ED
ND
SD
KD
FD
GD
PD
QD
LD
MD
MPD
MUD
UD
Coil with integral suppression device available, add 3 to the code required. Example JD3
Low consumption
Contactors LP4K (0.7–1.30 Uc), coil suppression as standard
Volts
12
20
24
48
72
110
120
Code
JW3
ZW3
BW3
EW3
SW3
FW3
GW3
Example of complete catalog number LC1K0910BD.
For other versions, please consult with your localSchneider Electric /
5/2
Square D sales office: visit www.us.telemanique.com.
TeSys
K-line
Auxiliary contact blocks
■ instantaneous, screw clamp connections
■ for LC1, LP1K, LP4
Composition
2 N.O.
-
2 N.C.
Catalog number
LA1KN20
LA1KN02
■ for LC1, LP1K
1 N.O. 1 N.C.
4 N.O.
3 N.O. 1 N.C.
2 N.C. 2 N.C.
1 N.O. 3 N.C.
-
LA1KN11
LA1KN40
LA1KN31
LA1KN22
LA1KN13
LA1KN04
4 N.C.
■ electronic time delay
Relay outputs, with common point changeover contact, AC or DC 24–48, 2 A maximum
Control voltage 0.85–1.1Uc
Maximum switching capacity 250 VA or 150 W
Operating temperature -10 to + 60°C
Reset time: 1.5 s for 0.5 s after the time delay period
Type
On-delay
Timing range
1–30 s
Composition
1
Voltage
AC or DC 24–48 V
AC 110–240
Reference
LA2KT2E
LA2KT2U
5
Suppressor modules
For LC1, LP1K
Type
Varistor (AC and DC)
Voltage
12–24 V
32–48 V
50–129 V
130–250 V
Diode (DC) + zener
12–24 V
32–48 V
RC (AC)
110–250 V
Catalog number
LA4KE1B
LA4KE1E
LA4KE1FC
LA4KE1UG
LA4KC1B
LA4KC1E
LA4KA1U
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/3
TeSys
Contactors
D-line
0.5–125 Hp
Connections
■ screw clamp terminals or connectors
Rated operational voltage
Rated operational current
690 V
Ie max AC-3 (Ue - 440V)
9A
Ie AC-1 (θ - 60° C)
25 A
12 A
18 A
25 A
32 A
32 A
40 A
50 A
Rated operational power
220/240 V
3 Hp
4 Hp
5 Hp
7.5 Hp
10 Hp
in category AC3
380/400 V
5 Hp
7.5 Hp
10 Hp
15 Hp
20 Hp
415/440 V
5 Hp
7.5 Hp
12 Hp
15 Hp
20 Hp
500 V
7.5 Hp
10 Hp
13 Hp
20 Hp
25 Hp
660/690 V
7.5 Hp
10 Hp
13 Hp
20 Hp
25 Hp
1000 V
-
-
-
-
-
Contactor type (1)
LC1D09
LC1D12
LC1D18
LC1D25
LC1D32
Reversing contactor type * with mechanical interlock
LC2D09
LC2D12
LC2D18
LC2D25
LC2D32
■ spring terminals (1)
5
Add the figure 3 before the voltage code. Example LC1D09P7 becomes LC1093P7
■ ring tongue terminals (2)
Add the figure 6 before the voltage code. Example LC1D09P7 becomes LC1096P7
■ slip-on connectors (3) 2 x 6.35 (power) and 1 x 6.35 (control) up to D12 only
Add the figure 9 before the voltage code. Example LC1D09P7 becomes LC1099P7
(1) Basic catalog number to be completed by adding the coil voltage. Example: LC1D09P7.
(1) LC1D093P7
(3) LC1D099P7
(2) LC1D096P7
Standard control circuit voltages
AC supply
Volts
24
42
48
110
115
220
230
240
380
400
415
440
500
Contactors LC1D09–D50 (coils D115 and D150 with integral suppression device fitted as standard)
50/60 Hz
B7
D7
E7
F7
FE7
M7
P7
U7
Q7
V7
N7
R7
-
50 Hz
B5
D5
E5
F5
FE5
M5
P5
U5
Q5
V5
N5
R5
S5
60 Hz
B6
-
E6
F6
-
M6
-
U6
Q6
-
-
R6
-
12
24
36
48
60
72
110
125
220
250
440
Contactors LC1D40–D115
DCsupply
Volts
Contactors LC1D09–D38 (coils with integral suppression device fitted as standard)
U 0.7–1.25 Uc
JD
BD
CD
ED
ND
SD
FD
GD
MD
UD
RD
U 0.85–1.1 Uc
JD
BD
CD
ED
ND
SD
FD
GD
MD
UD
RD
U 0.75–1.2 Uc
JW
BW
CW
EW
-
SW
FW
-
MW
-
-
SD
FD
GD
MD
UD
RD
Contactors LC1D40–D95
Contactors LC1D115 and D150 (coils with integral suppression device fitted as standard)
U 0.75–1.2 Uc
-
BD
-
ED
ND
Low consumption
Contactors LC1D09–D38 (coils with integral suppression device fitted as standard)
Volts DC
5
12
20
24
48
110
120
250
U 0.7–1.25 Uc
AL
JL
ZL
BL
EL
FL
ML
UL
Example of complete catalog number LC1D09P7.
For enclosed version of d-Line starters up to 80A, reference catalog 8502CT9901.
For other versions, please consult with your localSchneider Electric /
5/4
Square D sales office: visit www.us.telemanique.com.
TeSys
D-line
1000 V on AC supply, 690 V on DC supply
38 A
40 A
50 A
60 A
80 A
65 A
80 A
95 A
12 Hp
15 Hp
20 Hp
25 Hp
30 Hp
30 Hp
40 Hp
50 Hp
25 Hp
25 Hp
30 Hp
40 Hp
50 Hp
60 Hp
75 Hp
100Hp
25 Hp
30 Hp
30/40 Hp
50 Hp
60 Hp
60 Hp
75 Hp
100 Hp
25 Hp
30 Hp
40 Hp
50 Hp
75 Hp
75 Hp
100 Hp
125Hp
125Hp
125 A
115 A
150 A
200 A
25 Hp
40 Hp
44 Hp
50 Hp
60 Hp
60 Hp
100 Hp
-
30 Hp
40 Hp
50 Hp
60 Hp
60 Hp
100 Hp
125 Hp
LC1D38
LC1D40
LC1D50
LC1D65
LC1D80
LC1D95
LC1D115
LC1D150
LC2D38
LC2D40
LC2D50
LC2D65
LC2D80
LC2D95
LC2D115
LC2D150
5
Mounting accessories for 3-pole reversing contactors
2 identical contactors with screw clamp terminals or connectors, horizontally mounted
Mechanical interlock
Set of connections
Mechanical interlock
LAD9R1V
included
LC1D40–D65
LA9D6569
LA9D4002
LC1D80 and D95 (AC)
LA9D8069
LA9D4002
LC1D80 and D95 (DC)
LA9D8069
LA9D8002
LC1D115 and D150
LA9D11569
LA9D11502
LC1D09–D38
LA99R1
included
LC1D40–D65
LA9D6569
LA9D50978
LC1D80 and D95 (AC)
LA9D8069
LA9D50978
LC1D80 and D95 (DC)
LA9D8069
LA9D80978
For use on contactor
Catalog number
Standard control circuit voltages
LC1D40–D65 3P AC or DC, LC1D65 4P AC, LC1D65 4P DC
LA6DK10•
BEFMQ
LC1D80–D150 3P AC, LC1D80 and D115 3P AC, LC1D115 4P DC
LA6DK20•
BEFMQ
LC1D09–D38 AC or DC, LC1DT20–DT40 AC or DC
LA66K10•
BEFMQ
■ with an electrical interlocking kit for the contactors
LC1D09–D38
■ with integral electrical interlocking
■ without electrical interlocking
Mechanical latch blocks
Clip-on front mounting, manual or electrical unlatching control
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/5
TeSys
Contactors
D-line
0.5–125 Hp
Auxiliary contact blocks
■ instantaneous, for connection by screw clamp terminals
■ time delay
■ front mounting
Composition
Catalog number
N.O. N.C.
Composition
Catalog number
N.O. N.C.
Composition
Catalog number
N.O. N.C.
■ side mounting
■ front mounting
Composition
Catalog number
Type
On-delay
Range
Catalog number
N.O. N.C.
1
-
LADN10
1
1
LADN11
2
2
LADN22
1
1
LAD8N11
-
1
LADN01
2
-
LADN20
1
3
LADN13
2
-
LAD8N20
-
2
LADN02
-
2
LAD8N02
4
-
LADN40
-
4
LADN04
3
1
LADN31
Off-delay
0.1–3 s
LADT0
0.1–30 s
LADT2
10–180 s
LADT4
0.1–3 s
LADR0
0.1–30 s
LADR2
10–180 s
LADR4
5
Maximum number of auxiliary contacts that can be fitted
Contactors
Instantaneous auxiliary contact blocks
Time delay
Type
Number of poles and size
Side mounting
Front mounting
1 contact
2 contacts
4 contacts
AC
3P LC1D09–D38
1 on LH side and
-
1
or 1
LC1D40–D95 (50/60 Hz)
1 on each side or
2
and 1
or 1
or 1
LC1D40–D95 (50 or 60 Hz)
1 on each side and 2
and 1
or 1
or 1
LC1D115 and D150
1 on LH side
-
and 1
or 1
or 1
1 on LH side
-
1
or 1
or 1
LC1D65 and D80
1 on each side or
1
or 1
or 1
or 1
LC1D115
4P LC1DT20–DT40
DC
or 1
1 on each side and 1
or 1
or 1
or 1
3P LC1D09–D38
-
-
1
or 1
or 1
LC1D40–D95
-
1
or 1
or 1
or 1
LC1D115 and D150
1 on LH side and
-
1
or 1
or 1
4P LC1DT20–DT40
Low Consumption
Front mounting
-
-
1
or 1
or 1
LP1D65 and D80
-
2
and 1
or 1
or 1
LC1D115
1 on each side
-
and 1
or 1
or 1
3P LC1D09–D38
-
-
1
-
-
4P LC1DT20–DT40
-
-
1
For other versions, please consult with your localSchneider Electric /
5/6
Square D sales office: visit www.us.telemanique.com.
TeSys
D-line
Suppressor modules
Varistors (peak limiting)
Protection provided by limiting the transient voltage to 2 Uc max.
Maximum reduction of transient voltage peaks.
Slight increase in drop-out time (1.1 to 1.5 times the normal time)
Mounting
Clip-on
Screw clamp
For use with contactor
Type
Rating
VAC
Catalog number
VDC
D09–D38 (3P)
12–24 V
-
LAD4VE
DT20–DT40 (4P)
50–127 V
-
LAD4VG
D40–D115 (3P)
110–240 V
-
LAD4VU
24–48 V
-
LA4DE2E
and
50–127 V
-
LA4DE2G
D65–D115 (4P)
110–250 V
-
LA4DE2U
LA4DE3E
D40–D115 (3P)
-
24–48 V
and
-
50–127 V
LA4DE3G
D65–D115 (4P)
-
110–250 V
LA4DE3U
-
24–250 V
LA4DC3U
5
Diodes
No overvoltage or oscillating frequency.
Increase in drop-out time (6 to 10 times the normal time).
Polarised component.
Screw clamp
D40–D95 (3P)
D65 and D80 (4P)
Bidirectional peak limiting diode
Protection provided by limiting the transient voltage to 2 Uc max.
Maximum reduction of transient voltage peaks.
Clip-on
Screw clamp
D09–D38 (3P)
24 V
-
LAD4TB
DT20–DT40 (4P)
72 V
-
LAD4TS
D40–D95 (3P)
24 V
-
LA4DB2B
D65 and D80 (4P)
72 V
-
LA4DB2S
D40–D95 (3P)
-
24 V
LA4DB3B
D65 and D80 (4P)
-
72 V
LA4DB3S
RC circuits (Resistor-Capacitor)
Effective protection for circuits highly sensitive to "high frequency" interference.
For use only in cases where the voltage is virtually sinusoidal, i.e. less than - 5% total harmonic distortion.
Voltage limited to 3 Uc max and oscillating frequency limited to 400 Hz max.
Slight increase in drop-out time (1.2 to 2 times the normal time)
Clip-on
Screw fixing
D09–D38 (3P)
12–24 V
-
LAD4RCE
DT20–DT40 (4P)
110–240 V
-
LAD4RCU
D40–D150 (3P)
24–48 V
-
LA4DA2E
and
50–127 V
-
LA4DA2G
D65–D115 (4P)
110–240 V
-
LA4DA2U
380–415 V
-
LA4DA2N
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/7
TeSys
Contactors
F-line
30–900 Hp
Rated operational current
5
Ie max AC-3 (Ue - 440V)
185 A
225 A
265 A
330 A
Ie AC-1 (θ - 40° C)
275 A
315 V
350 A
400 A
Rated operational voltage
1 000 V
1 000 V
1 000 V
1 000 V
Number of poles
3 or 4
3 or 4
3 or 4
3 or 4
Rated operational power
220/240 V
75 Hp
75 Hp
100 Hp
125 Hp
in category AC3
380/400 V
125 Hp
150 Hp
200 Hp
250 Hp
415 V
125 Hp
150 Hp
175 Hp
220 Hp
440 V
125 Hp
150 Hp
175 Hp
300 Hp
500 V
150 Hp
175 Hp
250 Hp
300 Hp
660/690 V
150 Hp
175 Hp
250 Hp
350 Hp
1000 V
125 Hp
125 Hp
200 Hp
250 Hp
Contactor type (1)
LC1F185
LC1F225
LC1F265
LC1F330
Reversing contactor type (1)
LC2F185
LC2F225
LC2F265
(1) Basic catalog number to be completed by adding the coil voltage code. Example: LC1F18567.
Standard control circuit voltages
AC supply
Volts
24
48
110
115
120
208
220
230
240
380
400
415
440
50 Hz (coil LX1)
B5
E5
F5
FE5
-
-
M5
P5
U5
Q5
V5
N5
-
60 Hz (coil LX1)
-
E6
F6
-
G6
L6
M6
-
U6
Q6
-
-
R6U7
40–400 Hz (coil LX9)
-
E7
F7
FE7
G7
L7
M7
P7
U7
Q7
V7
N7
R7
B7
E7
F7
FE7
G7
L7
M7
P7
U7
Q7
V7
N7
R7
-
E7
F7
FE7
G7 (1)
L7
M7
P7
U7
Q7
V7
N7
R7
-
-
F7
FE7
F7
L7
M7
P7
U7
Q7
V7
N7
R7
-
-
FE7
FE7
FE7
-
P7
P7
P7
V7
V7
V7
V7Y7
24
48
110
125
220
230
250
400
440
BD
ED
FD
GD
MD
MD
UD
-
RD
-
ED
FD
GD
MD
-
UD
-
RD
-
-
FD
GD
MD
-
UD
-
RD
-
-
FW
FW
MW
MW
-
QW
-
Contactors LC1F115–F225(0.85–1.1UC)
Contactors LC1F265–F330U7
40–400 Hz (coil LX1)
Contactors LC1F400–F630U7
40–400 Hz (coil LX1)
Contactor LC1F780U7
40–400 Hz (coil LX1)
Contactor LC1F800U7
40–400 Hz (coil LX1)
DC supply
Volts
Contactors LC1F115–F330(0.85–1.1UC)
(coil LX4F)
Contactors LC1F400–F630(0.85–1.1UC)
(coil LX4F)
Contactor LC1F780(0.85–1.1UC)
(coil LX4F)
Contactor LC1F800(0.85–1.1UC)
(coil LX4F)
Example: For a 630 A contactor with a 110 VAC coil, order LC1F630F7.
(1) F7 for LC1F630.
For other versions, please consult with your localSchneider Electric /
5/8
Square D sales office: visit www.us.telemanique.com.
TeSys
F-line
400 A
500 A
630 A
780 A
800 A
500 A
700 A
1 000 A
1 600 A
1 000 A
1 000 V
1 000 V
1 000 V
1 000 V
1 000 V
2, 3 or 4
2, 3 or 4
2, 3 or 4
3 or 4
3
150 Hp
200 Hp
300 Hp
350 Hp
400 Hp
300 Hp
400 Hp
450 Hp
600 Hp
600 Hp
350 Hp
450 Hp
500 Hp
500 Hp
600 Hp
400 Hp
400 Hp
600 Hp
500 Hp
600 Hp
300 Hp
475 Hp
600 Hp
600 Hp
600 Hp
450 Hp
450 Hp
600 Hp
600 Hp
600 Hp
250 Hp
450 Hp
600 Hp
600 Hp
600 Hp
LC1F400
LC1F500
LC1F630
LC1F780
LC1F800
For customer assembly
5
Auxiliary contact blocks
■ instantaneous
Composition
Catalog number
N.O. N.C.
Composition
Catalog number
N.O. N.C.
Composition
Catalog number
N.O. N.C.
dust&dampprotectedcontacts
■ time delay 1N.O. + 1 N.C.
Composition
Catalog number
Type
On-delay
Range
Catalog number
N.O. N.C.
1
-
LADN10
1
1
LADN11
2
2
LADN22
2
-
-
-
LA1DX20
-
1
LADN01
2
-
LADN20
1
3
LADN13
2
2
-
-
LA1DY20
-
2
LADN02
0.1–3 s
LADT0
0.1–30 s
LADT2
4
-
LADN40
2
-
2
-
LA1DZ40
10–180 s
LADT4
-
4
LADN04
2
-
1
1
LA1DZ31
1–30 s
LADS2
3
1
LADN31
2
2
LADC22
Off-delay
0.1–3 s
LADR0
0.1–30 s
LADR2
10–180 s
LADR4
Mounting accessories for 3-pole reversing contactors for motor control
2 identical contactors, horizontally mounted
Mechanical interlock with an electrical interlocking kit for the contactors
Contactor type
Set of connections
Mechanical interlock
LC1F115
LA9FF976
LA9FF970
LC1F150
LA9F15076
LA9FF970
LC1F185
LA9FG976
LA9FG970
LC1F225
LA9F22576
LA9FG970
LC1F265
LA9FH976
LA9FJ970
LC1F330
LA9FJ976
LA9FJ970
LC1F400
LA9FJ976
LA9FJ970
LC1F500
LA9FK976
LA9FJ970
LC1F630 or LC1F800
LA9FL976
LA9FL970
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/9
TeSys
Manual motor starters
Type GVZME
and GV2P
0.1–30 Hp
Manual motor starters GV2ME and GV2P for connection by screw clamp terminals
GV2ME with pushbutton control, GV2P control by rotary knob
Horsepower ratings of 3-phase motors 50/60 Hz
200 V
5
230 V
460 V
575 V
Setting range
Magnetic
of thermal
tripping
trips
current
A
A
Catalog Number
Push button
Rotary Handle
-
-
-
-
0.1–0.16
1.5
GV2ME01
GV2P01
-
-
-
-
0.16–0.25
2.4
GV2ME02
GV2P02
-
-
-
-
0.25–0.40
5
GV2ME03
GV2P03
-
-
-
-
0.40–0.63
8
GV2ME04
GV2P04
-
-
0.5
0.5
0.63–1
13
GV2ME05
GV2P05
-
-
0.75
1
1–1.6
22.5
GV2ME06
GV2P06
0.5
0.5
1
1.5
1.6–2.5
33.5
GV2ME07
GV2P07
0.75
1
2
3
2.5–4
51
GV2ME08
GV2P08
1.5
1.5
3
5
4–6.3
78
GV2ME10
GV2P10
2
3
5
7.5
6–10
138
GV2ME14
GV2P14
3
3
10
10
9–14
170
GV2ME16
GV2P16
5
5
10
15
13–18
223
GV2ME20
GV2P20
5
7.5
15
20
17–23
327
GV2ME21
GV2P21
5
7.5
15
20
20–25
327
GV2ME22
GV2P22
10
10
20
30
24–32
416
GV2ME32
GV2P32
Thermal-magnetic circuit-breakers GV2ME for connection by spring terminals
Add the number 3 to the end of the catalog number. Example GV2ME223 (available up to GV2ME22)
Thermal-magnetic circuit-breakers GV2ME for connection by spring terminals
Add the figure 3 to the end of the catalog number. Example GV2ME223 (available up to GV2ME22)
Fuse holder—30 A rated, type CC or KTK-R fuses
Catalog Number
With screw terminals
LS1D30
With spring terminals
LS1D303
Auxiliary pole (screw terminals;
LA8D324
mount on left or right side)
For other versions, please consult with your localSchneider Electric /
5/10
Square D sales office: visit www.us.telemanique.com.
TeSys
Type GVZME
and GV2P
Accessories
Combination block
For mounting on
LC1K or LP1K
LC1D09–D38
LAD31 and LC1D09–D38
GV2AF01
GV2AF3
GV2AF4
Sets of 3-pole busbars
63 A
Pitch
45 mm
54 mm
72 mm
Number of tap-offs
2
GV2G245
GV2G254
GV2G272
3
GV2G345
GV2G354
4
GV2G445
GV2G454
5
GV2G472
GV2G554
Protective end cover
For unused busbar outlets
GV1G10
Terminal blocks
For supply to one or more GV2G busbar sets
connection from the top
can be fitted with current limiter GV1L3 (GV2ME and GV2P)
GV1G09
GV1G05
Padlocking
In “On” and “Off ” position
In “Off ” position
Handle
black
red
Legend plate
blue
yellow
GV2AP01
GV2AP02
5
Padlockable external operator for GV2P (150 to 290 mm)
IP 54
Padlocking device
For all GV2 devices
For use with up to 6 padlocks (padlocks not supplied) Ø 6 mm shank max
GV2V03
Add-on blocks
Contact blocks
Contact types
N.O. or N.C.
N.O. + N.C.
N.O. + N.O.
GVAE1
GVAE11
GVAE20
GVAN11
GVAN20
(fault) + N.C.
N.C. + N.O.
Instantaneous auxiliary contacts
Mounting
C.O. common
point
front
LH side
Fault signalling contact + instantaneous auxiliary contact
LH side
GVAD1010
GVAD1001
GVAD0110
GVAD0101
Short-circuit signalling contact
LH side
GVAM11
Electric trips
Undervoltage or shunt trips (1)
Side mounting (1 block on RH side of circuit-breaker)
50 Hz
60 Hz
Voltage (AC)
24 V
GVA•025
GVA•026
48 V
GVA•055
GVA•056
100 V
GVA•107
GVA•107
100–110 V
110–115 V
GVA•115
120–127 V
GVA•125
GVA•115
127 V
200 V
GVA•207
GVA•207
200–220 V
220–240 V
GVA•225
GVA•226
380–400 V
GVA•385
GVA•386
415–440 V
GVA•415
415 V
(1) Undervoltage trips: replace the
GVA•116
GVA•416
• with U, shunt trips: replace the • with S
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/11
TeSys
Manual motor starters
Type GV3ME
0.5–60 Hp
Manual motor starters GV3ME for connection by screw clamp terminals
Pushbutton control
Horsepower ratings of 3-phase motors 50/60 Hz
200 V
Setting range of thermal trips
Catalog Number
230 V
460 V
575 V
A
-
-
0.75
1
1–1.6
GV3ME06
0.5
0.5
1
1.5
1.6–2.5
GV3ME07
0.75
1
2
3
2.5–4
GV3ME08
1.5
1.5
3
-
4–6
GV3ME10
2
3
5
7.5
6–10
GV3ME14
3
5
10
10
10–16
GV3ME20
5
7.5
15
20
16–25
GV3ME25
10
10
30
30
25–40
GV3ME40
20
20
40
60
40–63
GV3ME63
20
25
50
60
56–80
GV3ME80
5
Add-on blocks
Contact blocks
Instantaneous auxiliary contacts (1 per breaker)
Normal early break type contacts
N.C. + N.O.
N.O. + N.O.
N.C. + N.O. + N.O.
N.O. + N.O. + N.O.
N.O. + N.O. (1)
N.C. + N.O. (1)
GV3A01
GV3A02
GV3A03
GV3A05
GV3A06
GV3A07
Fault signalling contact
Normal early break type contacts
N.C.
N.O.
GV3A08
GV3A09
Electric trips
Voltage
50 Hz
110, 120, 127 V
220, 240 V
380, 415 V
60 Hz
120, 127 V
277 V
440, 480 V
Undervoltage trip
GV3B11
GV3B22
GV3B38
Shunt trip
GV3D11
GV3D22
GV3D38
Padlocking device
Start button (for bare device)
GV1V02
(1) + 2 volt free terminals
For other versions, please consult with your localSchneider Electric /
5/12
Square D sales office: visit www.us.telemanique.com.
TeSys
Manual motor starters
1–120 Hp
Type GV7R
Manual motor starters GV7R for connection by screw clamp terminals
Control by rocker lever
Horsepower ratings of 3-phase motors 50/60 Hz
Setting range of thermal trips
Catalog Number
230 V
460V
575 V
A
5
10
15
12–20
GV7RE20
5
10
15
12–20
GV7RS20
7.5
15
20
15–25
GV7RE25
7.5
15
20
15–25
GV7RS25
10
30
30
25–40
GV7RE40
10
30
30
25–40
GV7RS40
15
30
40
30–50
GV7RE50
30
60
75
48–80
GV7RE80
30
60
75
48–80
GV7RS80
30
75
100
60–100
GV7RE100
30
75
100
60–100
GV7RS100
50
100
150
90–150
GV7RE150
50
100
150
90–150
GV7RS150
75
150
200
132–220
GV7RE220
75
150
200
132–220
GV7RS220
5
Add-on blocks
Contact blocks
Auxiliary contacts Contact type
C.O.
GV7AE11
Thermal or magnetic fault discrimination
24–48 VAC/DC or 24–72 VDC
110–240 VAC/DC
GV7AD111
GV7AD112
Electric trips
Voltage
50/60 Hz
48 V
110–130 V
200–240 V
380–440 V
Undervoltage trip (1)
GV7AU055
GV7AU107
GV7AU207
GV7AU387
GV7AU525
Shunt trip (1)
GV7AS055
GV7AS107
GV7AS207
GV7AS387
GV7AS525
50 Hz
525 V
(1) For mounting of a GV7AD or a GV7AU or AS
Accessories
Terminal shields IP 405
Supplied with the sealing accessory
GV7AC01
Phase barriers
used when fitting of shields is impossible
GV7AC04
Insulating screens
Ensure insulation between the connections and the backplate
GV7AC05
Kit for combination with contactor
Allowing link between the circuit-breaker and the contactor
LC1F115 to F185
LC1F225 and F26
LC1D115 and D150
GV7AC06
GV7AC07
GV7AC08
Rotary handles
Handle
black
red
Legend plate
black
yellow
■ direct
IP 40
GV7AP03
GV7AP04
■ extended
IP 55
GV7AP01
GV7AP02
IP 43
GV7AP05
Conversion accessory
for mounting on enclosure door
Locking device
For starter not fitted with a rotary handle
GV7V01
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/13
TeSys
Switch-disconnector-fuses
GS1
0–1250 A
GS1 fusible disconnect switch 30–800 A
Catalog number
GS1DDU3
GS1DU3
GS1EERU20
GS1EERU30
GS1EEU3
Switch Type
Compact fused
Compact fused
Fused
Fused
Fused
Fuses
CC
J
CC
CC
CC
Amps
30
30
30
30
30
Poles
3
3
2
3
3
Operator Style
Thru-the-door
Thru-the-door
Side handle
Side handle
Thru-the-door
Max. HP 3 Phase:
kW/hp at 240V
5.5/7.5
5.5/7.5
n/a
5.5/7.5
5.5/7.5
kW/hp at 480V
11/15
11/15
n/a
11/15
11/15
kW/hp at 600V
15/20
15/20
n/a
15/20
15/20
5
LK3 non-fused disconnect switch 30–1200 A
Catalog number
LK3GU3
LK3GU3
LK3JU3
LK3MU3 (1)
LK3QU3 (1)
Switch Type
Compact Non-fused
Non-fused
Non-fused
Non-fused
Non-fused
Amps
30
60
100
200
400
Poles
3
3
3
3
3
Operator Style
Thru-the-door
Thru-the-door
Thru-the-door
Thru-the-door
Thru-the-door
Max. HP 3 Phase:
kW/hp at 240V
5.5.7.5
11/15
22/30
45/60
90/125
kW/hp at 480V
11/15
22/30
45/60
90/125
185/250
kW/hp at 600V
15/20
37/50
55/75
110/150
250/350
(1) Ter minal lugs must be ordered separately.
Auxiliary early break and/or signalling contacts
Switch rating
30–200 A
Contact type
1 N.O.
1 N.C.
50–400 A
1 C.O.
2 C.O.
600–800A
1 C.O.
2 C.O.
50–400 V
1 N.C. + 1 N.O. 2 N.C. + 2 N/O
Standard contacts
GS1AM110
GS1AM101
GS1AM1
GS1AM2
GS1AMU3
GS1AMU4
GS1AN11
GS1AN22
For other versions, please consult with your localSchneider Electric /
5/14
Square D sales office: visit www.us.telemanique.com.
TeSys
GS1
GS1EU3
GS1GU3
GS1JU3 (1)
GS1MU3 (1)
GS1QU3 (1)
GS1SU3 (1)
Fused
Fused
Fused
Fused
Fused
Fused
GS1TU3 (1)
Fused
J
J
J
J
J
J
L
30
60
100
200
400
600
800
3
3
3
3
3
3
3
Thru-the-door
Thru-the-door
Thru-the-door
Thru-the-door
Thru-the-door
Thru-the-door
Thru-the-door
5.5/7.5
11/15
22/30
45/60
90/125
185/250
185/250
11/15
22/30
45/60
90/125
185/250
370/500
370/500
15/20
37/50
55/75
110/150
250/350
370/500
370/500
5
LK3SU3 (1)
LK3TU3 (1)
LK3UU3 (1)
LK3WU3
Non-fused
Non-fused
Non-fused
Non-fused
600
800
1000
1200
3
3
3
3
Thru-the-door
Thru-the-door
Thru-the-door
Thru-the-door
150/200
185/250
185/250
185/250
300/400
370/500
370/500
370/500
250/350
370/500
370/500
370/500
(1) Terminal lugs must be ordered separately.
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/15
TeSys
Thermal overload relays
K-line
0.11–11.5 A
Thermal overload relays, model k
adjustable from 0.11 to 12 A
Connection by screw clamp terminals, direct mounting on contactors LC1K, manual or automatic reset
5
Relay setting range
Fuses to be used with selected relay (international applications only) (5)
Class 10 A
aM
gG
BS88
Catalog number
0.11–0.16 A
0.25 A
0.5 A
-
LR2K0301
0.16–0.23 A
0.25 A
0.5 A
-
LR2K0302
0.23–0.36 A
0.5 A
1A
-
LR2K0303
0.36–0.54 A
1A
1.6 A
-
LR2K0304
0.54–0.8 A
1A
2A
-
LR2K0305
0.8–1.2 A
2A
4A
6A
LR2K0306
1.2–1.8 A
2A
6A
6A
LR2K0307
1.8–2.6 A
2A
6A
10 A
LR2K0308
2.6–3.7 A
4A
10 A
16 A
LR2K0310
3.7–5.5 A
6A
16 A
16 A
LR2K0312
5.5–8 A
8A
20 A
20 A
LR2K0314
8–11.5 A
10 A
25 A
20 A
LR2K0316
Thermal overload relays for use on class 10 A unbalanced loads: for above catalog numbers LR2K0305 to LR2K0316 only, replace the prefix LR2 with LR7.
Example LR7K0310.
Accessories
Prewiring kit
Allowing direct connection of the N.C. contact
For use on
of relay LRD01–35 or LR3D01–D35 to the contactor
LC1D09–D18
LAD7C1
LC1D25–D38
LAD7C2
For clip-on mounting on 35 mm mounting rail (AM1-DP200)
LRD01–35 and LR3D01–D35
LAD7B10
or screw fixing
LRD3•••, LR3D3•••, LRD35••
LA7D3064 (2)
For independent mounting of the relay
LR2K••••
LA7K0064
LRD3•••, LR3D3•••, LRD35••
LA7D3058
LRD01–35 and LR3D01–D35
LAD703• (4)
All relays except LRD01–35 and LR3D01–D35
LA7D03• (4)
Terminal blocks (1)
Terminal block adapter
For mounting a relay beneath an LC1D115 or D150 contactor
Stop or electrical reset
Remote(3)
Tripping or electrical reset device
Remote(3)
(1) Terminal blocks are supplied with terminals protected against direct finger contact and scre ws in the open “ready-to-tighten” position.
(2) To order a terminal block for connection by lug-clamps, the catalog n umber becomes LA7D30646.
(3) The time for which the coil of remote tripping or electrical resetting device LA76D03 or LAD703 can remain energized depends on its rest time: 1 s pulse duration with
9 s rest time; maximum pulse duration of 20 s with a rest time of 300 s. Minimum pulse time 200 ms.
(4) Catalog number to be completed by adding the code indicating the control circuit voltage.
(5) Short circuit protection for U.S. applications: circuit breakers selected in accordance with NEC and local codes; fuses selected with maximum of 400% full load current.
Standard control circuit voltages
AC supply
Volts
12
24
48
96
110
220/230
380/400
415/440
50/60 Hz. Consumption, inrush and sealed < 100 VA
-
B
E
-
F
M
Q
N
J
B
E
DD
F
M
-
-
DC supply
Consumption, inrush and sealed < 100 W
For other versions, please consult with your localSchneider Electric /
5/16
Square D sales office: visit www.us.telemanique.com.
TeSys
Thermal overload relays
0.1–140 A
D-line
Thermal overload relays, model d
adjustable from 0.1 to 140 A
Compensated relays with manual or automatic reset, with relay trip indicator, for AC or DC
Relay setting range
Fuses to be used with selected relay (international applications only) (5)
aM
Class 10 A
Class 20 A
gG
With contactor
Catalog number
BS88
0.10–0.16 A
0.25 A
2A
-
LC1D09–D38
LRD01
0.16–0.25 A
0.5 A
2A
-
LC1D09–D38
LRD02
0.25–0.40A
1A
2A
-
LC1D09–D38
LRD03
0.40–0.63 A
1A
1.6 A
-
LC1D09–D38
LRD04
0.63–1 A
2A
4A
-
LC1D09–D38
LRD05
1–1.7 A
2A
4A
6A
LC1D09–D38
LRD06
1.6–2.5 A
4A
6A
10 A
LC1D09–D38
LRD07
2.5–4 A
6A
10 A
16 A
LC1D09–D38
LRD08
4–6 A
8A
16 A
16 A
LC1D09–D38
LRD10
5.5–8 A
12 A
20 A
20 A
LC1D09–D38
LRD12
7–10 A
12 A
20 A
20 A
LC1D09–D38
LRD14
9–13 A
16 A
25 A
25 A
LC1D12–D38
LRD16
12–18 A
20 A
35 A
32 A
LC1D18–D38
LRD21
16–24 A
25 A
50 A
50 A
LC1D25–D38
LRD22
23–32 A
40 A
63 A
63 A
LC1D25–D38
LRD32
30–38 A
50 A
80 A
80 A
LC1D32 and D38
LRD35
17–25 A
25 A
50 A
50 A
LC1D40–D95
LRD3322
23–32 A
40 A
63 A
63 A
LC1D40–D95
LRD3353
30–40 A
40 A
100 A
80 A
LC1D40–D95
LRD3355
LRD3357
37–50 A
63 A
100 A
100 A
LC1D40–D95
48–65 A
63 A
100 A
100 A
LC1D50–D95
LRD3359
55–70 A
80 A
125 A
125 A
LC1D50–D95
LRD3361
63–80 A
80 A
125 A
125 A
LC1D65 and D95
LRD3363
80–104 A
100 A
160 A
160 A
LC1D80 and D95
LRD3365
80–104 A
125 A
200 A
160 A
LC1D115 and D150 LRD4365
95–120 A
125 A
200 A
200 A
LC1D115 and D150 LRD4367
110–140 A
160 A
250 A
200 A
LC1D150
LRD4369
80–104 A
100 A
160 A
160 A
(1)
LRD33656
95–120 A
125 A
200 A
200 A
(1)
LRD33676
110–140 A
160 A
250 A
200 A
(1)
LRD33696
6A
10 A
16 A
LC1D09–D32
LRD1508
LRD1510
4–6 A
8A
16 A
16 A
LC1D09–D32
5.5–8 A
12 A
20 A
20 A
LC1D09–D32
LRD1512
7–10 A
16 A
20 A
25 A
LC1D09–D32
LRD1514
9–13 A
16 A
25 A
25 A
LC1D12–D32
LRD1516
12–18 A
25 A
35 A
40 A
LC1D18–D32
LRD1521
17–25 A
32 A
50 A
50 A
LC1D25 and D32
LRD1522
23–28 A
40 A
63 A
63 A
LC1D25 and D32
LRD1530
25–32 A
40 A
63 A
63 A
LC1D25 and D32
LRD1532
17–25 A
32 A
50 A
50 A
LC1D40–D95
LR2D3522
23–32 A
40 A
63 A
63 A
LC1D40–D95
LR2D3553
30–40 A
50 A
100 A
80 A
LC1D40–D95
LR2D3555
37–50 A
63 A
100 A
100 A
LC1D50–D95
LR2D3557
48–65 A
80 A
125 A
100 A
LC1D50–D95
LR2D3559
55–70 A
100 A
125 A
125 A
LC1D65–D95
LR2D3561
63–80 A
100 A
160 A
125 A
LC1D80 and D95
LR2D3563
5
(1) Separate mounting. Screw clamp terminal connections or connectors. For spring terminal connections on LRD01 to LRD22, add 3 to the end of the catalog number.
Example: LRD01 becomes LRD013. For lug-clamp connections, add 6 to the end of the catalog number . Example: LRD01 becomes LRD016. For thermal overload relays for
use with class 10 A unbalanced loads, with connection by screw clamp terminals, change the prefix in the catalog n umbers above from LRD (except LRD4•••) to LR3D.
Example LRD01 becomes LR3D01.
(5) Short circuit protection for U.S. applications: circuit breakers selected in accordance with NEC and local codes; fuses selected with maximum of 400% full load current.
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/17
5
TeSys
Electronic thermal overload relays
F-line
60–630 A
For use with contactor
LC1D
Motor current
60–150 A
30–630 A
Catalog number, to be completed
LR9D
LR9F
Relay setting range
Fuse to be used with selected relay
For mounting
LC1F
Compensated and differential
(international application) (3)
beneath contactor LC1
aM
gG
Class 10
Class 20
or not with alarm
60–100
100
160
D115 and D150
LR9D5367
LR9D5567
90–150
160
250
D115 and D150
LR9D5369
LR9F5569
30–50
50
80
F115–F185
LR9F5357
LR9F5557
LR9F57
48–80
80
125
F115–F185
LR9F5363
LR9F5563
LR9F63
60–100
100
200
F115–F185
LR9F5367
LR9F5567
LR9F67
90–150
160
250
F115–F185
LR9F5369
LR9F5569
LR9F69
132–220
250
315
F185–F400
LR9F5371
LR9F5571
LR9F71
200–330
400
500
F225–F500
LR9F7375
LR9F7575
LR9F75
300–500
500
800
F225–F500
LR9F7379
LR9F7579
LR9F79
380–630
630
800
F400–F630 and F800
LR9F7381
LR9F7581
LR9F81
Class 10 or 20
Accessories
Remote control
Function
Reset
Electrical reset (1)
LA7D03• (2)
Reset by flexible cable (length 0.5 m)
LA7D305
Adapter for door interlock mechanism
Stop and/or Reset
LA7D1020
Operating head for pushbutton
Spring return
ZA2BL639
ZA2BL432
Rod with snap-off end
Adjustable from 17 to 120 mm
ZA2BZ13
Insulated terminal blocks
For relays LR9F5•57, F5•63, F5•67, F5•69, F57, F63, F67 and F69
Set of 2 blocks
LA9F103
(1) The time for which the coil of remote electrical reset device LA7D03 can remain energized depends on its rest time: 1 s pulse with 9 s rest time; 5 s pulse duration with
30 s rest time; 10 s pulse duration with 90 s rest time: maximum pulse duration 20 s with rest time of 300 s. Minimum pulse time: 200 ms.
(2) Catalog number to be completed by adding the coil voltage code, see page 5/27.
(3) Short circuit protection for U.S. applications: circuit breakers selected in accordance with NEC and local codes; fuses selected with maximum of 400% full load current.
For other versions, please consult with your localSchneider Electric /
5/18
Square D sales office: visit www.us.telemanique.com.
TeSys
Electronic protection relays for use
with PTC thermistor probes
LT3, LT6
0–800 A
For use with contactor
LC1-D or LC1-F
Motor current
No limit
Basic reference, to be completed
LT3S
3-pole multifunction protection relays
Operational current
A
5
0.2–1. 1–5
LT6P0M005FM
Protection units with automatic reset with thermistor short-circuit detection
■ without fault memory
Connection
by cage connectors
AC 50/60 Hz
DC
Voltage
Output contact
Catalog number
115 V
N.C.
LT3SE00F
230 V
N.C.
LT3SE00M
24 V
N.C.
LT3SE00F
On front panel: fault and voltage signalling indicator
AC 50/60 Hz
115/230 V
N.C. + N.O.
LT3SA00M
DC
24/48 V
N.C. + N.O.
LT3SA00ED
AC 50/60 Hz or DC
24–230 V
2 C.O.
LT3SA00MW
400 V
N.C. + N.O.
LT3SM00V
24/48 V
N.C. + N.O.
LT3SM00E
115/230 V
N.C. + N.O.
LT3SM00M
DC
24/48 V
N.C. + N.O.
LT3SM00ED
AC 50/60 Hz or DC
24–230 V
2 C.O.
LT3SM00MW
■ with fault memory
On front panel: fault and voltage signalling indicator, Test and Reset button
AC 50/60 Hz
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
LT3
LT6
5/19
Vario
Protection components 12–175 A
Switch disconnectors
Type
Mini-Vario for standard applications
Mounting door
Backplate mounting in enclosure
Handle color / Front plate
Red / Yellow
Front plate dimensions(mm)
60 x 60
60 x 60
Mounting
Ø 22.5 mm
Ø 22.5 mm
Degree of protection
IP 20
IP 20
Rated operational voltage (Ue)
600 V
Thermal current in open air (Ith)
Black / Black
Red / Yellow
600 V
10/12 A
VCDN12
VBDN12
VCCDN12
16/20 A
VCDN20
VBDN20
VCCDN20
5
Type
Vario for high performance applications
Mounting door
Backplate mounting in enclosure
Handle color/ Front plate
Red / Yellow Black / Black Red / Yellow Black / Black Red / Yellow
Front plate dimensions
60 x 60 mm
60 x 60 mm
90 x 90 MM 60 x 60 mm
90 x 90 mm
Mounting
Ø 22.5 mm
4 screws
4 screws
4 screws
Degree of protection
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
Rated operational voltage (Ue)
600 V
600 V
600 V
600 V
600 V
600 V
Thermal current in open air :UL/IEC (A)
Ø 22.5 mm 4 screws
10/12 A
VCD02
VBD02
VCF02
VBF02
–
VCCD02
VCCF02
–
16/20 A
VCD01
VBD01
VCF01
VBF01
–
VCCD01
VCCF01
–
20/25 A
VCD0
VBD0
VCF0
VBF0
–
VCCD0
VCCF0
–
20/32 A
VCD1
VBD1
VCF1
VBF1
–
VCCD1
VCCF1
–
25/40 A
VCD2
VBD2
VCF2
VBF2
–
VCCD2
VCCF2
–
45/63 A
–
–
VCF3
VBF3
–
–
VCCF3
–
63/80 A
–
–
VCF4
VBF4
–
–
VCCF4
–
100/125 A
–
–
–
–
VCF5
–
–
VCCF5
110/175 A
–
–
–
–
VCF6
–
–
VCCF6
For other versions, please consult with your localSchneider Electric /
5/20
Square D sales office: visit www.us.telemanique.com.
Vario
Add-on modules
For mini-Vario
For Vario
Main pole modules
Rating:UL/IEC (A)
10/12 A
16/20 A
10/12 A
16/20 A
20/25 A
20/32 A
25/40 A
45/63 A
63/80 A
Catalog number
VZN12
VZN20
VZ02
VZ01
VZ0
VZ1
VZ2
VZ3
VZ4
Neutral pole module with early make and late break contacts
Rating
12–20 A
12–40 A
63 and 80 A
125 and 175 A
Catalog number
VZN11
VZ11
VZ12
VZ13
VZN14
VZ14
VZ15
VZ16
Earthing module
Catalog number
Auxiliary contact block modules
Contact types
N.O.
N.C.
N.O. + N.C.
N.O. + N.O.
Catalog number
VZN05
VZN06
VZ7
VZ20
5
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/21
TeSys
Self protected starter
U-line
0–32 A
Power base
for D.O.L. star ter
■
Connection by screw clamp terminals
Non reversing
■
Catalog number Current rating
Reversing
Catalog number Current rating
Operational voltage
200/208 V
230/240 V
460 V
575/600 V
Horseposer rating (UL ratings)
3
3
7.5
10
LUB12
12 A
LU2B12••
12 A
10
10
20
25
LUB32
32 A
LU2B32••
32 A
5
Add-on blocks
Contact blocks
Signalling
Contact
■ status of starter-controller power poles
N.O. (53-54)
■ fault
N.C. (95-96)
■ control handle in position O
N.C. (95-96)
N.O. (17-18)
1
1
N.O. (97-98)
N.O. (17-18)
Connection
Item
1
■ screw clamp terminals
1+2
LUA1D11
LUA1C11
1
LUA1C20
1
■ without connections
1
LUA1D110
LUA1C110
LUA1C200
1
Auxiliary contact blocks
■ screw clamp terminals
3
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
2
-
1
1
-
2
LUFN20
LUFN11
LUFN02
Modules
■ parallel wiring
LUFC00
■ alarm
LUFW10
■ communication
As-i
Modbus
ASILUFC5
LULC032
■ indication of motor load
4–20 mA
LUFV2
■ fault differentiation and reset
manual reset
automatic reset
LUFDH11
LUFDA10
For other versions, please consult with your localSchneider Electric /
5/22
Square D sales office: visit www.us.telemanique.com.
TeSys
U-line
Control units
■ standard
Class 10
Setting range
Clip-in mounting
0.15–0.6
12 and 32
LUCAX6••
0.35–1.4
12 and 32
LUCA1X••
1.25–5
12 and 32
LUCA05••
3–12
12 and 32
LUCA12••
4.5–18
32
LUCA18••
8–32
32
LUCA32••
■ 3-phase
■ single-phase
3-phase
12 and 32
LUCBX6••
LUCCX6••
12 and 32
LUCB1X••
LUCC1X••
LUCD1X••
12 and 32
LUCB05••
LUCC05••
LUCD05••
12 and 32
LUCB12••
LUCC12••
LUCD12••
32
LUCB18••
LUCC18••
LUCD18••
LUCB32••
LUCC32••
LUCD32••
on power base
■ advanced
For motor type
Class 10
32
■ multifunction
Class 20
LUCDX6••
5
Class 5 to 35
12 and 32
LUCMX6BL
12 and 32
LUCM1XBL
12 and 32
LUCM05BL
12 and 32
LUCM12BL
32
LUCM18BL
32
LUCM32BL
Basic catalog number to be completed by adding the voltage code (1)
Parameter entry, monitoring of
parameter values and
consultation of logs are carried
out:
„ either on the front panel, using
the built-in display window/
keypad,
„ or via an operator terminal,
„ or via a PC or a PDA with
PowerSuite software,
„ or remotely, via a Modbus
communication bus.
Programming of the product via
the keypad requires a 24 Vdc
auxiliary power supply.
Standard control circuit voltages (for other voltages, please consult your Regional Sales Office)
Volts
24
48–72
110–240
DC
BL
-
-
AC
B
-
-
AC/DC
-
ES(1)
FU (2)
(1) 48–72 VDC, 48 VAC. (2) 110–220 VDC, 110–240 VAC.
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/23
TeSys
Solid state overload relay system
0–800 A
U-line
Above 32 A, the U-line Solid state overload relay system provides a motor starter management
solution identical to that provided by TeSys U-line starter-controller .
Used in conjunction with a short-circuit protection device and a contactor, it provides a motor starter
whose functions are the same as those of a TeSys U-line self protected star ter and, in particular,
provides motor starter overload protection and control functions.
It consists of a control unit whose adjustment range is compatible with the secondary of current
transformers, plus a control base which also allows fitment of a function module or a communication
module . It requires a 24 VDC external power supply.
Control bases
For use with contactors
Current transformers (auxiliary supply voltage 24 VDC)
5
Connection
screw
Control
screw
LUTM10BL TeSys model D
Control units
For 3-phase motors
Setting range
■ advanced
■ multifunction
Class 10
Class 20
LUCBT1BL
LUCDT1BL
Class 5 to 30
0.35–1.05
LUCMT1BL
For other versions, please consult with your localSchneider Electric agency/
5/24
Square D sales office: visit www.us.telemanique.com.
TeSys
U-line
Accessories
Module
■ alarm
LUFW10
■ communication
5
Modbus
LULC033
■ indication of motor load
4–20 mA
LUFV2
Current transformers
Operational current
■ primary
30
50
100
200
400
800
■ secondary
LUTC0301
LUTC0501
LUTC1001
LUTC2001
LUTC4001
LUTC8001
For other versions, please consult with your local Schneider Electric agency/
Square D sales office: visit www.us.telemanique.com.
5/25
IEC type
industrial
control relays
TeSys Type CA2K, CA3K and CA4K
CA2KN40••
CA2KN403••
CA3KN407••
CA4KN405•••
Control relays
■ Mounting on 35 mm DIN 3 track or 4 screw direct mounting
Control Circuit
■ Screws in open “ready-to-tighten” position
Supply
Type of Termination
Contact Configuration Catalog number (1)
Consumption
N.O.
■ NEMA A600, Q600
■ IEC AC15, DC13
AC
4.5 VA
AC
4.5 VA
AC
5
screw clamp
spring terminals
4.5 VA
AC
Slip-on 1 x 6.35 or 2 x 2.8
4.5 VA
DC
solder pins for printed circuit board
3W
DC
screw clamp
3W
DC
spring terminals
3W
DC
Slip-on 1 x 6.35 or 2 x 2.8
3W
solder pins for printed circuit board
N.C.
4
0
CA2KN40••
3
1
CA2KN31••
2
2
CA2KN22••
4
0
CA2KN403••
3
1
CA2KN313••
2
2
CA2KN223••
4
0
CA2KN407••
3
1
CA2KN317••
2
2
CA2KN227••
4
0
CA2KN405••
3
1
CA2KN315••
2
2
CA2KN225••
4
0
CA3KN40••
3
1
CA3KN31••
2
2
CA3KN22••
4
0
CA3KN403••
3
1
CA3KN313••
2
2
CA3KN223••
4
0
CA3KN407••
3
1
CA3KN317••
2
2
CA3KN227••
4
0
CA3KN405••
3
1
CA3KN315••
2
2
CA3KN225••
Low consumption control relays
■ Compatible with programmable controller outputs
4
0
CA4KN40•••
3
1
CA4KN31•••
■ Wide range coil (70 to 130% Uc), suppressor fitted as standard
2
2
CA4KN22•••
■ Mounting on 35 mm DIN 3 track or 4 screw direct mounting
4
0
CA4KN403•••
3
1
CA4KN313•••
2
2
CA4KN223•••
4
0
CA4KN407•••
3
1
CA4KN317•••
2
2
CA4KN227•••
4
0
CA4KN405•••
3
1
CA4KN315•••
2
2
CA4KN225•••
■ LED indicator incorporated
DC
■ Screws in open “ready-to-tighten” position
1.8 W
DC
screw clamp
1.8 W
DC
spring terminals
1.8 W
DC
Slip-on 1 x 6.35 or 2 x 2.8
1.8 W
solder pins for printed circuit board
(1) Complete the catalog number by adding the proper voltage code from the table below. Example: CA4KN227BW3.
CA2-K control relays (0.8–1.15 Uc) (0.85–1.1UC)
Volts AC, 50/60 Hz 12
24
36
42
48
110
120
127
208
220/230
230
230/240
380/400
400
400/415
440
480
500
660/690
Code
B7
C7
D7
E7
F7
G7
FC7
L7
M7
P7
U7
Q7
V7
N7
R7
T7
S7
Y7
J7
Up to and including 240 V. Coil with integral suppression device a vailable: add 2 to the code required. Example: J72.
CA3-K control relays (0.8–1.15 Uc)
Volts DC
12
20
24
36
48
60
72
100
110
125
200
220
230
240
250
Code
JD
ZD
BD
CD
ED
ND
SD
KD
FD
GD
LD
MD
MPD
MUD
UD
Coil with integral suppression device available: add 3 to the code required. Example: JD3
CA4-K, low consumption control relays (wide range coil : 0.7–1.3 Uc)
Volts DC
12
24
48
72
Code
JW3
BW3
EW3
SW3
For additional options and information, reference catalog 8501CT0101.
For other versions, please consult with your localSchneider Electric agency/
5/26
Square D sales office: visit www.us.telemanique.com.
IEC type
industrial
control relays
Instantaneous auxiliary contact blocks
■ Clip-on front mounting, 1 block per control relay
Type of Connection
Contact Configuration
■ Auxiliary contact module not suitable for safety circuits
screw clamp
spring terminals
Slip-on 1 x 6.35 or 2 x 2.8
Catalog number
N.O.
N.C.
2
0
LA1KN20
0
2
LA1KN02
1
1
LA1KN11
4
0
LA1KN40 (1)
3
1
LA1KN31 (1)
2
2
LA1KN22 (1)
1
3
LA1KN13 (1)
0
4
LA1KN04 (1)
2
0
LA1KN203
0
2
LA1KN023
1
1
LA1KN113
4
0
LA1KN403 (1)
3
1
LA1KN313 (1)
2
2
LA1KN223 (1)
1
3
LA1KN133 (1)
0
4
LA1KN043 (1)
2
0
LA1KN207
0
2
LA1KN027
1
1
LA1KN117
4
0
LA1KN407 (1)
3
1
LA1KN317 (1)
2
2
LA1KN227 (1)
1
3
LA1KN137 (1)
0
4
LA1KN047 (1)
5
(1) Not to be used on CA4KN relays
Electronic time delay contact blocks
■ Relay output, with common point changeo ver contact, 240 VAC / VDC, 2 A maximum.
■ Control voltage: 0.85–1.1 Uc.
■ Maximum switching capacity: 250 VA or 150 W.
■ Operating temperature: - 10 to + 60 °C (+14° F to 140° F).
■ Reset time: 1.5 sec. dur ing the time delay period, 0.5 sec. after the time delay.
■ Clip-on front mounting, 1 block per control relay
Voltage
Type
Timing Range
Composition C.O.
Catalog number
24–48 VAC / VDC
On-delay
1–30 seconds
1
LA2KT2E
110–240 VAC
On-delay
1–30 seconds
1
LA2KT2U
For additional options and information, reference catalog 8501CT0101.
For other versions, please consult with your local Schneider Electric agency/
Square D sales office: visit www.us.telemanique.com.
5/27
IEC type
industrial
control relays
TeSys Type CAD
CAD32••
CAD326••
CAD503••
Instantaneous control relays
Terminal Type
Number of Contacts
screw clamp
5
spring terminal
5
ring tongue
5
Contact Configuration
Catalog n umber (1)
N.O.
N.C.
5
0
CAD50••
3
2
CAD32••
5
0
CAD503••
3
2
CAD323••
5
0
CAD506••
3
2
CAD326••
(1) Complete the catalog number by adding the proper voltage code from the table below. Example:CAD50G7.
AC 50/60 Hz coil
5
Volts
12
24
48
120
208
240
277
480
600
Code
J7
B7
E7
G7
LE7
U7
W7
T7
X7
DC coil (coils have built in suppression as standard)
Volts
12
24
36
48
60
72
110
125
220
250
440
Code
JD
BD
CD
ED
ND
SD
FD
GD
MD
UD
RD
DC low consumption coil (coils have built in suppression as standard)
Volts
5
12
24
48
72
Code
AL
JL
BL
EL
SL
For additional options and information, reference catalog 8501CT0101.
For other versions, please consult with your localSchneider Electric agency/
5/28
Square D sales office: visit www.us.telemanique.com.
IEC type
industrial
control relays
Instantaneous auxiliary contact blocks (for use in normal operation environments)
Number of Contacts
2
2
2
4
4
Max. Number per Device (clip-on mounting)
Front
Left Side Only
1
–
1
–
1
1
Termination Type
Contact Composition
N.O.
Screw Clamp
–
Spring Terminal
1 (not for DC devices) Screw Clamp
–
Screw Clamp
–
Spring Terminal
Catalog number
N.C.
2
0
LADN20
1
1
LADN11
0
2
LADN02
2
0
LADN203
1
1
LADN113
0
2
LADN023
2
0
LAD8N20
1
1
LAD8N11
0
2
LAD8N02
4
0
LADN40
3
1
LADN31
2
2
LADN22
1
3
LADN13
0
4
LADN04
4
0
LADN403
3
1
LADN313
2
2
LADN223
1
3
LADN133
0
4
LADN043
4
1
–
Screw Clamp
2
2
LADC22 (4)
4
1
–
Spring Terminal
2
2
LADC223 (4)
5
Instantaneous auxiliary contact blocks with dust and damp protected contacts (for use in particularly harsh industrial environments)
Number of Contacts
2
4
Max. Number per Device
Front Mounting
Contact Composition
Sealed
(1)
N.O.
N.C.
2
–
–
Normal
N.O.
N.C.
–
–
LA1DX20
1
–
2
–
–
–
LA1DX02
2
–
2
–
–
LA1DY20
2
–
–
2
–
LA1DZ40
2
–
–
1
1
LA1DZ31
1
Catalog Number
(1) Grounding terminal points (2 terminals jumpered together ; see diagram on page 8 of Catalog 8501CT0101).
Time delay auxiliary contact blocks
Number and Type
of Contacts
1 N.C. and 1 N.O.
1 N.C. and 1 N.O.
1 N.C. and 1 N.O.
1 N.C. and 1 N.O.
Max. Number per Device
Front Mounting
1
1
1
1
Time Delay Type
On-Delay
On-Delay
Off-Delay
Off-Delay
Termination Type
screw clamp
spring terminal
screw clamp
spring terminal
Range
Catalog Number
0.1 to 3 sec. (2)
LADT0
0.1 to 30 sec.
LADT2
10 to 180 sec.
LADT4
1 to 30 sec. (3)
LADS2
0.1 to 3 sec. (2)
LADT03
0.1 to 30 sec.
LADT23
10 to 180 sec.
LADT43
1 to 30 sec. (3)
LADS23
0.1 to 3 sec. (2)
LADR0
0.1 to 30 sec.
LADR2
10 to 180 sec.
LADR4
0.1 to 3 sec. (2)
LADR03
0.1 to 30 sec.
LADR23
10 to 180 sec.
LADR43
(Lockout Cover, see page 7 of Catalog 8501CT0101.)
(2) With extended scale from 0.1 to 0.6 s.
(3) With switching time of 40 ms ± 15 ms between opening of the N.C. contact and closing of the N.O. contact.
(4) Includes 1 N.O. & 1 N.C. overlapping contact.
For additional options and information, reference catalog 8501CT0101.
For other versions, please consult with your local Schneider Electric agency/
Square D sales office: visit www.us.telemanique.com.
5/29
NEMA Type
Contactors and starters
3-pole contactors and starters,
open style
(1) Standard control circuit voltages:
Volts
24
110
50 Hz
–
V02
60 Hz
V01 (4) –
Volts
240
380
50 Hz
–
V05
60 Hz
V03
–
120
208
220
–
–
V03
V02
V08
–
440
480
600
V06
–
–
–
V06
V07
For 24 V and 120 V coils add the letter “S” for separate control. Example: 8502SAO12 V01S .
Type
Contactors
3-pole, open style
Starters
3-pole, open style
Characteristics
NEMA Standard power ratings
size
Maximum Basic catalog number complete with code
of 3-phase motors 50/60 Hz
continuous indicating control circuit voltage (1)
Basic catalog number complete with code
indicating control circuit voltage (1)
current and optional Forms (2)
optional Forms (2) and “H” code (3)
Motor voltage
5
200 V
230 V
460 V
575 V
Hp kW
Hp kW
Hp kW
Hp kW
00
1.5 1.1
1.5 1.1
2
1.5
2
1.5
0
3
3
5
3.7
5
3.7
18 8502SBO2 ppp
8536 SBO2 ppp
8536 SCO3 ppp
8536 SDO1 ppp
2.2
2.2
A
9 8502SAO12 ppp
8536SAO12 ppp
1
7.5 5.5
7.5 5.5
10 7.5
10 7.5
27 8502SCO2 ppp
2
10 7.5
15 11
25 18.5
25 18.5
45 8502SDO2 ppp
3
25 18,5
30 22
50 37
50 37
90 8502SEO2 ppp
8536 SEO1 ppp
4
40 30
50 37
100 75
100 75
135 8502SFO2 ppp
8536 SFO1 ppp
8536 SGO1 ppp
5
75 55
100 75
200 150
200 150
270 8502SGO2 ppp
6
150 110
200 150
400 300
400 300
540 8502SHO2 ppp
8536 SHO2 ppp
7
–
300 220
600 450
600 450
810 8502SJO2 ppp
8536 SJO2 ppp
–
(2) For optional For ms, please consult your nearest Square D/Schneider Electric sales office.
(3) Add the letter “H” for Solid State Overload Relays, see tables below.
(4) 24 V coil is not a vailable for siz es 4 to 7. Available for sizes 00–3, specify the letter “S” for separate control.
Solid State Overload Relays
(6) Standard current ranges dependent on starter siz e:
Size
00
Current
ranges A
0
1
2
3
1.5–4.5 (8) 6–18
9–27
15–45
30–90
Size
4
5
6
7
Current
ranges A
45–135
90–270
180–540 (8)
270–810 (9)
Motor Logic® solid state relays
Without additional auxiliary contact
Form adders
Description
Motor Logic® solid state relays
With additional auxiliar y contact
Current
For use
Suffix to be added
Suffix to be added to
rang e
with
to the starter catalog number (7)
the starter catalog number (7)
Base unit,
(6)
8536 Sp
pp
H10 H11
H20
H21
H30
H31
Trip class 10
8736 Sp
pp
Base unit,
Trip class 20
(6)
Feature unit
(6)
8536 Sp
pp
pp
8736 Sp
8536 Sp
pp
8736 Sp
pp
(7) Example: 8536SAO12V01H10.
(8) Only availab le with feature units.
(9) Only availab le with feature units with auxiliary contact.
For additional infor mation, reference catalog 8502CT9701.
For other versions, please consult with your localSchneider Electric/
5/30
Square D sales office: visit www.us.telemanique.com.
NEMA Type
3-pole reversing contactors and
reversing starters, open style
(1) Standard control circuit voltages:
Volts
24
110
50 Hz
–
V02
60 Hz
V01 (4) –
Volts
240
380
50 Hz
–
V05
60 Hz
V03
–
120
208
220
–
–
V03
V02
V08
–
440
480
600
V06
–
–
–
V06
V07
For 24 V and 120 V coils add the letter “S” for separate control. Example: 8702SAO4 V01S .
Type
Rever sing contactors
3-pole, open style
Re versing starters
3-pole , open style
Characteristics
NEMA Standard power ratings
size
Maximum Basic catalog number complete with code
of 3-phase motors 50/60 Hz
continuous indicating control circuit voltage (1)
current and optional Forms (2)
Basic catalog n umber complete with code
indicating control circuit voltage (1)
optional Forms (2) and “H” code (3)
Motor voltage
200 V
230 V
460 V
575 V
Hp kW
Hp kW
Hp kW
Hp kW
A Ver tical
Side by side
Vertical
Side by side
00
1.5 1.1
1.5 1.1
2
1.5
2
1.5
9 –
8702SAO4 ppp
–
8736SAO16 ppp
0
3
3
5
3.7
5
3.7
18 8702SBO12 ppp
8702SBO4 ppp
8736SBO10 ppp
8736SBO4 ppp
1
7.5 5.5
7.5 5.5
10 7.5
10 7.5
27 8702SCO7 ppp
8702SCO8 ppp
8736SCO7 ppp
8736SCO8 ppp
2
10 7.5
15 11
25 18.5
25 18.5
45 8702SDO1 ppp
8702SDO2 ppp
8736SDO1 ppp
8736SDO2 ppp
3
25 18.5
30 22
50 37
50 37
90 8702SEO1 ppp
8702SEO2 ppp
8736SEO1 ppp
8736SEO2 ppp
4
40 30
50 37
100 75
100 75
135 8702SFO1 ppp
8702SFO3 ppp
8736SFO1 ppp
8736SFO3 ppp
5
75 55
100 75
200 150
200 150
270 8702SGO1 ppp
8702SGO3 ppp
8736SGO1 ppp
8736SGO3 ppp
6
150 110
200 150
400 300
400 300
540 –
8702SHO1 ppp
–
8736SHO1 ppp
7
–
300 220
600 450
600 450
810 –
8702SJO1 ppp
–
8736SJO1 ppp
2.2
–
2.2
5
(2) For optional Forms, please consult your nearest Square D/Schneider Electric sales office.
(3) Add the letter “H” for Solid State Overload Relays, see tables below.
(4) 24 V coil is not available for sizes 4 to 7. Available f or sizes 00–3, specify the letter “S” for separate control.
Solid State Overload Relays
Form adders
Motor Logic® PLUS solid state relays
200 to 480 V
Motor Logic® PLUS solid state relays
600 V
Suffix to be added
Suffix to be ad ded
Current range
to the starter catalog number (7)
to the starter catalog number (7)
0.5–2.3 A
B20
B24
2–9 A
B30
B34
6–27 A
B40
B44
10–45 A
B50
B54
20–90 A
B60
B64
60–135 A
B70
B74
120–270 A
B80
B84
240–540 A
B90
B94
(7) Example: 8536SAO12V01B20.
For additional information, reference catalog 8502CT9701.
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/31
NEMA Type
Combination starters
3-pole disconnect switch starters
NEMA 1 general purpose enclosure
Type
NEMA 12 dust-tight and drip-tight
industrial use enclosure
3-pole starters
3-pole starters,
3-pole starters,
3-pole starters,
non-reversing
non-reversing
non-reversing
non-reversing
with Class H fuses with Class R fuses with Class H fuses with Class R
fuses
Characteristics
Size
Standard power ratings
Fuse Basic catalog number
NEMA of 3-phase motors 50/60 Hz
Basic catalog number
Basic catalog number
Basic catalog number
size complete with code
complete with code
complete with code
complete with code
indicating control
indicating control
indicating
indicating
circuit voltage (1)
circuit voltage (1)
circuit voltage (1)
circuit voltage (1)
optional Forms (2)
and optional Forms (2)
optional Forms (2)
and optional Forms (2)
Motor voltage (star ter voltage)
and H code (3)
and H code (3)
200 V (208 V) 230 V (240 V) 460 V (480 V) 575 V (600 V)
0
5
1
2
3
4
5
Hp kW
Hp kW
Hp kW
Hp kW
3
2.2
3
2.2
–
–
–
–
30 8538SBG12 ppp
8538SBG32 ppp
8538SBA (4) 2 ppp
8538SBA (5) 2 ppp
–
–
–
–
5
3.75
5
3.75
30 8538SBG13 ppp
8538SBG33 ppp
8538SBA (4) 3 ppp
8538SBA (5) 3 ppp
5
3.75
5
3.75
–
–
–
–
30 8538SCG12 ppp
8538SCG32 ppp
8538SCA (4) 2 ppp
8538SCA (5) 2 ppp
–
–
–
–
10 7.5
10 7.5
30 8538SCG14 ppp
8538SCG34 ppp
8538SCA (4) 4 ppp
8538SCA (5) 4 ppp
7.5 5.5
7.5 5.5
–
–
–
–
60 8538SCG13 ppp
8538SCG33 ppp
8538SCA (4) 3 ppp
8538SCA (5) 3 ppp
10 7.5
15 11
–
–
–
–
60 8538SDG12 ppp
8538SDG32 ppp
8538SDA (4) 2 ppp
8538SDA (5) 2 ppp
–
–
–
–
15 11
15 11
30 8538SDG16 ppp
8538SDG36 ppp
8538SDA (4) 6 ppp
8538SDA (5) 6 ppp
–
–
–
–
25 18.5
25 18.5
60 8538SDG14 ppp
8538SDG34 ppp
8538SDA (4) 4 ppp
8538SDA (5) 4 ppp
–
100 8538SEG15 ppp
8538SEG35 ppp
8538SEA (4) 5 ppp
8538SEA (5) 5 ppp
20 15
25 18.5
–
–
–
50 37
50 37
100 8538SEG13 ppp
8538SEG33 ppp
8538SEA (4) 3 ppp
8538SEA (5) 3 ppp
–
–
–
–
25 18,5
30 22
–
–
–
–
200 8538SEG12 ppp
8538SEG32 ppp
8538SEA (4) 2 ppp
8538SEA (5) 2 ppp
40 30
50 37
–
–
–
–
200 8538SFG15 ppp
8538SFG35 ppp
8538SFA (4) 5 ppp
8538SFA (5) 5 ppp
–
–
100 75
100 75
200 8538SFG13 ppp
8538SFG33 ppp
8538SFA (4) 3 ppp
8538SFA (5) 3 ppp
–
–
400 8538SGG15 ppp
8538SGG35 ppp
8538SGA (4) 5 ppp
8538SGA (5) 5 ppp
8538SGG33 ppp
8538SGA (4) 3 ppp
8538SGA (5) 3 ppp
–
75 55
–
100 75
–
–
200 150
200 150
400 8538SGG13 ppp
150 110
200 150
–
–
600 8538SHG13 ppp
8538SHG33 ppp
8538SHA (4) 3 ppp
8538SHA (5) 3 ppp
–
–
400 300
600 8538SHG12 ppp
8538SHG32 ppp
8538SHA (4) 2 ppp
8538SHA (5) 2 ppp
–
6
A
–
–
–
–
–
–
–
400 300
(1) Standard control circuit voltages:
Volts
24
110
120
208
220
240
380
440
480
600
50 Hz
–
V02
–
–
V03
–
V05
V06
–
–
60 Hz
V01 (6)(7) –
V02 (6)
V08
–
V03
–
–
V06
V07
For 24 V and 120 V coils add the letter “S” for separate control. Example: 8538SBG12 V01S .
(2) For optional For ms, please consult your nearest Square D/Schneider Electric sales office.
(3) Add the letter “H” for Solid State Overload Relays, see table on page opposite.
(4) To order a unit with external reset, replace (4) with “2”. To order a unit without exter nal reset, replace (4) with “1”.
(5) To order a unit with external reset, replace (5) with “4”. To order a unit without exter nal reset, replace (5) with “3”.
(6) To order this voltage code, add the letter “S” (separ ate contol).
(7) 24 V coil not a vailable for siz es 4 to 6. Availab le for sizes 0 to 3, specify letter “S” (separate contol).
For additional infor mation, reference catalog 8538CT9701.
For other versions, please consult with your localSchneider Electric/
5/32
Square D sales office: visit www.us.telemanique.com.
NEMA Type
Solid state overload Relays
Motor Logic®
solid state relays
Form adders
For use
Current
with
rang e
Description
Suffix to be added
p /Sp
p A 1p
p /S pA 2p
8538S pG 1p
p
(8)
Base unit, Trip Class 10
H10
(except 8538 SDG16/SDA16/SDA26)
(8)
Base unit, Trip Class 20
H20
to the starter catalog number(9)
(8)
Feature unit
H30
8538SBG12/13,
3–9 A
Base unit, Trip Class 10
H109
8538SBA12/22/13/23,
3–9 A
Base unit, Trip Class 20
H209
8538SCG12/14,
1.5–4.5 A
Feature unit
H308
8538SCA12/22/14/24,
3–9 A
Feature unit
H309
8538SCG12/14
6–18 A
Base unit, Trip Class 10
H100
8538SCA12/22/14/24,
6–18 A
Base unit, Trip Class 20
H200
8538SDG16
6–18 A
Feature unit
H300
8538SDG16,
9–27 A
Base unit, Trip Class 10
H101
8538SDA16/26
9–27 A
Base unit, Trip Class 20
H201
9–27 A
Feature unit
H301
8538SDG16,
8538SDA16/26
5
8538SDA16/26
(8) Standard current ranges dependent on star ter size:
Size
00
0
1
2
3
4
5
6
7
Current
r anges A
3–9
6–18
9–27
15–45
30–90
45–135
90–270
180–540 (10)
270–810 (11)
(9) Example: 8538SBG12V01H10 .
(10) Only available with feature units.
(11) Only available with feature units with auxiliar y contact.
For additional information, reference catalog 9065CT9701.
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/33
NEMA Type
Combination starters
Mag-Gard®
circuit-breaker starters
(1) Standard control circuit voltages:
Volts
24
110
120
208
220
50 Hz
–
V02
–
–
V03
60 Hz
V01 (4)(5) –
V02 (4)
V08
–
Volts
240
380
440
480
600
50 Hz
–
V05
V06
–
–
60 Hz
V03
–
–
V06
V07
NEMA 1 general purpose enclosure
For 24 V and 120 V coils add the letter “ S” for separate control.Example: 8539SCG41V02H10S.
Type
3-pole circuit breaker starter s,
non-reversing
Characteristics
NEMA Standard power ratings
size
Circuit-breaker
of 3-phase motors 50/60 Hz
Basic catalog number complete with code indicating
control circuit voltage (1), optional Forms (2)
and “H” code (3)
Motor voltage (star ter voltage)
200 V (208 V) 230 V (240 V) 460 V (480 V) 575 V (600 V)
0
1
5
2
3
4
5
6
7
Hp kW
Hp kW
Hp kW
Hp kW
0.3 0.2
0.3 0.2
1
0.75
1
0.75
GJL 36003 MO1
8539SBG41 ppp
1
0.75
1
0.75
3
2.2
3
2.2
GJL 36007 MO2
8539SBG42 ppp
3
2.2
3
2.2
5
3.7
5
3.7
GJL 36015 MO3
8539SBG43 ppp
0.3 0.2
0.3 0.2
1
0.75
1
0.75
GJL 36003 MO1
8539SCG41 ppp
1
0.75
1
0.75
3
2.2
3
2.2
GJL 36007 MO2
8539SCG42 ppp
3
2.2
3
2.2
7.5 5.5
10 7.5
GJL 36015 MO3
8539SCG43 ppp
5
3.7
7.5 5.5
10 7.5
–
–
GJL 36030 MO4
8539SCG44 ppp
7.5 5.5
–
–
–
–
–
GJL 36050 MO5
8539SCG45 ppp
3
2.2
3
2.2
7.5 5.5
10 7.5
GJL 36015 MO3
8539SDG41 ppp
5
3.7
7.5 5.5
15 11
20 15
GJL 36030 MO4
8539SDG42 ppp
10 7.5
10 7.5
25 18.5
25 18.5
GJL 36050 MO5
8539SDG43 ppp
–
–
15 11
–
–
GJL 36075 MO6
8539SDG44 ppp
–
–
–
25 18.5
30 22
GJL 36050 MO5
8539SEG41 ppp
–
–
–
–
25 18.5
30 22
30 22
50 37
FAL 36100 18M
8539SEG42 ppp
30 22
–
75 55
100 75
KAL 36250 25M
8539SFG42 ppp
–
–
40 30
–
–
–
KAL 36250 26M
8539SFG43 ppp
–
–
50 37
100 75
–
–
KAL 36250 29M
8539SFG44 ppp
–
–
–
–
–
–
125 90
KAL 36250 29M
8539SGG41 ppp
50 37
–
–
–
–
150 110
KAL 36250 30M
8539SGG42 ppp
–
60 45
125 90
–
KAL 36250 31M
8539SGG43 ppp
60 45
75 55
150 110
200 150
LAL 36400 32M
8539SGG44 ppp
75 55
–
–
–
–
LAL 36400 33M
8539SGG45 ppp
–
–
100 75
200 150
–
–
LAL 36400 35M
8539SGG46 ppp
–
–
–
–
–
250 185
LAL 36400 35M
8539SHG42 ppp
100 75
–
–
250 185
300 220
LAL 36400 36M
8539SHG43 ppp
125 90
150 110
300 220
400 300
MAL 36600 40M
8539SHG44 ppp
150 110
–
350 250
–
–
MAL 36600 42M
8539SHG45 ppp
–
–
200 150
400 300
–
–
MAL 36600 44M
8539SHG46 ppp
–
–
–
–
500 370
MAL 36800 44M
8539SJG41 ppp
–
–
250 185
500 370
600 450
MAL 36800 45M
8539SJG42 ppp
–
–
300 220
600 450
–
MAL 361000 47M
8539SJG43 ppp
–
–
–
–
–
–
–
–
–
–
–
(2) For optional For ms, please consult your nearest Schneider Electric/Square D sales office.
(3) Add the letter “H” for Motor Logic® solid state overload relays, see page 1-30.
Motor Logic® PLUS solid state overload relays are not available on combination star ters.
(4) For this voltage code, add the letter “S” (separate contol).
(5) 24 V coil not a vailable for siz es 4 to 6. Availab le for sizes 0 to 3, specify letter “S” (separate contol).
For additional information, reference catalog 8538CT9701.
For other versions, please consult with your localSchneider Electric/
5/34
Square D sales office: visit www.us.telemanique.com.
NEMA Type
Thermal-magnetic
circuit-breaker starters
(1) Standard control circuit voltages:
Volts
24
110
50 Hz
–
V02
60 Hz
V01 (4)(5) –
Volts
240
380
50 Hz
–
V05
60 Hz
V03
–
120
208
220
–
–
V03
V02 (4)
V08
–
440
480
600
V06
–
–
–
V06
V07
NEMA 1 general purpose enclosure
For 24 V and 120 V coils add the letter “S” for separate control. Example: 8539SBG1V02H10S.
Type
3-pole thermal-magnetic circuit-breaker starter s,
non-reversing
Characteristics
NEMA Standard power ratings
size
Circuit-breaker
Basic catalog n umber complete with code indicating
of 3-phase motors 50/60 Hz
control circuit voltage (1), optional Forms (2)
and “H “code (3)
Motor voltage (starter voltage)
0
1
2
3
4
5
6
7
200 V (208 V) 230 V (240 V)
460 V (480 V) 575 V (600 V)
Hp kW
Hp kW
Hp kW
Hp kW
Type
Current rating
2
1.5
2
1.5
–
–
–
–
–
–
–
–
5
3.7
5
3.7
FAL
15 8539SBG2 ppp
3
2.2
3
2.2
–
–
–
–
FAL
20 8539SBG3 ppp
5
A
15 8539SBG1 ppp
FAL
3.7
–
–
–
–
–
–
FAL
35 8539SCG5 ppp
7.5 5.5
–
–
–
–
–
–
FAL
50 8539SCG2 ppp
–
–
5
3.7
–
–
–
–
FAL
30 8539SCG1 ppp
–
–
7.5 5.5
–
–
–
–
FAL
45 8539SCG6 ppp
–
–
–
–
7.5 5.5
10 7.5
FAL
20 8539SCG3 ppp
–
–
–
–
10 7.5
–
FAL
25 8539SCG7 ppp
–
–
–
–
–
–
7.5 5.5
FAL
15 8539SCG8 ppp
–
10 7.5
10 7.5
–
–
–
–
FAL
60 8539SDG1 ppp
–
–
15 11
–
–
–
–
FAL
80 8539SDG7 ppp
–
–
–
–
7.5 5.5
–
–
FAL
20 8539SDG3 ppp
–
–
–
–
20 15
25 18,5
FAL
60 8539SDG4 ppp
–
–
–
–
25 18,5
–
FAL
70 8539SDG5 ppp
–
–
–
–
–
–
15 11
FAL
35 8539SDG8 ppp
–
–
–
–
–
–
20 15
FAL
45 8539SDG9 ppp
–
15 11
20 15
40 30
50 37
FAL
90 8539SEG3 ppp
20 15
25 18.5
50 37
–
–
FAL
100 8539SEG1 ppp
25 18.5
30 22
–
–
–
KAL
110 8539SEG5 ppp
–
–
–
–
30 22
40 30
FAL
80 8539SEG6 ppp
–
–
–
–
–
30 22
FAL
60 8539SEG4 ppp
30 22
–
–
75 55
–
–
KAL
125 8539SFG3 ppp
40 30
50 37
100 75
–
–
KAL
200 8539SFG4 ppp
–
–
40 30
–
100 75
KAL
150 8539SFG1 ppp
–
–
–
–
60 45
75 55
KAL
110 8539SFG5 ppp
–
–
–
–
–
–
60 45
FAL
100 8539SFG6 ppp
50 37
–
–
–
–
150 110
LAL
200 8539SGG6 ppp
60 45
75 55
150 110
200 150
LAL
250 8539SGG1 ppp
75 55
–
–
–
–
LAL
300 8539SGG4 ppp
–
–
60 45
125 90
–
–
LAL
225 8539SGG3 ppp
–
–
100 75
200 150
–
–
LAL
350 8539SGG2 ppp
–
–
–
–
125 90
KAL
200 8539SGG7 ppp
450 8539SHG4 ppp
–
–
–
–
–
–
–
100 75
125 90
250 185
300 220
MAL
125 90
150 110
300 220
400 300
MAL
600 8539SHG3 ppp
150 110
–
350 250
–
–
MAL
600 8539SHG5 ppp
–
–
200 150
400 300
–
–
MAL
800 8539SHG7 ppp
–
–
–
–
–
–
250 185
MAL
250 8539SHG6 ppp
–
–
–
–
–
–
350 250
MAL
500 8539SHG2 ppp
–
–
250 185
500 370
600 450
MAL
–
–
300 220
600 450
–
MAL
–
–
–
–
500 370
–
–
–
–
5
900 8539SJG2 ppp
1000
MAL
8539SJG3 ppp
800 8539SJG1 ppp
(2) For optional Forms, please consult your nearest Schneider Electric/Square D sales office.
(3) Add the letter “H” for Motor Logic® solid state over load relays, see page 5/30.
Motor Logic® PLUS solid state overload rela ys are not available on combination star ters.
(4) For this voltage code, add the letter “ S” (separ ate contol).
(5) 24 V coil not availab le for sizes 4 to 6. Available for sizes 0 to 3, specify letter “ S” (separate contol).
For additional information, reference catalog 8538CT9701.
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/35
NEMA Type
Solid State Overload Relays
Motor Logic®
Base units
Type
5
NEMA Size
Full load
3-phase
current range
00C (1)
3–9 A
0 (1)
6–18 A
1 (1)
9–27 A
2
15–45 A
3
30–90 A
4
45–135 A
Base units
for separate mounting
Base units for retr ofit
to Type S starters (2)
Type
Catalog number
Catalog number
Trip Class 10
9065SSC10
9065SSC10
Trip Class 20
9065SSC20
9065SSC20
Trip Class 10
9065SS010
9065SS010
Trip Class 20
9065SS020
9065SS020
Trip Class 10
9065SS110
9065SS110
Trip Class 20
9065SS120
9065SS120
Trip Class 10
9065SS210
9065SR210
Trip Cass 20
9065SS220
9065SR220
Trip Class 10
9065SS310
9065SR310
Trip Class 20
9065SS320
9065SR320
Trip Class 10
9065SS410
9065SR410
Trip Cass 20
9065SS420
9065SR420
Motor Logic
feature units
Type
NEMA Size
Full load
3-phase
current range
Feature units
for separate mounting
Feature units
for retr ofit to Type S starters (2)
Type
Catalog number
Catalog no.
9065SFB20
00B (1)
1.5–4.5 A
Trip Class 10/20
9065SFB20
00C (1)
3–9 A
Trip Class 10/20
9065SFC20
9065SFC20
0 (1)
6–18 A
Trip Class 10/20
9065SF020
9065SF020
1 (1)
9–27 A
Trip Class 10/20
9065SF120
9065SF120
2
15–45 A
Trip Class 10/20
9065SF220
9065ST220
3
30–90 A
Trip Class 10/20
9065SF320
9065ST320
4
45–135 A
Trip Class 10/20
9065SF420
9065ST420
5 (3)
90–270 A
Trip Class 10/20
–
9065ST520
6(3)
180–540 A
Trip Class 10/20
–
9065ST620
7 (3)
270–810 A
Trip Class 10/20
–
9065ST720
(1) For power connection kit, see table on page opposite.
(2) For Type S star ter catalog numbers, see page 5/30.
(3) Replacement for existing Type S star ters with an existing Motor Logic® solid state overload relay. Does not include primary current transformer or additional components.
For additional infor mation, reference catalog 9065CT9701.
For other versions, please consult with your localSchneider Electric/
5/36
Square D sales office: visit www.us.telemanique.com.
NEMA Type
Motor Logic PLUS
programmable units
Type
Base units for separate mounting
NEMA Size
Current
3-phase
rang e
0
Voltage
A
V
0.5–2.3
200–480
Catalog number
9065SPB4
600
9065SPB6
0
2–9
200–480
9065SPC4
600
9065SPC6
1
6–27
200–480
9065SP14
600
9065SP16
200–480
9065SP24
600
9065SP26
200–480
9065SP34
600
9065SP36
200–480
9065SP44
600
9065SP46
200–480
9065SP54
600
9065SP56
200–480
9065SP64
600
9065SP66
2
3
4 (1)
5 (2)
6 (3)
10–45
20–90
60–135
120–270
240–540
5
(1) Size 4 requires the use of an external current transfor mer. Ratio of 150:5 recommended.
(2) Size 5 requires the use of an external current transfor mer. Ratio of 300:5 recommended.
(3) Size 6 requires the use of an external current transfor mer. Ratio of 600:5 recommended.
Accessories
Type
Power connection kits
Type
Description
For use on
Catalog number
Lug connector
For separate mounting
9065 Sp (Sizes 00B/00C/0/1)
9999LLO
kits
For mounting on
9065 Sp (Sizes 00B/00C/0/1)
9999LBO
Type S star ters
For additional information, reference catalog 9065CT9701.
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/37
NEMA Type
Definite purpose contactors
Compact contactors,
single-pole and 2-pole
Type
Compact contactors
single-pole
Full
Locked rotor
Resistive Motor power
load
current
load
115 V
current
277 V 480 V 575 V
current
single-phase single-phase 3-phase
A
A
A
A
N.O. poles
230 V
230 V460/575 V
3-phase
A
Hp
kW
Hp
kW
Hp
kW
Hp
kW
Compact contactors
2-pole (3)
Basic catalog number
Basic catalog number
complete with code
complete with code
indicating control
indicating control
circuit voltage (1)
circuit voltage (1)
20
100
100
80
25
1
0.75
2
1.5
–
–
–
–
1 or 2
8910DP11 ppp
8910DP12 ppp
25
125
125
100
30
2
1.5
3
2.2
–
–
–
–
1 or 2
8910DP21 ppp
8910DP22 ppp
30
150
150
120
40
2
1.5
(1)
(1)
–
–
–
–
1 or 2
8910DP31 ppp
8910DP32 ppp
40
240
200
160
50 (2)
2
1.5
5
3.7
–
–
–
–
1 or 2
8910DP41 ppp
8910DP42 ppp
(1) 3 hp (2.2 kW) for 1-pole device; 5 hp (3.7 kW) for 2-pole device.
5
2, 3 and 4-pole,
contactors
Type
2, 3 and 4-pole,
contactors (3)
Full
Locked rotor
Resistive Motor power
load
current
load
115 V
current
277 V 480 V 575 V
current
single-phase single-phase 3-phase
3-phase
A
A
A
A
A
Hp
kW
Hp
kW
Hp
kW
Hp
20
120
100
80
25
1
1.1
2
1.5
5
3.7
7.5 5.5
25
30
40
50
60
75
90
120
150
180
240
300
360
450
540
720
125
150
200
250
300
375
450
600
100
120
160
200
240
300
360
480
35
40
50
62
75
94
120
120
2
2
3
3
5
5
7.5
10
N.O. poles
230 V
1.5
1.5
2.2
2.2
3.7
3.7
5.5
7.5
3
5
7.5
10
10
15
20
25
230 V460/575 V
2.2
3.7
5.5
7.5
7.5
11
15
18.5
7.5 5.5 10
10
10
15
25
25
30
40
7.5
7.5
11
15
20
30
18.5 30
18.5 40
22
30
50
75
Basic catalog number
complete with code indicating
control circuit voltage (1)
kW
7.5
11
15
22
22
30
37
55
2
8910DPA12 ppp
3
8910DPA13 ppp
4
8910DPA14 ppp
2
8910DPA22 ppp
3
8910DPA23 ppp
4
8910DPA24 ppp
2
8910DPA32 ppp
3
8910DPA33 ppp
4
8910DPA34 ppp
2
8910DPA42 ppp
3
8910DPA43 ppp
4
8910DPA44 ppp
2
8910DPA52 ppp
3
8910DPA53 ppp
2
8910DPA62 ppp
3
8910DPA63 ppp
2
8910DPA72 ppp
3
8910DPA73 ppp
2
8910DPA92 ppp
3
8910DPA93 ppp
2
8910DPA122 ppp
3
8910DPA123 ppp
For additional infor mation, reference catalog 8910CT9301R6/97.
For other versions, please consult with your localSchneider Electric/
5/38
Square D sales office: visit www.us.telemanique.com.
NEMA Type
4-pole contactors
Type
4-pole contactors
with 2 N.O. and 2 N.C. poles
Full
Locked rotor
Resistive Motor power
load
current
load
115 V
230 V
230 V460/575 V
N.O.
N.C.
Basic catalog number
poles
poles
complete with code indicating
(3)
(7)
control circuit voltage (1)
current
277 V 480 V 575 V
current
single-phase single-phase 3-phase
3-phase
A
A
A
A
A
Hp
kW
Hp
kW
Hp
kW
Hp
20
120
100
80
25
1
0.75
2
1.5
5
3.7
7.5 5.5
2
2
8910DPA14 ppp Y392
25
150
125
100
35
2
1.5
3
2.2
7.5 5.5 10
7.5
2
2
8910DPA24 ppp Y392
30
180
150
120
40
2
1.5
5
3.7
10
7.5
15
11
2
2
8910DPA34 ppp Y392
40
240
200
160
50
3
2.2
7.5
5.5
10
7.5
20
15
2
2
8910DPA44 ppp Y392
kW
5
Accessories
Type
External auxiliar y contacts
For use on
Description
Catalog number
8910DPA
1 N.O. contact
9999D10
1 N.C. contact
9999D01
1 N.O. and 1 N.C. contacts
9999D11
8910DPA122/123
2 N.O. contacts
9999D20
1 N.O. contact
9999SX6
1 N.C. contact
9999SX7
1 N.O. and 1 N.C. isolated contacts
9999SX8
1 N.O. overlapping contact
9999SX9
1 N.C. over lapping contact
9999SX10
(1) Standard control circuit voltages for 8910DP/DPA :
Volts
24
110
120
208-240 220
277
440
480
550
50 Hz
V14
V02
–
–
V09
–
V06 (4)
–
V07 (5)
600
–
60 Hz
V14
–
V02
V09
–
V04
–
V06 (4)
–
V07 (5)
600
Standard control circuit voltage for 8910DPA122/DPA123:
Volts
24
110
120
208
220
230-240 440
480
550
50 Hz
V12
V02
–
–
V03
–
V06
–
V07
–
60 Hz
V01 (6)
–
V02
V08
–
V03
–
V06
–
V07
(2) 50 A resistive limited to 277 V (single pole device only). All other contactors r ated 40 A resistive (above 277 V).
(3) Above 240 V, all lines must be switched.
(4) Not available for type 8910DP11 to 8910DP31 single-pole devices .
(5) Not availab le for type 8910DP single and 2-pole devices .
(6) Only availab le on types 8910DPA122/DPA123.
(7) N.C. poles on outside. N.C. poles “open” before N.O. poles “close”.
For additional information, reference catalog 8910CT9301R6/97.
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/39
NEMA Type
Lighting contactors
Multipole contactors
Types L and LX
Type
Thermal operating
Number of poles (3)
current (A)
20
Multipole contactors, open style,
electrically held (2)
Multipole contactors, open style,
mechanically held (2)
Basic catalog number complete with code
Basic catalog number complete with code
indicating control circuit voltage (1)
indicating control circuit voltage (1)
2
8903LO20 ppp
8903LXO20 ppp
3
8903LO30 ppp
8903LXO30 ppp
4
8903LO40 ppp
8903LXO40 ppp
6
8903LO60 ppp
8903LXO60 ppp
8
8903LO 80 ppp
8903LXO80 ppp
10
8903LO1000 ppp
8903LXO1000 ppp
12
8903LO1200 ppp
8903LXO1200 ppp
Multipole contactors Type S
5
(1) Standard control circuit voltages:
Volts
24 (4) 110
120
208
220
50 Hz
–
V02
–
–
V03
60 Hz
V01
–
V02
V08
–
Volts
240
277
440
480
50 Hz
–
–
V06
–
60 Hz
V03
V04
–
V06
For Forms and kits, please consult your nearest Square D/Schneider Electr ic sales office.
Type
Thermal operating
Number of poles
current (A)
30
60
100
200
300
400 (5)
600 (5)
800 (5)
Multipole contactors, open style,
electrically held (2)
Multipole contactors, open style,
mechanically held (2)
Basic catalog number complete with code
Basic catalog number complete with code
indicating control circuit voltage (1)
indicating control circuit voltage (1)
2
8903SMO1 ppp
8903SMO10 ppp
3
8903SMO2 ppp
8903SMO11 ppp
4
8903SMO3 ppp
8903SMO12 ppp
5
8903SMO4 ppp
8903SMO13 ppp
2
8903SPO1 ppp
8903SPO10 ppp
3
8903SPO2 ppp
8903SPO11 ppp
4
8903SPO3 ppp
8903SPO12 ppp
5
8903SPO4 ppp
8903SPO13 ppp
2
8903SQO1 ppp
8903SQO10 ppp
3
8903SQO2 ppp
8903SQO11 ppp
4
8903SQO3 ppp
8903SQO12 ppp
5
8903SQO4 ppp
8903SQO13 ppp
2
8903SVO1 ppp
8903SVO10 ppp
3
8903SVO2 ppp
8903SVO11 ppp
4
8903SVO3 ppp
8903SVO12 ppp
5
8903SVO4 ppp
–
2
8903SXO1 ppp
8903SXO13 ppp
3
8903SXO2 ppp
8903SXO14 ppp
2
8903SYO1 ppp
8903SYO16 ppp
3
8903SYO2 ppp
8903SYO17 ppp
2
8903SZO1 ppp
8903SZO18 ppp
3
8903SZO2 ppp
8903SZO19 ppp
2
8903SJO1 ppp
8903SJO10 ppp
3
8903SJO2 ppp
8903SJO11 ppp
(2) All lighting contactors are provided with separate control as standard, except electrically held 400, 600 and 800 A devices .
Electrically held 400, 600 and 800 A devices are provided with common control.
(3) For factory conversion of N.O. contacts to N.C., order following this example: for 2 N.O. + 2 N.C., order catalog no. 8903LO22.
There is a maximum of eight N.C. poles for Type 8903L contactors and a maximum of six N.C. poles for Type 8903LX contactors (field con version only).
Versions are availab le with up to 12 N.C. poles (factory only).
(4) 24 V coils are not availab le for 200–800 A devices.
(5) Form F4T is provided as standard on electrically held devices 400–800 A; include line voltage when ordering. Control voltage is 120–60.
For 400–800 A devices—must specify line voltage, not control voltage.
For additional information, reference catalog 8903CT9701.
For other versions, please consult with your localSchneider Electric/
5/40
Square D sales office: visit www.us.telemanique.com.
Manual starters and switches NEMA Type
Manual starters Type F, general purpose surface
mounting enclosure (NEMA 1)
Type
Single units,
standard starters
Single units,
starters with handle
padlockable in the ‘O’ position
Catalog number
Catalog number
Standard
2510FG1
2510FG5
With red pilot light
2510FG1P
2510FG5P
Standard
2510FG2
2510FG6
With red pilot light
2510FG2P
2510FG6P
Standard
2510FG3
–
With red pilot light
2510FG3P
–
Standard
2510FG4
–
With red pilot light
2510FG4P
–
Duplex units,
1 starter
in duplex enclosure
Duplex units,
2 starters
in one enclosure
Catalog number
Catalog number
Type of
Number Maximum power
Maximum Features
operator
of poles of single-phase motors
continuous
Toggle
1
115-230 Vac 115-230 Vdc 277 Vac
current
Hp
kW
Hp
kW
Hp
kW
A
1
0.75
-
-
1
0.75
16
operator
2
1
0.75 0.75 0.55 1
Removable 1
1
0.75
(1)
-
-
1
0.75
16
0.75
16
key
(1)
2
1
0.75 0.75 0.55 1
0.75
16
Type
Type of
Number Maximum power
Maximum Features
operator
of poles of single-phase motors
continuous
Toggle
2 (3)
115-230 Vac 115-230 Vdc 277 Vac
current
Hp
kW
kW
A
1
0.75 0.75 0.55 1
0.75
16
Hp
kW
Hp
operator
Standard
2510FG02
2510FG22
With red pilot light
2510FG02P
2510FG22P
With red pilot light
2510FG04P
2510FG44P
5
(1) (2)
Removable 2 (3)
1
0.75 0.75 0.55 1
0.75
16
key
(1) (2)
Type
Duplex units,
star ters with “AUTO-OFF-HAND” selector switch
Type of
operator
Toggle
Number
Maximum power
Maximum Features
of poles of single-phase motors
1
115-230 Vac 115-230 Vdc 277 Vac
current
Hp
kW
Hp
kW
Hp
kW
A
1
0.75
-
-
1
0.75
16
operator
2
1
0.75 0.75 0.55 1
0.75
16
Removable 2
1
0.75 0.75 0.55 1
0.75
16
(1)
Catalog number
continuous
Standard
2510FG71
With red pilot light
2510FG71P
Standard
2510FG72
With red pilot light
2510FG72P
With red pilot light
2510FG74P
ke y (1)
(1) One ther mal unit is required
(2) For two star ters in one enclosure, two thermal units are required.
(3) Two poles for each star ter.
For additional information, reference catalog 2570CT9701.
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/41
NEMA Type
Manual starters and switches
Manual switches Type K, in general purpose
surface mounting enclosure (NEMA 1)
Type
Non-reversing
Type of
No. of
Maximum motor powers
operator
poles
115 Vac
230 Vac
460 Vac
575 Vac
90 Vdc
115 Vdc
230 Vdc
current
Hp kW
Hp kW
Hp kW
Hp kW
Hp kW
Hp kW
Hp kW
A
Toggle
2
2
1.5
2
1.5
3
2.2
3
2.2
1
0.75
2
1.5
1.5 1.1
30
Standard
2510KG1
2
1.5
2
1.5
3
2.2
3
2.2
1
0.75
2
1.5
1.5 1.1
30
(1) 115 Vac
2510KG1A
2
1.5
2
1.5
3
2.2
3
2.2
1
0.75
2
1.5
1.5 1.1
30
(1) 230 Vac
2510KG1B
2
1.5
7.5 5.6
10 7.5
10 7.5
1
0.75
2
1.5
1.5 1.1
30
Standard
2510KG2
2
1.5
7.5 5.6
10 7.5
10 7.5
1
0.75
2
1.5
1.5 1.1
30
(1) 208–277 Vac
2510KG2B
2
1.5
7.5 5.6
10 7.5
10 7.5
1
0.75
2
1.5
1.5 1.1
30
(1) 440–600 Vac
2510KG2C
2
1.5
3
2.2
7.5 5.6
10 7.5
1
0.75
2
1.5
1.5 1.1
30
Standard
2510KG5
2
1.5
3
2.2
7.5 5.6
10 7.5
1
0.75
2
1.5
1.5 1.1
30
(1) 115 Vac
2510KG5A
2
1.5
3
2.2
7.5 5.6
10 7.5
1
0.75
2
1.5
1.5 1.1
30
(1) 230 Vac
2510KG5B
2
1.5
7.5 5.6
15 11.2
20 14.9
1
0.75
2
1.5
1.5 1.1
30
Standard
2510KG6
2
1.5
7.5 5.6
15 11.2
20 14.9
1
0.75
2
1.5
1.5 1.1
30
(1) 208–277 Vac
2510KG6B
2
1.5
7.5 5.6
15 11.2
20 14.9
1
0.75
2
1.5
1.5 1.1
30
(1) 440–600 Vac
2510KG6C
2
1.5
2
1.5
3
2.2
3
2.2
1
0.75
2
1.5
1.5 1.1
30
Standard
2510KG3
2
1.5
2
1.5
3
2.2
3
2.2
1
0.75
2
1.5
1.5 1.1
30
(1) 115 Vac
2510KG3A
2
1.5
2
1.5
3
2.2
3
2.2
1
0.75
2
1.5
1.5 1.1
30
(1) 230 Vac
2510KG3B
2
1.5
7.5 5.6
10 7.5
10 7.5
1
0.75
2
1.5
1.5 1.1
30
Standard
2510KG4
2
1.5
7.5 5.6
10 7.5
10 7.5
1
0.75
2
1.5
1.5 1.1
30
(1) 208–277 Vac
2510KG4B
2
1.5
7.5 5.6
10 7.5
10 7.5
1
0.75
2
1.5
1.5 1.1
30
(1) 440–600 Vac
2510KG4C
operator
3
2
3
5
Removable
2
key
3
Max. continuous
Catalog number
Features
(1) With red pilot light.
For additional infor mation, reference catalog 2510CT9701.
For other versions, please consult with your localSchneider Electric/
5/42
Square D sales office: visit www.us.telemanique.com.
NEMA Type
Manual switches Types T and M, in general
purpose surface mounting enclosure (NEMA 1)
Type
Non-reversing
Type of
No. of
operator
poles
NEMA Size
Ratings
Catalog number
Motor voltage
Max. power
DC
Toggle operator
AC 2
M-0
M-1
M-1P
AC 3
M-0
M-1
DC 2
M-0
M-1
Push button
AC 2
M-0
M-1
M-1P
AC 3
M-0
M-1
DC 2
M-0
M-1
3-phase
Single-phase
V
Hp
kW
Hp
kW
Hp
kW
115
–
–
–
–
1
0.75
230
–
–
–
–
2
1.5
115
–
–
–
–
2
1.5
230
–
–
–
–
3
2.2
115
–
–
–
–
3
2.2
230
–
–
–
–
5
3.7
200–230
–
–
3 (2)
2.2 (2)
–
–
380–575
–
–
5 (3)
3.7 (3)
–
–
200–230
–
–
7.5 (2)
5.5 (2)
–
–
380–575
–
–
10 (3)
7.5 (3)
–
–
115
1
0.75
–
–
–
–
230
1.5
1.1
–
–
–
–
115
1.5
1.1
–
–
–
–
230
2
1.5
–
–
–
–
115
–
–
–
–
1
0.75
230
–
–
–
–
2
1.5
115
–
–
–
–
2
1.5
230
–
–
–
–
3
2.2
115
–
–
–
–
3
2.2
230
–
–
–
–
5
3.7
200–230
–
–
3 (2)
2.2 (2)
–
–
380–575
–
–
5 (3)
3.7 (3)
–
–
200–230
–
–
7.5 (2)
5.5 (2)
–
–
380–575
–
–
10 (3)
7.5 (3)
–
–
115
1
0.75
–
–
–
–
230
1.5
1.1
–
–
–
–
115
1.5
1.1
–
–
–
–
230
2
1.5
–
–
–
–
2510TBG1
2510TCG1
2510TCG2
2510TBG2
2510TCG3
5
2510TBG4
2510TCG5
2510MBG1
2510MCG1
2510MCG2
2510MBG2
2510MCG3
2510MBG4
2510MCG5
(2) Value for 230 V.
(3) Value for 575 V.
For additional information, reference catalog 2510CT9701.
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/43
NEMA Type
Accessories
Replacement parts kits
Type
Description
Replacement
parts kits
For use with
Number of poles
NEMA Siz e
Catalog number
in the kit
Class
Type
or current
Replacement parts kits
8502, 8536, 8538,
SA (Series B)
00
3
9998SJ1
(the kit contains the moving and
8539, 8702, 8736
SB
0
3
9998SL2
4
9998SL12
SB, SC (po wer pole adder)
0 and 1
1
9998SL22
SC
1 and 1P
3
9998SL3
1
4
9998SL13
2
3
9998SL4
4
9998SL14
9998SL24
stationary contacts, contact
springs and necessar y hardware)
SD
5
SD (power pole adder)
2
1
SE
3
2
9998SL6
3
9998SL7
SF
SG
SH
SJ
8903
4
5
6
7
2
9998SL8
3
9998SL9
2
9998SL10
3
9998SL11
2
9998SL25
3
9998SL26
2
9998SL30
3
9998SL31
9998RA5B
L (Series C) and LX (Series B)
20 A
4
SM
30 A
3
9998SL3
4
9998SL13
SP
SQ
SV
SX
SY
SZ
SJ
60 A
100 A
200 A
300 A
400 A
600 A
800 A
3
9998SL4
4
9998SL14
2
9998SL6
3
9998SL7
2
9998SL8
3
9998SL9
2
9998SL10
3
9998SL11
2
9998SL25
3
9998SL26
2
9998SL32
3
9998SL33
2
3
8910
9998SL30
9998SL31
DPA 1 p
20 A
1
9998DRC1
DPA 2 p
25 A
1
9998DRC2
DPA 3 p
30 A
1
9998DRC3
DPA 4 p
40 A
1
9998DRC4
DPA 5 p
50 A
1
9998DRC5
DPA 6 p
60 A
1
9998DRC6
DPA 7 p
75 A
1
9998DRC7
DPA 9 p
90 A
1
9998DRC9
DPA 123
120 A
1
9998DRC12
For additional infor mation, reference catalog 8502CT9701.
For other versions, please consult with your localSchneider Electric/
5/44
Square D sales office: visit www.us.telemanique.com.
NEMA Type
External auxiliary contacts
Type
Description
External conver tible contact kits
External
contact kits
For use with
Type of contact
Class
Type
NEMA size or current
8502, 8702,
SA to SJ
00 to 7
8536, 8736
8903 (Type S only) SM to SJ
30–800 A
1 N.O. contact
9999SX6
1 N.C. contact
9999SX7
2 isolated contacts 1 N.O. and 1 N.C.9999SX8
1 N.O. overlapping contact
External non-convertible contact kits
8502, 8702,
SA to SJ
00 to 7
8536, 8736
8903 (Type S only) SM to SJ
30–800 A
Catalog number
9999SX9 (1)
1 N.C. overlapping contact
9999SX10 (1)
1 N.O. contact
9999SX13
1 N.C. contact
9999SX14
2 isolated contacts 1 N.O. and 1 N.C.9999SX15
1 N.O. overlapping contact
9999SX16 (1)
1 N.C. overlapping contact
9999SX17 (1)
(1) These products must be used together and must be mounted on the same side of the contactor. They are suitable for applications where it is necessary for a N.O. contact to overlap
5
a N.C. contact.
External auxiliary contacts
Type
Description
External auxiliary contacts
External auxiliary
contacts
For use with
Class
Type
8910
DPA
DPA122/123
Type of contact
Catalog number
1 N.O. contact
9999D10
1 N.C. contact
9999D01
2 isolated contacts 1 N.O. and 1 N.C.
9999D11
2 N.O. contacts
9999D20
1 N.O. contact
9999SX6
1 N.C. contact
9999SX7
2 isolated contacts 1 N.O. and 1 N.C.
9999SX8
1 N.O. overlapping contact
9999SX9
1 N.C. overlapping contact
9999SX10
For additional information, reference catalog 8502CT9701.
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/45
NEMA Type
Industrial control relays
AC relays
(1) Standard AC control circuit voltages:
Volts
24
110
120
208
220
50 Hz
V12
V02
–
–
V03
60 Hz
V01
–
V02
V08
–
Volts
240
440
480
550
600
50 Hz
–
V06
–
V07
–
60 Hz
V03
–
V06
–
V07
Example: 8501XO20 V02.
AC Control rela y
AC Latching rela y
Continuous Load Rating
Normally Open Convertible
Basic catalog number complete with code
Basic catalog number complete with code
Inductive / resistive
Instantaneous Contacts
indicating control circuit voltage (1)
indicating control circuit voltage (1)
10 A / 10 A
0
8501XO00 ppp
–
2
8501XO20 ppp
8501XO20XL ppp
3
8501XO30 ppp
8501XO30XL ppp
4
8501XO40 ppp
8501XO40XL ppp
6
8501XO60 ppp
8501XO60XL ppp
8
8501XO80 ppp
8501XO80XL ppp
10
8501XO1000 ppp
–
12
8501XO1200 ppp
–
A maximum of 8 N.C. contacts is allowed on 9–12 pole relays.
Note: Unlatch coil is rated for intermittent duty and should be connected through a N.O. contact of the relay if the input signal is maintained. Order one more N.O. contact than
the application requires to use as a coil clearing contact.
5
DC relays
(2) Standard DC control circuit voltages:
Volts
Volts
12
24
48
72
V51
V53
V56
V58
115
125
230
250
V62
V62
V66
V66
Example: 8501XDO80V53.
DC Control relay
DC Latching relay
Continuous Load Rating
Normally Open Convertible
Basic catalog number complete with code
Basic catalog number complete with code
Inductive / resistive
Instantaneous Contacts
indicating control circuit voltage (2)
indicating control circuit voltage (2)
5A/5A
0
8501XDO00 ppp
–
2
8501XDO20 ppp
8501XDO20XDL ppp
4
8501XDO40 ppp
8501XDO40XDL ppp
6
8501XDO60 ppp
8501XDO60XDL ppp
8
8501XDO80 ppp
8501XDO80XDL ppp
Note: Unlatch coil is rated for intermittent duty and should be connected through a N.O. contact of the relay if the input signal is maintained. Order one more N.O. contact than
the application requires to use as a coil clearing contact.
For additional infor mation, reference catalog 8501CT9601.
For other versions, please consult with your localSchneider Electric/
5/46
Square D sales office: visit www.us.telemanique.com.
NEMA Type
Circuit breaker
operating mechanisms
Door mounted kits
Operating Mechanism
(includes lockout)
Complete kit
Std. shaft /std. handle
Does not include circuit breaker
Use with:
Long shaft /std. handle
Long shaft / short handle
Includes:
Includes:
Includes:
Operating mechanism
Operating mechanism
Operating mechanism
Standard 6" handle
Standard 6" handle
Short 3" handle
Standard shaft kit
Long shaft kit
Long shaft kit
Circuit breaker
Number
Frame
Catalog
Mounting depth Catalog
Mounting depth
Catalog
Mounting depth
or interrupter type
of poles
size (A)
number
min.-max. (1)
number
min.-max. (1)
number
min.-max. (1)
GJL
3
75, 100
9421LG1
5-1/2–10-1/4
9421LG4
5-1/2–20-7/8
9421LG3
5-1/2–20-7/8
FAL, FCL, FHL
2–3
100
9421LN1
5-1/2–10-7/16
9421LN4
5-1/2–21
9421LN3
5-1/2–21
KAL, KCL, KHL
2–3
250
9421LP1
6-1/4–11-3/16
9421LP4
6-1/4–21-3/4
9421LP3
6-1/4–21-3/4
LAL, LHL, Q4L
2–3
400
9421LR1
6-5/16–10-7/8
9421LR4
6-5/16–21-1/2
(3)
(3)
MEL, MXL
2–3
800
9421LT1 (2)
7-3/16–11-5/8
9421LT4 (2)
7-3/16–22-1/4
MAL, MHL
2–3
1000
9421LT1 (2)
7-3/16–11-5/8
9421LT4 (2)
7-3/16–22-1/4
(3)
NAL, NCL, NEL, NXL
2–3
1200
9421LX1 (2)
8-1/4–12-3/4
9421LX4 (2)
8-1/4–23-3/8
(3)
9421LJ1
5-1/2–10-3/4
9421LJ4
5-1/2–21-3/8
(3)
5
Merlin Gerlin® NSF, Powerpact D, H and J Circuit Breakers
MG-NSF,
3
250
Powerpact D, H and J
(1) Mounting depth measured from circuit breaker mounting surface (control panel) to outside of enclosure door in inches.
(2) Types LT1, LT4, LX1, and LX4 include an 8" handle rather than a 6" handle.
(3) 3" handles are not recommended for use with these circuit breakers .
Handles
Use With
Standard Handle Assemb lies
Special 3'' Version
Circuit breaker
Number
Frame
Type
Type
Type
Type
Type
or interrupter type
of poles
siz e (A)
1, 3R, 12
3R, 4
3R, 4, 4X
1, 3R, 12
3R, 4
Type
3R, 4, 4X
(Painted)
(Painted)
(Chrome Plated)
(Painted)
(Painted)
(Chrome Plated)
GJL
3
75
9421LH6
9421LH46
9421LC46
9421LH43
9421LH43
9421LC43
FAL, FCL, FHL
2–3
100
9421LH6
9421LH46
9421LC46
9421LH43
9421LH43
9421LC43
KAL, KCL, KHL
2–3
250
9421LH6
9421LH46
9421LC46
9421LH43
9421LH43
9421LC43
LAL, LHL, Q4L
2–3
400
9421LH6
9421LH46
9421LC46
(3)
MEL, MXL
2–3
800
9421LH8
9421LH48
9421LC48
(3)
MAL, MHL
2–3
1000
9421LH8
9421LH48
9421LC48
(3)
NAL, NCL, NEL, NXL
2–3
1200
9421LH8
9421LH48
9421LC48
(3)
(3) 3" handles are not recommended for use with these circuit breakers .
For additional information, reference catalog 9420CT9701.
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/47
NEMA Type
Disconnect switches
Variable depth and cable operated
Disconnect switches
Disconnect
switch
size
30 A
Variable
depth
mtg.
range
min.–max.
(inches)
6-5/8"–18"
Maximum horsepower ratings (1)
AC systems volts
(Motor volts)
208
240
480
(200)
(230)
(460)
7.5
7.5
15
DC
Using
2 poles
250 V
max.
5
600
(575)
20
Fuse
type
None
H, K, J, R
60 A
100 A
5
200 A
6-5/8"–18"
6-5/8"–18"
15
25
9-1/8-–19-1/4 (2) 40
15
30
60
30
60
125
50
10
75
20
150
40
Fuse clip rating
(amperes) noninterchang eable type
For Class H, J, K
or R fuses only
250 V
600 V
—
—
Switch and operating
mechanism only—
does not include
handle mechanism
Type
9421TCN30
Switch for use
with cable operators
ONLY—
does not inc lude
handle mechanism
or cab le operator
Type
9421TCN30C
Switch and operating mechanism
and handle mechanism—overpac ked
Includes Type A1
Includes Type A2
handle mechanism handle mechanism
Type
Type
9421ATCN301 9421ATCN302
30
—
9421TCF30
9421TCF30C
9421ATCF301
9421ATCF302
60
30
9421TCF33
9421TCF33C
9421ATCF331
9421ATCF332
None
—
—
9421TDN60
9421TDN60C
9421ATDN601
9421ATDN602
H, K, J, R
60
30
9421TDF60
9421TDF60C
9421ATDF601
9421ATDF602
—
60
9421TDF63
9421TDF63C
9421ATDF631
9421ATDF632
None
—
—
9421TEN10
9421TEN10C
9421ATEN101
9421ATEN102
H, K, J, R
100
100
9421TEF10
9421TEF10C
9421ATEF101
9421ATEF102
None
—
—
9421TF1
—
9421ATF11
9421ATF21
H, K, J, R
200
200
9421TF2
—
9421ATF12
9421ATF22
—
400
9421TF3 (3)
—
9421ATF13 (3) 9421ATF23 (3)
400 A
11.38
Fixed Depth(4) (A5 or A6 Handle)
75
125
250
350
50
None
—
—
9421TG1 (6)(7)
—
For handle selection,
see table below.
400 A
15.87–19 (5)
Adj. Depth (4) (A7 or A8 Handle)
75
125
250
350
50
H, K, J, R
400
400
9421TG2 (6)(7)
—
For handle selection,
see table below.
(1) Refers to r ating of switch only.
(2) 9422 R2 will extend maximum mounting depth 7"
(3) Accommodates Class J fuses only.
(4) Switches are either fixed-depth or adjustable; the handle will determine installation.
(5) In steps of 0.63 inches.
(6) Commercially available enclosures may not accept type TG operating mechanisms. Contact enclosure man ufacturer for availability of enclosures for use with these
switches.
(7) Right hand flange mounting only.
Cable operator and handles
Disconnect
Switch Types
Switch Size
30 A, 60 A, 100 A
Cable Mechanisms (8)
Cable Mechanisms with A1 Handle
for Types 1, 3, 3R, 4 and 12
Catalog number
Catalog number
36"
9421CFT30
9421CFT31
48"
9421CFT40
–
60"
9421CFT50
9421CFT51
120"
9421CFT10
9421CFT11
Cable
Length
TCF, TCN, TDF, TDN, TEF, TEN
(8) Must purchase handle mechanism separately (9422, A1, A2, A3 or A4).
Handle NEMA Type Enclosure
1, 3, 3R, 4 (sheet steel), 12
4, 4X (stainless steel) (10)
Type of Handle
Catalog number
Catalog number
6" HANDLE (9)
9421A1
9421A2
4" HANDLE (9)
9421A3
9421A4
12" HANDLE (fixed depth) (11)
9421A5
9421A6
12" HANDLE (variable depth) (11)
9421A7
9421A8
10" HANDLE (12)
9421A9
9421A10
(9) For use with 30–200 Ampere switches and all circuit breaker mechanisms.
(10) All exter nal metal parts are either stainless steel or a chrome-plated non-ferrous die casting.
(11) For use with 400 Ampere Type TG1 and TG2 disconnect switches ONLY.
(12) For use with Type D2 remote or dual adaptor kit.
For additional information, reference catalog 9420CT9701.
For other versions, please consult with your localSchneider Electric/
5/48
Square D sales office: visit www.us.telemanique.com.
NEMA Type
Circuit breaker
operating mechanisms
Flange mounted
Use with:
Operating mechanism
Circuit breaker
Number
Frame
Variable depth
Operating mechanism onl y —
Operating mechanism and handle mechanism
frame size
of poles
size (A)
mtg. range (In.)
does not include
Includes Type A1 (2)
Includes Type A2 (2)
min.-max. (1)
handle mechanism
handle mechanism
handle mechanism
Square D circuit breakers
GJL
3
100
6.00–17.75
9422RG1
9422ARG11
9422ARG21
FAL, FHL
2–3
100
5.38–17.75
9422RN1
9422ARN11
9422ARN21
KAL, KHL
2–3
250
6.38–17.88
9422RP1
9422ARP11
9422ARP21
LAL, LHL, Q4L
2–3
400
7.44–18.25
9422RR1
9422ARR11
9422ARR21
9422ART21
MEL, MXL
2–3
800
9.00–18.38
9422R T1
9422ART11
MAL, MHL
2–3
1200
9.00–18.38
9422RT1
9422ART11
9422ART21
NAL, NCL, NEL, NXL
2–3
1200
11.00–18.37
9422RX1
–
–
Merlin Gerin NSF, NSJ, Powerpact D, Hand J Circuit Breakers
MG-NSF,
Powerpact D, Hand J
3
250
5.88–17.75
9422RQ1
–
–
MG-NSJ
3
600
9.00–17.75
9422RS1
–
–
5
(1) Class 9422 Type R2 will extend mounting depth 7 inches.
(2) For handle information, see page 5/48.
Cable operators
Cable operators
Circuit breaker
No. of
type
poles
GJL
3
FAL, FHL
KAL, KHL
LAL, LHL, Q4L
2-3
2-3
2-3
Frame size
Cable length
Cable mechanism
Cable mechanisms with A1 handle
100
36"
9422CGJ30
9422CGJ31
48"
9422CGJ40
9422CGJ41
60"
9422CGJ50
9422CGJ51
120"
9422CGJ10
9422CGJ11
36"
9422CFA30
9422CFA31
9422CFA50
9422CFA51
9422CFA10
9422CFA11
f orTypes 1, 3, 3R, 4, 12 (1)
100
250
400
36"
9422CKA30
9422CKA31
60"
9422CKA50
9422CKA51
9422CKA11
120"
9422CKA10
36"
9422CLA30
9422CLA31
60"
9422CLA50
9422CLA51
120"
9422CLA10
9422CLA11
36”
9422CSF30
–
Powerpact D,
60"
9422CSF50
–
Hand J
84"
9422CSF70
–
120"
9422CSF10
–
MG-NSF,
MG-NSF,
3
36”
9422CSF304
–
Powerpact D,
60"
9422CSF504
–
Hand J
120"
9422CSF104
–
36”
9422CSJ30
–
60"
9422CSJ50
–
120"
9422CSJ10
–
36”
9422CSJ304
–
60"
9422CSJ504
–
120"
9422CSJ104
–
MG-NSJ
MG-NSJ
4
250
3
4
250
600
600
For additional information, reference catalog 9420CT9701.
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
5/49