MA-COM 1-1393230-1

General Purpose Relays
Special Load PCB Relay RP 3 SL
I
1 pole 16 A, 1 NO contact
I
For high inrush currents,
I
120 A / 20 ms inrush peak current
I
Mono- or bistable
I
4 kV / 8 mm coil-contact
I
RoHS compliant (Directive 2002/95/EC)
as per product date code 0404
Applications
Lighting control, timers, motor control, building automation
F0147-A
Approvals
V
REG.-Nr. 3736 (DC versions only), Z E214024, H 2011340.05 (DC vers. only)
Technical data of approved types on request
Contact data
Contact configuration
Contact set
Type of interruption
Rated current
Rated voltage / max.switching voltage AC
Limiting continuous current
Maximum breaking capacity AC
Limiting making capacity, max 4 s, duty factor 10%
peak value, max 20 ms
Contact material
Mechanical endurance DC
bistable
Rated frequency of operation with / without load
Contact
Type
RP3SL
RP3SL
1 NO
single contact
micro-disconnection
16 A
240/400 VAC
16 A
4000 VA
25 A
120 A
AgSnO2
> 20x106 cycles
> 1x 106 cycles
16 / 1200 min-1
ratings
Load
16 A, 250 VAC, 70°C, 16 min-1, IEC61810-1
12 A, 250 VAC, 70°C, 16 min-1, IEC61810-1
Cycles
5x104
1x105
Coil data
Coil data, monostable coil
Rated coil voltage range
Coil power
Operative range RTII / RTIII
5...110 VDC
typ 520 mW
2/1
Coil versions, DC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
c
mW
+10%
012
12
9.0
1.2
270+
533
+15%
024
24
18.0
2.4
1100+
524
048
48
36.0
4.8
4400+15%
524
060
60
45.0
6.0
6540+15%
550
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays
Special Load PCB Relay RP 3 SL (Continued)
Coil data, bistable coils
Rated coil voltage range
Coil power
Operative range
Reset voltage minimum / maximum, % of Urtd
Minimum energization duration
Maximum energization duration
1 coil
2 coils
5...24 VDC
typ 1,25 W
1
70% / 110%
75% / 120%
20 ms
1 min at < 50% DF
Coil versions, bistable DC-coil
Coil
Rated
Operate
Reset
Reset
Coil
Rated coil
code
voltage
voltage
voltage
R1
resistance
power
VDC
VDC
VDC
c/W
c
mW
bistable, 1 coil
A05
5
3.7
3.6
39/0.5
21+10%
1190
A12
12
9.0
8.7
220/0.5
115+10%
1252
A24
24
18.0
16.7
820/0.5
460+10%
1252
bistable, 2 coils
F12
12
9.0
9.0
105+15%
1371
F24
24
18.0
18.0
460+15%
1252
All figures are given for coil without preenergization, at ambient temperature +23°C, duty
factor 20%. Other coil voltages on request
Circuit scheme for bistable 1 coil
Insulation
Dielectric strength coil-contact circuit
open contact circuit
Clearance / creepage coil-contact circuit
Material group of insulation parts
Tracking index of relay base
Insulation to IEC 60664-1
Type of insulation coil-contact circuit
open contact circuit
Rated insulation voltage
Pollution degree
Rated voltage system
Overvoltage category
4000 Vrms
2000 Vrms
W 8 / 8 mm
W IIIa
PTI 250 V
basic
functional
250 V
3
240 V
2
400 V
III
PCB layout / terminal assignment
Bottom view on solder pins
Other data
RoHS - Directive 2002/95/EC
compliant as per product date code 0404
Flammability class according to UL94
V-2
Ambient temperature range RTII - flux proof
-40...+70°C
RTIII - wash tight
-40...+35°C
Operate- / release time DC coil
typ 8 / 2 ms
Operate- / reset time bistable coils
typ 6 / 2 ms
Bounce time
typ 2 ms
Vibration resistance (function), opening of closed contact
20 g
Shock resistance (destruction)
100 g
Category of protection
RTII - flux proof, RTIII - wash tight
Mounting
pcb or on socket
Mounting distance 12A / 16A
0 / 3 mm
Resistance to soldering heat flux proof version
270 °C / 10 s
wash tight version
260°C / 5 s
Relay weight
18 g
Packaging unit monostable, bistable 1 coil
20 / 500 pcs
bistable 2 coils
100 pcs
Accessories
For monostable and bistable 1 coil version, details see
accessories RT
S0163-CR
S0163-CS
Bistable versions:
Indicated contact position during or after coil
energization with reset voltage.
2-coil versions:
Operate A2, A3
Reset A1, A3
b) for 2 coil version only
2
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays
Special Load PCB Relay RP 3 SL (Continued)
Dimensions
S0273-BC
Product key
R P
Type
Version
3 flux proof
7
Contact configuration / contact material
SL 1 NO contact, AgSnO2
Coil
Coil code: please refer to coil versions table
Preferred types in bold print
Product key
RP3SL005
RP3SL012
RP3SL024
RP3SLA12
RP3SLA24
RP3SLF12
RP3SLF24
RP7SL012
RP7SL024
Version
16 A
flux proof
wash tight
Contacts
1 NO contact
AgSnO2
16 A
wash tight
S L
Coil
DC-coil
bistable
1-coil
bistable
2-coils
DC-coil
Coil
5 VDC
12 VDC
24 VDC
12 VDC
24 VDC
12 VDC
24 VDC
12 VDC
24 VDC
Part number
0-1393230-7
0-1393230-9
1-1393230-1
0-1393230-3
0-1393230-4
0-1393230-5
0-1393230-6
6-1393231-5
6-1393231-6
3
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.